6
Operation
PANEL
The operation panel includes:
• 1 on/off button.
•
1 emergency stop button.
•
1 set button.
•
A 2 digit digital tube display.
•
A set of up and down arrow buttons to adjust the time.
The screen displays “--” in standby mode.
OPERATION
After the shaking machine is powered on, it enters the standby state. The shaking machine has 4 operating
states; standby, running, setting, emergency stop.
In the standby mode:
• Press the “on/off” button to enter the running mode.
•
Press the “set” button to enter the setting mode.
•
Press the arrow buttons to enter the direct view mode.
•
Press the emergency stop button to enter the emergency stop mode.
DEVICE OPERATION
Press the on/off button in the standby state, the device will start according to the currently set time parameters
and the digital tube will display the current operations countdown. When running, pressing the on/off button will
stop the running state and return the machine to the standby state.
TIME SETTING
Press the set button to enter the running time setting state. The digital tube displays the current setting value.
Press the arrow buttons to adjust the time and it will be displayed on the digital tube. By pressing the arrow
keys once, you can change the time values by 1 second. By holding the arrow buttons you can adjust the time
values quickly (between 1-99 seconds). Press the set button to save the current settings, press the set button
again to exit back to the standby state.
Note: If no action is taken for more than 5 seconds in the setting state, it will automatically return to the
standby state without saving.
EMERGENCY STOP FUNCTION
Once the emergency stop button is pressed, the device will enter the emergency stop state instantly. In this
state, the following happens:
1. The device stops running.
2.
The display screen flashes “PS”.
3.
After the emergency stop button is released, you can press the on/off button to return to the standby state.