Components Illustration   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Eyepiece 

13 

USB Cable 

Diopter Adjusting Ring 

14 

Coarse Focus Knob 

Eyepiece Tube 

15 

Fine Focus Knob 

Nosepiece 

16 

X-Y Stage Moving Knobs 

Objective 

17 

Power Switch 

Slide Holder 

18 

Brightness Intensity Dial 

Mechanical Stage 

19 

Abbe Condenser 

Light Collector 

20 

Condenser Lock Thumb Screw 

Microscope Base 

21 

Condenser Control Knob 

10 

Viewing Head w Built-in Camera 

22 

Condenser Holder 

11 

Microscope Body 

23 

Color Filter Holder 

12 

Focusing Rack Stop Screw 

24 

Iris Diaphragm Lever 

 

10 

11 

12 

 

13 

14 

17 

15 

18 

16 

22 

 

 

23 

20 

19 

24 

21 

Содержание MD82ES10

Страница 1: ...User Manual Digital Compound Binocular LED Microscope Model MD82ES10 MicroscopeNet com...

Страница 2: ...tents i Caution 1 ii Care and Maintenance 2 1 Components Illustration 3 2 Installation 4 3 Operation 4 4 Specifications 8 5 Troubleshooting Guide 9 6 Darkfield Condenser Installation and Operation Ins...

Страница 3: ...ments Ensure the microscope is located on a smooth level and firm surface 4 If any specimen solutions or other liquids splash onto the stage objective or any other component disconnect the power cord...

Страница 4: ...ng an excessive amount of solvents as this may cause problems with optical coatings or cemented optics or the flowing solvent may pick up grease making cleaning more difficult Oil immersion objectives...

Страница 5: ...ve 17 Power Switch 6 Slide Holder 18 Brightness Intensity Dial 7 Mechanical Stage 19 Abbe Condenser 8 Light Collector 20 Condenser Lock Thumb Screw 9 Microscope Base 21 Condenser Control Knob 10 Viewi...

Страница 6: ...n 6 Dry Darkfield Condenser Installation Operation Instruction 3 Operation 3 1 Adjusting illumination 1 Plug the power cord into the power socket on the microscope and connect it to the power outlet 2...

Страница 7: ...same specimen into clear sharp focus by adjusting the diopter ring on left eyepiece tube only Do not use focus knobs at this step 5 Since both sides are adjustable you may also do the above in the op...

Страница 8: ...When you use the 100X objective to observe the specimen you have to apply the immersion oil on the top of the slide cover When you apply the immersion oil with the 100X objective do not let the immers...

Страница 9: ...back of viewing head and the other end to the computer 3 Turn on the computer install the camera following the manual in the mini CD 4 Open image observing software to examine more details see camera...

Страница 10: ...Condenser Abbe NA 1 25 w iris diaphragm and diffusion filter Rack and pinion adjustment Focus Mechanism Coaxial coarse and fine focusing knobs on both sides with rack stop Mechanical Stage Double laye...

Страница 11: ...get focused image No slide cover attached to the slide Attach a 0 17mm slide cover Slide cover is too thick or thin Use a slide cover of the appropriate thickness 0 17mm Slide may be upside down speci...

Страница 12: ...se the bolt to lock it when needed Note When raising the mechanical stage do not make contact with the objective 2 Centering the dry darkfield condenser Turn the 4X objective to the light path Turn th...