DRY OPERATION WITH COVER

1.  Plug unit into appropriate electrical power supply receptacle.

2.  With openings covered, set dial on highest position for 45 minutes to preheat unit.

3. 

During initial start up, smoke or odor may be detected (a small amount). This will occur when the coating 

on the heating element burns off and should stop approximately a half hour after start up.

4. 

Place precooked food (minimum 160°F) in food pans, place in openings and cover with lids. (Indicator light 

is the set point for the control knob).

5.  Adjust to desired setting for proper food temperature. This will vary with the type of food, size of pans and 

individual serving temperatures. NSF requires food to be a minimum of 150°F.

6.  To increase temperature, turn knob toward highest setting. To decrease, turn toward lowest setting.

7.  Food pans should be covered to maintain temperature when food is not being served and to prevent food 

from drying out.

WET OPERATION WITH COVER (SPILLAGE PANS REQUIRED)

NOTE: DO NOT put hot water in heating well or on element.

1.  With openings covered, set dial at highest setting for 45 minutes.

2. 

Install spillage pans and spillage pans to bottom of food pans with hot water (minimum of 185°F).

3. 

Place pre-cooked food (minimum 160°F) in food pans.

4.  Place in spillage pans and cover food pans with lids.

5. 

Adjust to desired setting for proper food temperature. NSF requires food to be a minimum of 150°F.

CLEANING

NOTE: To maintain cleanliness and increase service life, the steam table should be cleaned daily. Do 

not immerse the unit in water or any other liquid. If liquid enters the electrical compartment, it may 

cause a short circuit or electrical shock.

1.  Allow unit to completely cool before cleaning.

2.  Disconnect the cord from the outlet.

3.  Wipe the inside and outside surfaces of the unit with a damp cloth, then wipe dry.

4.  To avoid damage, do not use abrasive cleaners or scouring pads.

5.  Avoid using cleaners as the chemical residue could damage or corrode the surfaces of the unit. Clean the 

unit with warm soapy water and soft cloth only.

Содержание FW-CN-0002-H

Страница 1: ...od Warmers Models FW CN 0002 H 0003 H 0004 DH 0005 FH Items 46646 46574 46647 46648 Instruction Manual Revised 09 25 2020 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan co...

Страница 2: ...tents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Parts Breakdown Electrical Schematics Notes Warranty Registration Model FW CN 0002 H M...

Страница 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 4: ...y autorizada Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el funcionamiento REVISE EL PAQUETE A SU LLEGADA Tras la recep...

Страница 5: ...d power supply is adequate for continual usage and the voltage is correct 1 YEAR PARTS AND LABOUR WARRANTY Within the warranty period contact Omcan Inc at 1 800 465 0234 to schedule an Omcan authorize...

Страница 6: ...Model FW CN 0002 H FW CN 0003 H FW CN 0004 DH FW CN 0005 FH Maximum Temperature 100 C 212 F Power 2000W 3000W 4000W 5000W Electrical 208V 240V 60Hz Current 7 21A 10 82A 14 42A 18 03A Pan Capacity 2 Fu...

Страница 7: ...om drying out WET OPERATION WITH COVER SPILLAGE PANS REQUIRED NOTE DO NOT put hot water in heating well or on element 1 With openings covered set dial at highest setting for 45 minutes 2 Install spill...

Страница 8: ...cluded HN 2 240 46574 FW CN 0003 H Three Pans Electric Steam Table with Undershelf 3000W 208 240V 60Hz 1 cETLus ETLs Pan Not Included HN 3 240 46647 FW CN 0004 DH Four Pans Electric Steam Table with U...

Страница 9: ...9 Parts Breakdown Model FW CN 0002 H 46646 Model FW CN 0003 H 46574 Model FW CN 0004 DH 46647 Model FW CN 0005 FH 46648...

Страница 10: ...2 240 13 AD167 Thermostat Knob for HN 2 240 5 AD172 Shelf for Cutting Board 2 Well for HN 2 240 9 AD177 Terminal Block for HN 2 240 15 Item No Description Position Item No Description Position Item No...

Страница 11: ...Shelf for Cutting Board 4 Well for HN 4 240 9 AD177 Terminal Block for HN 4 240 15 Item No Description Position Item No Description Position Item No Description Position AD163 Adjustable Foot for HN...

Страница 12: ...12 Model FW CN 0002 H 46646 Electrical Schematics...

Страница 13: ...13 Electrical Schematics Model FW CN 0003 H 46574...

Страница 14: ...14 Model FW CN 0004 DH 46647 Electrical Schematics...

Страница 15: ...15 Electrical Schematics Model FW CN 0005 FH 46648...

Страница 16: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 17: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: