OM POWER OM2500 A-F Скачать руководство пользователя страница 6

 

2.

 

SAFETY INSTRUCTIONS 

 
 

WARNING! 

DANGEROUS HIGH VOLTAGE! 

 

The  power  amplifier  is  using  high  voltage  up  to  close  3200V  DC,  which  is  very 
dangerous  for human  life!  Read  next  safety  instructions  carefully  first,  before  you will 
start to install and operate power amplifier!      NEVER VIOLATE NEXT RULES! 
 
WARNING!        NEVER  ALLOW  CHILDREN  to  play  around  PA  or  to  touch  power 
amplifier  or  connected  cables  in  working  condition,  or  to  push  anything  into  the  case 
holes! 
 
WARNING!  The amplifier contains  high voltage circuits. Never turn the amplifier on 
without the upper lid in place.  DO NOT ATTEMPT TO  SHORT  OR BYPASS safety 
switch under upper lid! 
 
WARNING!      The  OM2500A-F  amplifier  is  neither  to  be  used  in  a  WET  or  HUMID 
environment nor to be exposed to RAINFALL! 
 
WARNING!  Do not turn the amplifier on without having connected the ANTENNA or 
properly rated DUMMY LOAD! A hazardous HF voltage may build up on the antenna 
connector after turning the amplifier on with no antenna or dummy load connected! 
 
WARNING!  Before opening the upper lid of the amplifier make sure that power supply 
has  been  disconnected  AT  LEAST  10  minutes  allowing  the  electrolytic  capacitors  to 
discharge fully. Disconnect power cord from the outlet!  
 
CAUTION!  The amplifier must be installed in such a way that free flow of hot air from 
the  tube  is  allowed.  The  amplifier  must  not  be  installed  in  a constrained  surrounding 
(i.e. tight shelves etc.) 
 
CAUTION! The amplifier must be properly grounded during operation

 

CAUTION! During operation the amplifier must be installed in such a way that the rear 
power supplies are accessible. 
 
CAUTION!  The  amplifier  is  an  A category  product.  In  a household  it  can  influence 
other electric appliances. In such cases the user is to take proper actions to mitigate this 
disturbance. 
 
CAUTION!   Make sure that all screws holding the case together are properly  in place 
and tightened before  carrying the amplifier with the handles. 
 
CAUTION!  Read  this  manual  carefully.  Fallow  all  of  instructions  during  installation 
and  operation  to  avoid  damage  to  the  amplifier  not  covered  by  manufacturer´s 
warranty!  Do not attempt to perform any change of hardware or software!  
 
 

Содержание OM2500 A-F

Страница 1: ...Instruction Manual OM2500 A F SHORTWAVE POWER AMPLIFIER OM POWER s r o 930 30 B 126 SLOVAKIA E mail om power om power com...

Страница 2: ...Devices 8 4 INSTALLATION 8 4 1 Grounding 8 4 2 Coaxial Cable 9 4 3 I O Box and Interface 9 4 4 Main Supply 11 4 5 Cooling 12 4 6 Remote Control 12 5 OPERATION 12 5 1 Operation Elements 13 5 2 Configur...

Страница 3: ...24 7 APPENDIX 25 7 1 Example of connection for ICOM 25 7 2 Example of connection for ELECRAFT 26 7 3 Example of connection with YAESU 27 7 4 Example of connection with Antenna switch and BPF 28 7 5 Ex...

Страница 4: ...ds 1 8 29 7 MHz including WARC Power Output 1500w PEP continuous output all modes no time limit Input Power 40 to 60W for full output power Input Impedance 50 Ohm VSWR 1 2 1 Power Gain 15 dB Output im...

Страница 5: ...cators Power output 50 LED Reflected power 20 LED Current at screen Ig2 10 LED Anode voltage anode current tuning 30 LED LED Indicators Current at control grid Ig1 2 LED WAIT preheating of tube 180 se...

Страница 6: ...ad connected WARNING Before opening the upper lid of the amplifier make sure that power supply has been disconnected AT LEAST 10 minutes allowing the electrolytic capacitors to discharge fully Disconn...

Страница 7: ...t circuit with an input impedance of 50 Ohms This adaptable input circuitry ensures a good input SWR better than 1 5 1 on all amateur bands The output of the amplifier is a Pi L circuit The ceramic ca...

Страница 8: ...ssis subpanel 4 INSTALLATION NOTE Read this chapter carefully prior you will start installation Before unpacking inspect shipping woody container first if it is not damaged Keep all of packing parts f...

Страница 9: ...is shielded On the side of the power amplifier a CINCH socket is used On the side of your transceiver you have to use a socket suitable for this transceiver During transmitting the middle pin is conne...

Страница 10: ...ion ALC RCA Phono Automatic Level Control is used when tuning the PA to block drive level BYPASS COM Connector 5 5 2 1mm allows you to connect an external 12V DC power supply rated at 200mA max which...

Страница 11: ...a port 4 5 antenna port 5 6 antenna port 6 7 antenna port 7 8 antenna port 8 9 antenna port 9 10 antenna port 10 11 COMMON port of ANT SW 12 NC 13 GND 14 BPF 160m 15 BPF 80m 16 BPF 40m 17 BPF 30m 18 B...

Страница 12: ...supplemental fan is turned on depending on the temperature of the air exiting from the amplifier It is switched on at 70 C and switched off at 60 C 4 6 Remote Control Control of the amplifier is poss...

Страница 13: ...arm up delay the amplifier will be ready for operation OPR STBY OPERATE sets the amplifier ready for transmit operation In STBY if WAIT LED is on or the amplifier is OFF the amplifier is in bypass mod...

Страница 14: ...enna on a given frequency SET button for MAIN MENU Confirmation of selection Saving of selected value Saving of tuning parameters TUNE Push button for selection of TUNE mode AUTO Push button for selec...

Страница 15: ...tinue by selecting Baud Rate Press SET button and scroll using UP DWN to BAUD RATE Press SET again By scrolling UP DWN select desired Baud Rate which must be the same as baud rate used by your transce...

Страница 16: ...s of Kenwood an external IF 232 converter is to be used You can also use devices from several companies that produce compatible CI V output which deliver frequency information in ICOM format through t...

Страница 17: ...u want per current band 1 or 2 and always confirm your selection by pressing SET The by scrolling UP DWN you assign which PORT is used on your external antennas switch for this particular antennas ANT...

Страница 18: ...P DWN to select which option and confirm by SET 5 2 7 MUTE option When operating the OM2500A F with an Icom transceiver without TX INHIBIT for disabling TX we recommend blocking of the TX while tuning...

Страница 19: ...and pressing Up or DWN you can vary the Contrast of the LCD display Press SET for confirm the setting 5 2 9 Operation in MANUAL mode To enter Manual mode of the PA please press MAN By pressing MAN rep...

Страница 20: ...Bar graph Indicator The amplifier has to be tuned in such a way that the current is between 20 mA to 50 mA At currents beyond these values the operating point will be shifted and IM products will be r...

Страница 21: ...3 to get maximum output power Second if your antenna parameters are not very good and input power is higher than 15watts safety devices will switch PA automatically to STBY In such a case start with s...

Страница 22: ...nput power is LOW After excluding possible human mistakes you will be able to work for long time with this amplifier 5 3 3 Tuning Adjustment Entering the TUNE mode is done by pressing the TUNE button...

Страница 23: ...amplifier back to OPR CAUTION If the fault will repeat 3 times after each other the control circuits will turn the amplifier to STBY Bringing the amplifier to OPR is enabled by using the OPR STBY swi...

Страница 24: ...u will get instructuions how to change tube and how to preset proper parameters too Be very careful you will do it only on your own risk If you are not comfortable to replace vacuum tube itself contac...

Страница 25: ...25 7 APPENDIX 7 1 Example of connection for Icom...

Страница 26: ...26 7 2 Example of connection for ELECRAFT...

Страница 27: ...27 7 3 Example of connection with Yeasu...

Страница 28: ...28 7 4 Example of connection with antenna switch and BPF...

Страница 29: ...29 7 5 Example of connection USB micro KEYER II with IC7800 or IC7700...

Страница 30: ...30 7 6 Example of connection USB micro KEYER II with another Icom...

Страница 31: ...31 7 7 Example for connection USB micro KEYER II with Yeasu or ELECRAFT...

Страница 32: ...32 7 8 Example of connection PA with MicroHAM MKII MK2R etc with CI V output...

Страница 33: ...33 9 1 Block Diagram of OM2500A F Power Amplifier USA version...