11
Troubleshooting
Compressor not working.
The voltage exceeds the allowed
fluctuation range.
Use voltage stabilizer and insert
proper power. Make sure the
equipment operates normally.
The output control loop of the
temperature controller disconnects.
Connect the loop.
Temperature controller is
damaged.
Repair or replace the temperature
controller.
Compressor is damaged.
Repair or replace the compressor.
Lamp not operating.
The power master switch is off or
the lamp switch is off.
Switch on.
Lamp’s connector contacts poorly. Reinsert the plugs after removing
and fixing them.
Lamp power transformer damaged. Replace power transformer.
The lamp is damaged.
Replace the tube.
Water leaks on floor.
Wicking pad is not absorbing
water.
Replace wicking pad.
Ambient room temperature
exceeds 75°F and 55% relative
humidity.
Connect appliance drain to floor
drain.
NON-FAULTS
1. When the compressor operates, the surface will be hot. In normal compressor operation, the surface
temperature will be high. This is normal. Do not touch with hands.
2. There is moisture condensation on the glass surface. With high environment temperature and humidity, it is
easy for dewdrop to appear on the external surface of the glass. Please wipe it using a soft dry cloth.
3. The room temperature is lower than the controlling temperature of the thermostat so that the compressor
breaks down. Because the room temperature is lower than the temperature of the thermostat, so the data
collected by the temperature sensor is not enough to start the compressor.