Omcan FR-CN-1200-D Скачать руководство пользователя страница 7

8

Maintenance

Troubleshooting

3. 

Take out the filter.

CHECK FOR LEAKS

Observe all connectors and welding joints for oil stains. This indicates that there is a leak, please call Omcan if 
you notice any oil stains.

ALWAYS OBSERVE THE OPERATION OF THE UNIT, IN THE EVENT OF ANY ABNORMAL SOUNDS OR 
SMELLS, OR IF THE UNIT BEGINS TO SMOKE, DISCONNECT THE UNIT FROM THE POWER SUPPLY 
AND CALL OMCAN.

Trouble

Causes

Solutions

Strange noise under the 
bottom shelf.

Fan blade broken.

Power off and fix the blade.

Non-refrigerating in spite of 
normal operation.

Unit off.

Power on.

Melting process.

Stop melting.

Refrigerant leaking.

Patch the leak and refill refrigerant.

Unit failure.

Call Omcan.

Weak air from air curtain, 
and higher cabinet 
temperature.

Evaporator blocked by frost.

Increase melting frequency.

Inside fan damaged.

Replace the fan.

Too low point of temperature 
controller.

Adjust the set point.

Vent blocked by storage.

Remove the storage.

Normal air curtain, but 
higher cabinet temperature.

Insufficient refrigerant.

Refill the refrigerant.

Too high set point of temperature 
controllers.

Adjust the set point for the 
temperature controller.

The wind curtain disturbed by strong 

air flow.

Removing the disturbing factors.

Ambient temperature or humidity 
beyond standards.

Improve the conditions.

Melting water overflows.

Heating pipe for melting water 

damaged.

Replace the heating pipe.

Water level controller failure.

Replace the water level controller.

Ambient temperature or humidity 
beyond standards.

Improve the conditions.

Содержание FR-CN-1200-D

Страница 1: ...le of Contents Section General Information Safety and Warranty Technical Specifications Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Registration Model FR...

Страница 2: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 3: ...Cualquier modificaci n a la m quina an la la garant a y puede causar da os a las personas usando la m quina mientras esta en el funcionamiento REVISE EL PAQUETE A SU LLEGADA Tras la recepcion de un e...

Страница 4: ...ground No shared power outlets Refrigerator cable should never share the power outlet with any other appliance as cable will overheat and may result in a fire Protect cables Extra caution should be u...

Страница 5: ...Item Number 43118 Safety and Warranty WARNING The packaging components are classified as normal solid urban waste and can therefore be disposed of without difficulty In any case for suitable recycling...

Страница 6: ...press again to turn off Manual start stop defrost Press button and hold for 6 seconds to either defrost or to stop defrost 4 Refrigeration LED During refrigeration the LED is on When the cold room tem...

Страница 7: ...it failure Call Omcan Weak air from air curtain and higher cabinet temperature Evaporator blocked by frost Increase melting frequency Inside fan damaged Replace the fan Too low point of temperature co...

Страница 8: ...er failure Replace the temperature controller NOTE Following occurrences are not problems The murmur of water is heard when the refrigerator is working It is a normal occurrence as the coolant is circ...

Страница 9: ...10 Parts Breakdown Model FR CN 1200 D 43118...

Страница 10: ...52 Front Baffle for ARD600L 14 62882 Door Glass for ARD600L 44 62911 Thermostat for ARD600L 74 62853 Front Baffle Glass Fixing Strip for ARD600L 15 62883 Type A Seal for ARD600L 45 62912 Switch for AR...

Страница 11: ...12 Electrical Schematics Model FR CN 1200 D 43118...