11
Instructions for Field Conversion between LP & NG
Setting the pilot burner:
When changing from natural gas to LPG it is necessary to adjust the pilot burner flame as well. This is done in
the following steps:
1. Remove the control knobs from the front of the unit, loosen the screws holding the front panel and remove.
2. The pilot burner valve is positioned to the right of the control valve, a small adjustment screw is located on
the front face of the valve body. This can be turned in or out with a small flat screw driver.
3. Adjust the screw in small increments whilst the pilot flame is burning until a small stable flame is achieved.
4. Replace the front panel and secure, refit the control knobs.
Fig 4. Gas Pressure Regulator
Fig 5. Conversion