Maintenance
cause and service by yourself:
IF THE PRIMEAT® DOSEN’T START
•
Check that the power connection is correct.
• Check to see if the power supply is off.
•
Check whether a fuse has blown.
•
There may be a problem with the compressor: contact technical service.
IF THE COMPRESSOR OPERATES CONTINUOUSLY
• Check whether the door is opened frequently.
•
Check for open gaps in the door seal.
•
Check whether the goods are placed suitably.
• Check whether the air circulation is restricted from overfilling of shelves.
IF THE CABINET MAKES LOUD NOISES
• Check whether the cabinet is touching the wall or another piece of equipment or furniture.
IF THE PRIMEAT® COOLING SLOWLY
•
Check whether interior fan is starting or not.
• Primeat® may be filled over recomended capacity.
Warning: Your cabinet may not operate due to an opened thermal relay after a very short power failure.
For this reason please wait for the thermal relay to cool down and establish contact again by itself.
Содержание 47350
Страница 14: ...14 Figure Drawings ...
Страница 15: ...15 Figure Drawings ...
Страница 16: ...16 Electrical Schematics Model SLB080MEB 47350 ...