1 - MAINS SUPPLY CONNECTOR
2 - AC FUSE 1A
3 - FAN
4 - DB 9 PIN INPUT / OUTPUT CONNECTOR FOR TELEMETRY ( opt.01 )
5 - BNC FEMALE FOR CONNECTION OF THE INTERLOCK LOOP -
A CONNECTION TO GROUND INHIBIT RF POWER
6-7-8- BNC FEMALES FOR SUBCARRIERS GENERATORS INPUTS
9-10-11- SCA INPUT ADJUSTING LEVELS
12 - XLR FEMALE BALANCED MODE MONO AUDIO INPUT
13 - MONO INPUT ADJUSTING LEVEL
14 - BNC FEMALE FOR THE COMPOSITE MPX INPUT
15 - MPX INPUT ADJUSTING LEVEL
16 - N FEMALE FOR RF OUTPUT POWER
17 - EXTERNAL 15V DC POWER
18 - EXTERNAL 15V DC POWER FUSE
MAINS 110-220 VAC
AC
FUSE
RF OUTPUT
I/O
RS232
INTERLOCK
CE
2
17
18
5
16
4
1
SCA 3
SCA 2
SCA 1
MPX
MONO
50
75
S
1 GND
2
3
12
13
14
15
6
7
8
9
10
11
3