background image

12

Operation

Maintenance

FRY BASKET CAPACITY

Recommended pounds per basket are 1.5 lbs. (0.7 kg).

EXTENDING SHORTENING LIFE

Shortening life can be extended by the following guidelines:

• 

Do not salt foods over the fryer.

•  Use good-quality shortening.

•  Filter shortening daily (at a minimum).

•  Replace shortening if it becomes poorly flavored.

•  Keep equipment and surrounding clean.

• 

Set thermostat correctly.

•  Remove excess moisture and particles from food products before placing in fryer.

DRAINING THE TANK

WARNING Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the 

fryer.

WARNING Spilling hot frying compound can cause severe burns. Do not move the fryer without 

draining all frying compound from the tank.

1. 

Turn the thermostat to OFF.

2. 

Turn the gas valve to OFF.

3. 

Let the shortening cool completely before draining.

4.  Direct the drain spout into the container that you want to drain the shortening into.

5.  Open the drain valve. The oil will drain into the container. When the container is full or the fryer tank is 

empty, close the drain valve. Repeat this step until the fryer is empty.

6. 

If desired, perform routine clean-out as described under CLEANING.

7. 

Once tank is completely clean and empty, add new shortening and set thermostat to desired temperature.

FILTERING

WARNING Hot oil and hot parts can cause burns. Use care when operating, cleaning, and servicing the 

fryer.

•  Filter shortening as required. Refer to the instructions provided with your filtering equipment.

Содержание 47354

Страница 1: ...Revised 09 22 2022 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Gas Fryers Models CE CN OF LP DOF LP Items 47354 47355 Instruction Manual...

Страница 2: ...15 17 18 19 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Notes Warranty Registration Mo...

Страница 3: ...e It s of the utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required...

Страница 4: ...xterior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpe...

Страница 5: ...AL GAS COMPANY OR GAS SUPPLIER FOR SERVICE DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE NEVER CHECK FOR LEAKS WITH A MATCH OR OPEN F...

Страница 6: ...period contact Omcan Inc at 1 800 465 0234 to schedule a drop off to either an Omcan authorized service depot in the area or to an Omcan Service warehouse to repair the equipment Unauthorized mainten...

Страница 7: ...lift the fryer at any time WARNING DO NOT OPERATE THIS OUTDOOR APPLIANCE UNDER OVERHEAD UNPROTECTED CONSTRUCTION THIS APPLIANCE SHALL BE USED ONLY IN A WELL VENTILATED SPACE AND SHALL NOT BE USED IN...

Страница 8: ...and hose assemblies supplied with this appliance must be used Replacement pressure regulators and or hose assemblies must be original manufacturers parts The standard self contained propane system fry...

Страница 9: ...er enclosed area Store only in a well ventilated area Do not store in the vicinity of any gas burning apparatus or in any high heat area such as a closed car or trunk Do not smoke while transporting a...

Страница 10: ...g all frying compound from the tank FILLING TANK WITH SHORTENING NOTICE Solid shortening should NOT be used with PRO FRYERS Melting solid shortening will damage the tank and void your warranty Close t...

Страница 11: ...YING INSTRUCTION WARNING Hot oil and parts can cause burns Use care when operating cleaning and servicing the fryer WARNING Spilling hot frying compound can cause severe burns Do not move the fryer wi...

Страница 12: ...ere burns Do not move the fryer without draining all frying compound from the tank 1 Turn the thermostat to OFF 2 Turn the gas valve to OFF 3 Let the shortening cool completely before draining 4 Direc...

Страница 13: ...s BOIL OUT PROCEDURE AS REQUIRED 1 Drain the tank as described under DRAINING THE TANK 2 Once the shortening has been drained flush out scraps and sediment with a small amount of warm shortening using...

Страница 14: ...on Pilot not lit Gas supply not turned on or connected Wire connections loose Thermopile Insufficient or too much heat Thermostat dial not set to desired temperature High limit tripped call service T...

Страница 15: ...15 Parts Breakdown Model CE CN OF LP 47354 Model CE CN DOF LP 47355...

Страница 16: ...9 Axle for 47354 12 AK427 Right Door for 47354 21 AK411 Thermopile for 47354 4 AK420 Caster Bracket for 47354 13 AK428 Door Lock for 47354 22 AK412 Burner for 47354 5 AK421 Caster for 47354 14 AK429 D...

Страница 17: ...19 Axle for 47355 12 AK427 Right Door for 47355 21 AK411 Thermopile for 47355 4 AK420 Caster Bracket for 47355 13 AK428 Door Lock for 47355 22 AK412 Burner for 47355 5 AK421 Caster for 47355 14 AK429...

Страница 18: ..._______________ ________________________________________________________________________________________ ________________________________________________________________________________________ ______...

Страница 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Страница 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Отзывы: