OPERATOR TROUBLESHOOTING

The tables that follow provide operators with a list of possible malfunctions, the probable causes of the 

malfunctions, and the corrective actions to take to correct the problem.

In some cases the operator may not be able to correct the problem, but will at least be able to accurately 

diagnose the problem, and that will assist a qualified service technician in restoring the equipment to full 

operation in the shortest possible time.

Problem

Probable Cause

Corrective Action

Burner does not light at all.

Pilot is not lit.

Light pilot.

Loose, dirty, or corroded terminals 

on gas valve.

Clean and tighten terminals on gas 

valve.

Loose, dirty, or corroded terminals 

on thermostat.

Clean and tighten terminals on 

thermostat.

Burner does not light all the way 

around.

One or more burner orifices 

clogged.

Turn gas valve knob to OFF 

position. Use thin wire to clear 

obstruction from burner orifices.

Blocked flue.

Clear blockage from flue.

Burner experiences delayed 

ignition.

Too little make-up air in kitchen.

Adjust kitchen ventilation system to 

increase make-up air.

Flame rolling out from under 

noodle cooker.

Flue obstructed.

Remove obstruction from flue.

Содержание CE-CN-0011-NG

Страница 1: ...Pasta Cookers Models CE CN 0011 NG 0022 NG Items 47714 48000 Instruction Manual Revised 02 01 2024 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com...

Страница 2: ...16 17 18 19 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Registration Mo...

Страница 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 4: ...nar da os externos Si no hay da os evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en la m qu...

Страница 5: ...trolling thermostat fails This unit was carefully inspected and packed before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of the equipm...

Страница 6: ...ker carefully for visible or concealed damage CLEARANCE AND VENTILATION The cooker s must be installed with a 6 150mm clearance at both sides and back when installed adjacent to combustible constructi...

Страница 7: ...xible gas hose is used a restraining cable must be connected at all times when the cooker is in use The restraining cable and installation instructions are packed with the flexible hose in the accesso...

Страница 8: ...burner manifold pressure be checked at this time by the local gas company or an authorized service agent Refer to check burner manifold pressure in this manual for the proper procedure WATER AND GAS C...

Страница 9: ...t temperature The thermostat controls the water tank temperature by regulating the gas supply to the burner via the gas valve The thermostat is in the full OFF position when the word OFF is at the top...

Страница 10: ...PARTS AND ACCESSORIES Wipe all detachable parts and accessories with a clean cloth dampened with a detergent solution Rinse and thoroughly dry each part SEMI ANNUAL CHECKS AND SERVICE CHECK BURNER MAN...

Страница 11: ...ble Cause Corrective Action Burner does not light at all Pilot is not lit Light pilot Loose dirty or corroded terminals on gas valve Clean and tighten terminals on gas valve Loose dirty or corroded te...

Страница 12: ...inserted fully into pilot burner Reinsert pilot generator into pilot burner until flame surrounds tip Corroded connection where pilot generator connects to gas valve Clean pilot generator connection...

Страница 13: ...13 Parts Breakdown Model CE CN 0011 NG 47714...

Страница 14: ...for 47714 11 AO146 Clamp for 47714 33 AP150 Overflow Pipe for 47714 55 AP122 Overflow Strainer Mesh for 47714 12 AP133 Water Feeding Pipe for 47714 34 AP151 Pipe Clamp for 47714 56 AP123 Basket Suppo...

Страница 15: ...15 Parts Breakdown Model CE CN 0022 NG 48000...

Страница 16: ...58 AP119 Overflow Box for 48000 12 AC316 Pilot Pipe for 48000 36 AP151 Pipe Clamp for 48000 59 AP120 Heat Deflector for 48000 13 AO146 Clamp for 48000 37 AP149 Water Outlet Pipe Connector Drain Pipe f...

Страница 17: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: