Safety and Warranty

water before disconnecting the power.

5.  Release all pressure and drain all water from the system before servicing any component.

6.  Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing 

personal injury, and/or property damage.

7. 

Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life 

threatening safety hazard if the insulation becomes damaged or the connection ends fall into water. The 

use of an extension cord to power this pump is not permitted.

8.  Wear safety goggles at all times when working with pumps.

9. 

This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 

3-conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. 

The 3-prong plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type 

receptacle. Do not use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly 

grounded 3-prong receptacle (a GFCI outlet) installed in accordance with the National Electrical Code and 

local codes and ordinances. All wiring should be performed by a qualified electrician.

10. 

Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do 

not use damaged or worn cords.

11. 

Failure to comply with the instruction and designed operation of this unit may void the warranty. 

ATTEMPTING TO USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or 

death.

12. 

Ensure that the electrical circuit to the pump is protected by a 5-amp minimum (15-amp max.) fuse or 

circuit breaker.

13. Do not lift the pump by the power cord.

14. Know the pump and its applications, limitations, and potential hazards.

15. Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, 

sand, and debris. Disconnect the pump from the power supply before inspecting.

16. 

Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all 

Occupational Safety and Health Administration (OSHA) guidelines must be followed.

17. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will 

reset itself once the motor cools down and an acceptable temperature has been reached. The pump may 

start unexpectedly if it is plugged in.

18. 

Ensure the electrical power source is adequate for the requirements of the pump.

19. Before using the pump, check the hose for holes or excess wear, which could cause leaks, and ensure the 

hose is not kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of 

water quickly, and also check that all hose connections are tight to minimize leaks.

20. 

This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service 

for a long time when properly installed, maintained, and used. However, inadequate electrical power to 

the pump, dirt, or debris may cause the pump to fail. Please carefully read the manual and follow the 

instructions regarding common pump problems and remedies.

RESIDENTIAL USERS: Vendor assumes no liability for parts or labor coverage for component failure 

or other damages resulting from installation in non-commercial or residential applications. The right 

is reserved to deny shipment for residential usage; if this occurs, you will be notified as soon as 

possible.

1 YEAR PARTS AND LABOUR BENCH WARRANTY

Содержание 46788

Страница 1: ...Revised 07 05 2022 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Portable Hand Sink Item 46788 Instruction Manual ...

Страница 2: ...20 21 23 24 25 26 27 Table of Contents Section General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Notes Warranty Registration Item 46788 ...

Страница 3: ...utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication et distribution Companie Limité et Food Machinery d Amerique dba Omcan et Omcan Inc ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipemen...

Страница 4: ...ltos en la máquina Si el paquete ha sufrido un manejo de poco cuidado golpes o daños visible o oculto por favor anote en la factura antes de aceptar la entrega y contacte Omcan dentro de las 24 horas de modo que podamos iniciar una reclamación con la compañia Un informe detallado sobre los daños causados a la máquina debe ser llenado en el plazo de tres días desde la fecha de entrega que se muestr...

Страница 5: ...mp max fuse or circuit breaker 13 Do not lift the pump by the power cord 14 Know the pump and its applications limitations and potential hazards 15 Periodically inspect the pump and system components to ensure the pump suction screen is free of mud sand and debris Disconnect the pump from the power supply before inspecting 16 Follow all local electrical and safety codes along with the National Ele...

Страница 6: ...id the warranty Warranty covers electrical and part failures not improper use Please see https omcan com disclaimer for complete info WARNING The packaging components are classified as normal solid urban waste and can therefore be disposed of without difficulty In any case for suitable recycling we suggest disposing of the products separately differentiated waste according to the current norms DO ...

Страница 7: ...eel Electrical 120V 60Hz Weight 69 5 lbs 31 5 kgs Packaging Weight 75 lbs 34 kgs Fabricated Bowl Dimensions 12 x 14 x 6 305 x 356 x 152mm Dimensions 25 3 x 34 4 x 38 3 641 x 873 x 972mm Packaging Dimensions 26 8 x 35 4 x 48 8 679 x 899 x 1238mm The pump must be installed in a stationary position with either A fixed pipeline A flexible hose PLEASE NOTE 1 Do not allow the pump to hang suspended by t...

Страница 8: ...2 Position Pump on solid surface so that both hoses are free from kinks 3 Place unused end of intake hose in water to be transferred Place unused end of discharge hose as needed to direct the water discharge at least 3 feet away from the source INSTALLING THE WATER HEATER MOUNTING DRYWALL HOLLOW WALL 1 The selected wall or cabinet must be capable of supporting double the weight of the unit when co...

Страница 9: ...e valves Before changing the factory setting on the thermostat read the Temperature Regulation section in this manual This water heater shall not be connected to any heating systems or components used with a non potable water heating appliance Toxic chemicals such as those used for boiler treatment shall not be introduced into this system Water supply system may because of such events as high line...

Страница 10: ...of production of listed equipment of materials as meeting the requirements for Relief Valve for Hot Water Supply Systems ANSI Z21 22 CSA4 4 and the code requirements of ASME If replaced the valve must meet the requirements of local codes but not less than a combination temperature and pressure relief valve certified as indicated in the above paragraph The valve must be marked with a maximum set pr...

Страница 11: ...eset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperature pressure relief valve with a new one FILLING THE WATER HEATER Never use this water heater unless it is completely full of water To prevent damage to the tank and heating element the tank must be filled with water Water must flow from the hot wa...

Страница 12: ...ee wire 120 volt 60Hz grounded type outlet If an outlet is not within reach of the power cord contact a local electrician electrical contractor or the local electric utility to have a properly sized circuit including outlet wiring and breaker installed NOTE Check the water heater s data plate for power requirements If you are not familiar with the electric codes and practices or if you have any do...

Страница 13: ...ing size The larger the indentation the higher the temperature setting The temperature range of this water heater is 68 F at the lowest setting and 158 F at the maximum setting This water heater is shipped in the OFF position Adjust the dial to the desired temperature FOR YOUR INFORMATION THERMAL EXPANSION Water supply systems may because of such events as high line pressure frequent cut offs the ...

Страница 14: ...ted By doing so all warranty on the water heater tank is voided AIR IN HOT WATER FAUCETS HYDROGEN GAS Hydrogen gas can be produced in a hot water system that has not been used for a long period of time generally two weeks or more Hydrogen gas is extremely flammable and explosive To prevent the possibility of injury under these conditions we recommend the hot water faucet located farthest away be o...

Страница 15: ... to keep the tank in operating condition NOTE Artificially softened water is more corrosive because the process substitutes sodium ions for magnesium and calcium ions The use of a water softener may decrease the life of the water heater tank Anode deterioration depends on water conductivity not necessarily water condition A corroded or pitted anode rod indicates high water conductivity and should ...

Страница 16: ...SE the cold water inlet valve to the water heater 3 OPEN a nearby hot water faucet and leave open to allow for draining 4 Disconnect water connections Remove unit from wall UNIT WILL BE HEAVY Turn unit upside down and drain unit into a suitable drain or receptacle REMOVING THE FRONT PANEL 1 Turn off and unplug the water heater from the electric outlet and follow DRAINING INSTRUCTIONS 2 Remove the ...

Страница 17: ...ing plate affixed to the water heater 9 A new gasket must be used in all cases to prevent a possible water leak Place new element gasket in the element opening over the four element bolts orienting the gasket bulge facing waterside 10 Insert the curved part of the element rotate 20 clockwise and continue to insert the element being sure that the four bolts fit into the element flange 11 Replace th...

Страница 18: ...bout the operation of the water heater contact a service agency Use this guide to check a Leaking water heater Many suspected Leakers are not leaking tanks Often the source of the water can be found and corrected If you are not thoroughly familiar with your water heater and safety practices contact a qualified installer to check the water heater LEAKAGE CHECKPOINTS Read this manual first Make sure...

Страница 19: ...cord The pump does not prime The suction line is air leaked Repair suction line by tightening hose connection or replacing hose washer if necessary The impeller is clogged Remove the blockage The impeller is worn or damaged Replace the impeller The impeller is dry Add water to the pump inlet The flow rate is too low The hose is kinked or coiled Straighten the hose The strainer or hose is blocked C...

Страница 20: ... Flush Provide water treatment if needed Heater too small for job Install adequate heater Wrong piping connections Correct piping Leaking faucets Repair faucets Wasted hot water Review and reduce hot water consumption Long runs of exposed piping Insulate piping Hot water piping in exposed wall Insulate piping Slow hot water recovery Non functioning element Replace element Drip from relief valve Ex...

Страница 21: ...21 Parts Breakdown Item 46788 Pump ...

Страница 22: ...22 Parts Breakdown Item 46788 Electric Water Heater ...

Страница 23: ...788 3 AK250 Screw of Pump for 46788 6 AK253 Motor of Pump for 46788 9 Item No Description Position Item No Description Position Item No Description Position AK254 Fixed Plate of Water Heater for 46788 1 AK257 Decorative Cover of Water Heater for 46788 4 AK260 Rubber Sealing Ring of Water Heater for 46788 7 AK255 Heating Element of Water Heater for 46788 2 AK258 Knob of Water Heater for 46788 5 AK2...

Страница 24: ...24 Electrical Schematics Item 46788 ...

Страница 25: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Страница 26: ...________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ___________________________...

Страница 27: ...gister online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer from which Purchased Butcher Supermarket Catere...

Страница 28: ...s relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Amérique du Nord Europe Asie et Amérique du Sud nous travaillons continuellement à améliorer et développer l entreprise Nous nous efforçons d offrir à nos clients une valeur exceptionnelle grâce à nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 6500 produ...

Отзывы: