Safety and Warranty

This label indicates a flammable refrigerant “R290” used. There is a risk of fire.

WARNING AND SAFETY INSTRUCTION

This product cannot be used in outdoor environment.

This ice machine is not intended for use by children, and those with physical weakness, slow 

response, or mental disorders.

•  The installation, repair or maintenance of this ice machine must be carried out by professional and qualified 

personnel, or electric shock, fire, personal injury may cause from incorrect operation.

• 

After the ice machine is delivered, please keep the machine still upright for more than 24 hours, to have the 

lubricant be fully precipitated before startup, otherwise the compressor may be damaged.

• 

When handling, keep the cabinet upright, with the inclination not exceeding 45 degrees. Do not invert the 

machine or lay it horizontally.

• 

This ice machine should not be placed in wet or easily splashed area.

• 

The grounding of this ice machine cannot be connected to gas pipe, water pipe, telephone line or lightning 

rods, etc.

• 

There are rotating components in this ice machine. Do not insert slim objects into ventilation or exhaust 

ports, or serious mechanical injury may occur.

•  Do not store volatile or flammable substances in this ice machine, or it may result in explosion or fire.

• 

Do not store any sundries, or freeze any food in the ice bin. Keep the ice scoop clean.

•  The ice machine must be placed on the floor sufficient to supports its weight. Insufficient base may cause 

the equipment fall over and cause injury.

•  There should be sufficient ventilation space around the ice machine. Keep good ventilation.

•  Only the power supply specified on the machine nameplate can be used with this ice machine.

• 

This ice machine cannot be connected to hot water.

• 

Socket for this ice maker must be reliably grounded and with leakage protection.

• 

The ice machine must be disconnected from power before manual cleaning, repairing and maintenance.

• 

Before cleaning, repairing and maintenance, the remaining ice in the ice bin should be removed from the 

ice machine to avoid contamination to ice.

• 

Do not splash water directly onto the surface of the ice machine during the cleaning process; otherwise it 

may cause short circuit, leakage or other faults.

• 

Flammable foaming agent is used during the foaming process. The ice maker should be disposed of and 

recycled by qualified personnel and institutions.

• 

The ice machine should be properly managed to ensure that children will not play with the machine.

•  When the ice machine malfunctions, turn off the power and contact professional personnel for repairing

For the ice maker with flammable refrigerant R290:

•  DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. DO NOT USE 

Содержание IC-CN-0529

Страница 1: ...Revised 12 17 2020 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Ice Maker Model IC CN 0529 Item 46452 Instruction Manual...

Страница 2: ...19 20 22 23 Table of Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schemati...

Страница 3: ...AMAGES DUE TO WATER LEAKS WARRANTY FOR WATER LEAKS IS VOID IF THE WICKING PAD IS NOT REPLACED EVERY SIX MONTHS AND IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIAN...

Страница 4: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 5: ...mientras esta en el funcionamiento REVISE EL PAQUETE A SU LLEGADA Tras la recepcion de un envio Omcan favor inspeccionar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton...

Страница 6: ...a hazardous voltage There is a risk of electric shock This label indicates a hazardous voltage There is a risk of electric shock This label indicates rotating components inside There is a risk of ser...

Страница 7: ...result in explosion or fire Do not store any sundries or freeze any food in the ice bin Keep the ice scoop clean The ice machine must be placed on the floor sufficient to supports its weight Insuffici...

Страница 8: ...ill start properly When the ice cubes fill up the ice bin the machine will automatically stop The ice machine is generally used in the following and similar occasions The kitchen area of a store offic...

Страница 9: ...er source potable water with water pressure from 1 3 Bar to 5 5 Bar water temperature 5 35 C The ice machine should be kept away from heat sources and should be strictly forbidden to use at extremely...

Страница 10: ...nnect the drain pipe to the drain connection In order to meet a good draining it is recommended that the drain pipe should have a difference of level more than 3cm per meter and confirm that the drain...

Страница 11: ...maker will do self check and pump out remaining water Preparing after the ice machine is energized the inlet valve opens and water will come inside the machine until it reaches high level Ice making...

Страница 12: ...minutes 4 Cleaning During the normal operation hold the cleaning button for 3 seconds to enter the cleaning process During the entire cleaning process cleaning agents and disinfectants need to be put...

Страница 13: ...nce INLET WATER FILTER The filter element should be inspected regularly It is recommended to replace filter element every month to every 3 months INTERIOR CLEANING The inside of the ice storage bin ca...

Страница 14: ...t 15 minutes Please do spray sterilizing to the evaporator at the mean time to insure a complete sterilizing When finished the ice maker will get into rinsing process the process will take about 5 min...

Страница 15: ...t the defrosting valve Ice thickness too thin or too thick Check and correct ice thickness setting Poor transparency of ice cubes ice cubes too thin or incomplete Ice thickness too thin Check and corr...

Страница 16: ...water curtain is reset E03 Ice Harvest Overtime Sleeping mode E04 High Temp Fault Sleeping mode E05 Water Shortage Fault Sleeping mode and retry every 30 mins E06 Over Pressure Fault Sleeping mode E07...

Страница 17: ...17 Parts Breakdown Model IC CN 0529 46452...

Страница 18: ...t Panel for 46452 27 AC879 Expansion Valve for 46452 8 AC889 Spray Pipe for 46452 18 AC899 Door Plastic End Cap for 46452 28 AC880 High Voltage Switch for 46452 9 AC890 Evaporator for 46452 19 AC881 D...

Страница 19: ...19 Model IC CN 0529 46452 Electrical Schematics...

Страница 20: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 21: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 22: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 23: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 24: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: