6
Installation
SET UP
1.
Remove all packing material and tape, as well as any protective plastic from the equipment.
2.
Place the equipment in the desired position and height.
3.
Clean and dry the equipment thoroughly before using.
INSTALLATION
The installation of this equipment must conform with local codes, or with the National Gas Code, ANSIZ223.1/
NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
• The equipment and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa).
• The equipment must be isolated from the gas supply piping system by closing its individual manual shutoff
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½
psi (3.5 kPa).
CLEARANCE AND POSITIONING AROUND THE EQUIPMENT:
• This equipment must be installed adjacent to non-combustible surfaces only with a minimum spacing of 6”
from all sides. This equipment must be a distance of 6” from other equipment. The equipment must have
the 4” legs installed and be placed on a noncombustible surface.
AIR SUPPLY AND VENTILATION:
• The area in front and around the equipment must be kept clear to avoid any obstruction of the flow of
combustion and ventilation air.
• Adequate clearance must be maintained at all times in front of and at the sides of the equipment for
servicing and proper ventilation.
Technical Specifications
Model
FW-CN-0024
FW-CN-0036
FW-CN-0048
BTU per Hour
20,000
30,000
40,000
Dimensions
24” x 29” x 23”
607 x 480 x 592mm
36” x 29” x 23”
912 x 480 x 592mm
48” x 29” x 23”
1217 x 480 x 592mm
Packaging Dimensions
30” x 25” x 30”
770 x 640 x 770mm
42.5” x 25” x 30”
1080 x 640 x 770mm
54” x 25” x 30”
1380 x 640 x 770mm
Weight
101 lbs. / 46 kgs.
139 lbs. / 63 kgs.
185 lbs. / 84 kgs.
Packaging Weight
145.5 lbs. / 66 kgs.
196 lbs. / 89 kgs.
251 lbs. / 114 kgs.
Item Number
44411
44412
44413