Omcan FW-CN-0024 Скачать руководство пользователя страница 6

6

Installation

SET UP

1. 

Remove all packing material and tape, as well as any protective plastic from the equipment.

2. 

Place the equipment in the desired position and height.

3. 

Clean and dry the equipment thoroughly before using.

INSTALLATION

The installation of this equipment must conform with local codes, or with the National Gas Code, ANSIZ223.1/

NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.

•  The equipment and its individual shutoff valve must be disconnected from the gas supply piping system 

during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).

•  The equipment must be isolated from the gas supply piping system by closing its individual manual shutoff 

valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ 

psi (3.5 kPa).

CLEARANCE AND POSITIONING AROUND THE EQUIPMENT:

•  This equipment must be installed adjacent to non-combustible surfaces only with a minimum spacing of 6” 

from all sides. This equipment must be a distance of 6” from other equipment. The equipment must have 

the 4” legs installed and be placed on a noncombustible surface.

AIR SUPPLY AND VENTILATION:

•  The area in front and around the equipment must be kept clear to avoid any obstruction of the flow of 

combustion and ventilation air.

•  Adequate clearance must be maintained at all times in front of and at the sides of the equipment for 

servicing and proper ventilation.

Technical Specifications

Model

FW-CN-0024

FW-CN-0036

FW-CN-0048

BTU per Hour

20,000

30,000

40,000

Dimensions

24” x 29” x 23”

607 x 480 x 592mm

36” x 29” x 23”

912 x 480 x 592mm

48” x 29” x 23”

1217 x 480 x 592mm

Packaging Dimensions

30” x 25” x 30”

770 x 640 x 770mm

42.5” x 25” x 30”

1080 x 640 x 770mm

54” x 25” x 30”

1380 x 640 x 770mm

Weight

101 lbs. / 46 kgs.

139 lbs. / 63 kgs.

185 lbs. / 84 kgs.

Packaging Weight

145.5 lbs. / 66 kgs.

196 lbs. / 89 kgs.

251 lbs. / 114 kgs.

Item Number

44411

44412

44413

Содержание FW-CN-0024

Страница 1: ...Revised 01 20 2020 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Cheese Melters Models FW CN 0024 0036 0048 Items 44411 44412 44413 Instruction Manual ...

Страница 2: ...14 15 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Registration Model FW CN 0024 Model FW CN 0036 Model FW CN 0048 ...

Страница 3: ...utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication et distribution Companie Limité et Food Machinery d Amerique dba Omcan et Omcan Inc ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipemen...

Страница 4: ...a y ésta usando ropa apropiada y autorizada Cualquier modificación a la máquina anúla la garantía y puede causar daños a las personas usando la máquina mientras esta en el funcionamiento REVISE EL PAQUETE A SU LLEGADA Tras la recepcion de un envio Omcan favor inspeccionar daños externos Si no hay daños evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solic...

Страница 5: ... gas lines on this equipment will damage the valve and affect its operation If you smell gas follow the instructions provided by the gas supplier Do not touch any electrical switch do not try to light the burner do not use a telephone within close proximity Never attempt to move grates while cooking 1 YEAR PARTS AND LABOR WARRANTY Within the warranty period contact Omcan Inc at 1 800 465 0234 to s...

Страница 6: ...ITIONING AROUND THE EQUIPMENT This equipment must be installed adjacent to non combustible surfaces only with a minimum spacing of 6 from all sides This equipment must be a distance of 6 from other equipment The equipment must have the 4 legs installed and be placed on a noncombustible surface AIR SUPPLY AND VENTILATION The area in front and around the equipment must be kept clear to avoid any obs...

Страница 7: ...t s are level and properly spaced on the wall so that they will align with the mounting bracket on the rear of the cheesemelter frame 2 Attach the wall mount bracket s to the wall with suitable fasteners not supplied to match the on site construction 48 60 and 72 models will have two wall mount brackets 3 Hang the cheesemelter from its built in mounting bracket onto the wall mounting brackets GAS ...

Страница 8: ...when the burner valve is turned to the highest setting Access to the pilot flame adjustment screw is obtained through the holes in the front panel OPERATION Before initial use turn the gas control knob to the maximum setting and allow the equipment to burn in for 20 minutes Seeing smoke coming from the cooking chamber is normal during burn in After 20 minutes of burn in equipment is ready for use ...

Страница 9: ... for Service Maintenance 5 Empty and clean the drip tray MAINTENANCE A qualified service company should check the unit for safe and efficient operation on an annual basis Gas piping shall be a certain size and installed to provide a supply of gas sufficient to meet the full gas input of the equipment A manual shut off valve should be installed upstream from the manifold within 4 ft 1 2m of the equ...

Страница 10: ...urer Model Number 44411 FW CN 0024 Cheese Melter 24 Natural Gas 20 000 BTU cETLus ETL Sanitation RCM 24 44412 FW CN 0036 Cheese Melter 36 Natural Gas 30 000 BTU cETLus ETL Sanitation RCM 36 44413 FW CN 0048 Cheese Melter 48 Natural Gas 40 000 BTU cETLus ETL Sanitation RCM 48 ...

Страница 11: ...11 Parts Breakdown Model FW CN 0024 44411 Model FW CN 0036 44412 Model FW CN 0048 44413 ...

Страница 12: ... 2 AC318 Pilot Valve for RCM 36 10 AC335 30 000 BTU Burner for RCM 36 16 AC330 Gas Venturi Pipe for RCM 36 3 AC319 Control Valve for RCM 36 11 AC336 Housing for RCM 36 17 AC315 Knob Assembly for RCM 36 4 6 AC332 Adaptor for RCM 36 12 AC337 Oil Collector for RCM 36 18 66208 Pilot for RCM 36 7 AC333 Flexi Pipe for RCM 36 13 AC338 Front Panel for RCM 36 19 AC331 Pilot Pipe for RCM 36 8 AC334 Nozzle C...

Страница 13: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Страница 14: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Страница 15: ...gister online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer from which Purchased Butcher Supermarket Catere...

Страница 16: ...s relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Amérique du Nord Europe Asie et Amérique du Sud nous travaillons continuellement à améliorer et développer l entreprise Nous nous efforçons d offrir à nos clients une valeur exceptionnelle grâce à nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 5000 produ...

Отзывы: