You can try to do this manually, too.
Scroll to
SET EBS1 MANUAL
and press
SET.
Use
up/down buttons to set 20mA or as close as
possible value and press
SAVE
.
Similar ways
EBS2
can be preprogrammed
( 300 mA FU-728F, 400mA GU84B and 500 mA
GU78B by AUTO set).
Or another value of EBS2 by MANUAL Set.
Scroll to
CALIBRATION Ip, Is
and press
SET
.
Calibration will be done automatically.
Scroll to
SWR PROTECT
and press
SET.
This feature allows user to switch OFF the SWR
This feature allows the user to switch
OFF
the
SWR protection.
We recommend setting it to
ON
(SWR protection circuit will stay active, max. allowed SWR is 3:1). If
OFF
is selected, higher SWR is allowed, but reflected power is measured. If it exceeds 350W, transmit will be
blocked.
Press EXIT.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.