In  STBY,  if  WAIT-LED  is  on  or  the  amplifier  is  OFF,  the  amplifier                 

is  in  bypass-mode  and  your  transceiver  is  directly  connected  to  the     
antenna. Maximum allowed   power in bypass mode is 200 Watts! 

                          

 

RF OUTPUT  

Bar graph – shows output power . 

 

REFLECTED POWER 

          Bar graph –  shows reflected power from the antenna.  

 

 

 

 

    Maximum  level  is  350W  otherwise  amplifier  switches  to 

 

 

 

 

    STANDBY mode. 

 

Ig2

 

Bar  graph  –  measures  the  current  of  the  second  grid  from  -80mA  to 
+120mA. 

 

HV/IP/TUNE

           Bar graph – measure the anode voltage, anode currency or tuning of  PA. 

 
 

 

5.2.

 

Tuning of Power Amplifier 

 

The OM4000 HF amplifier is operated in class AB. Thus it’s possible to obtain a maximum 
output power at excellent linearity. For this purpose the amplifier has to be tuned carefully. 

 
 

WARNING! 

Before  starting  tuning  you  have  to  check  if  the  right  antenna  or  a  50  Ohms  load 
resistance is connected at the antenna output! 

 

CAUTION 

The  operation  of  a  mistuned  PA  will  cause  malfunctions,  the  increase  of  grid  current 
(the GRID-MAX-LED will light up) and problems with TVI/BCI.  

 

CAUTION 

The grid-current is shown with 2 LED diodes. It’s normal if the green LED is flashing or 
may  be  shining  a  little  bit  during  peak  operation.  If  you  overload  the  amplifier  the 
output  power  increases  the  grid  current  at  very  small  rates  and  the  red  GRID-MAX-
LED  is  shining  and  the  safety  devices  switch  the  PA  to  STBY.  You  must  decrease  the 
input power. 
 

CAUTION 

In  SSB  mode  you  will  have  good  output  power  if  the  green  LED  lights  up  a  bit.  The 
current of screen grid is  measured and shown in a Bar graph Indicator. The amplifier 
has  to  be  tuned  in  such  a  way  that  the  current  is  between  -  80  mA  to  +80  mA.    At 
currents beyond these values the operating point will be shifted and IM-products will be 
rapidly  increased.  If  a value  of  +  100mA  is  exceeded,  the  safety  devices  will  switch  the 
amplifier to STBY mode. 
 

 
 

 

Содержание OM4000HF

Страница 1: ...r s Manual External Radio Frequency Power Amplifier OM4000HF Model 4000HF Array Solutions 2611 North Beltline Rd Suite 109 Sunnyvale Texas 75182 USA Tel 214 954 7140 fax 214 954 7142 E mail info array...

Страница 2: ...5 3 GENERAL DESCRIPTION 6 3 1 HF part 6 3 2 Power Supply 7 3 3 Safety Devices 8 4 INSTALLATION 8 4 1 Grounding 8 4 2 Coaxial Cable 8 4 3 Control Cable 9 4 4 Mains Supply 10 4 5 Cooling 10 5 OPERATION...

Страница 3: ...Page 3 of 18 7 APPENDIX 17 7 1 Block Diagram of OM4000 HF Power Amplifier 17...

Страница 4: ...Automatic switching to STBY when reflected power is 350W or higher Intermodulation distortion 32dB below nominal output Suppression of harmonics 50 dBc Tubes 2x FU728F Ceramic tetrode Cooler Centrifu...

Страница 5: ...e Read next safety instructions carefully first before you will start to install and operate power amplifier NEVER VIOLATE NEXT RULES WARNING NEVER ALLOW CHILDREN to play around PA or to touch power a...

Страница 6: ...The amplifier is an A category product In a household it can influence other electric appliances In such cases the user is responsible to take proper actions to mitigate this disturbance CAUTION Read...

Страница 7: ...ft start is provided using relays and resistors The high anode voltage is made by combining 8 x 420 V total 3360V 2 5A Each has its own rectifier and filter In the high voltage circuit safety resistor...

Страница 8: ...has to be grounded properly Connect the screw on the rear panel of the amplifier to your local grounding system with a copper cable use a cross section of 4 mm2 at least Connect your transceiver to t...

Страница 9: ...tching Modern transceivers they have a time delay between PTT switching and power output CAUTION If you are using and older transceiver or transmitters without time delay we recommend to connect the P...

Страница 10: ...owed Do not obstruct air intake and exhaust areas of the PA The centrifugal blowers provide the necessary cooling of the amplifier even during long contests The main blower is activated by switching t...

Страница 11: ...plifier in the standby mode rather than switch it off 5 1 Operation Elements There is couple of operational elements accessible or visible on the front panel BAND Band selector switch not in the pictu...

Страница 12: ...50 Ohms load resistance is connected at the antenna output CAUTION The operation of a mistuned PA will cause malfunctions the increase of grid current the GRID MAX LED will light up and problems with...

Страница 13: ...ifier is ready for operation 4 Reduce the power output of your transceiver to the minimum 5 Switch OPR STBY to OPR position OPR LED lights up 6 Choose the TUNE position of multi meter 7 Transmit mode...

Страница 14: ...eed 100W otherwise PA will be damaged After this procedure the amplifier is tuned correctly and ready to give 1500W output power in all operation modes At optimal tuning and full output power a positi...

Страница 15: ...ter abt 2 sec the control circuits will switch the amplifier back to OPR CAUTION If the fault will repeat 3 times after each other the control circuits will turn the amplifier to STBY Bringing the amp...

Страница 16: ...m tube damaging contact the manufacturer or your dealer for ordering new one You will get instructuions how to change tube and how to preset proper parameters too Be very careful you will do it only o...

Страница 17: ...Page 17 of 18 7 APPENDIX 7 1 Block Diagram of OM4000 HF Power Amplifier...

Страница 18: ...Page 18 of 18...

Отзывы: