OLYS MPPT5012A-DUO-BT Скачать руководство пользователя страница 3

1 .)  

Main Battery  “MAIN I”

 (

must be connected):

Connect the 

battery connections

 of the controller - (Minus) and + (Plus) to the 12 V main battery, observing the correct

polarity and the cross section of the cables (refer to connection plan).

Never operate the controller without the battery “Main I” . If the battery is not connected, the unit will not deliver a

defined output voltage.

In case of wrong polarity of battery I, the internal safety fuse will be released.The replacement fuse should have the same

capacity, and it should be of the same type (car fuse)!

Parallel charging

 of two or several batteries of the same voltage (12 V) is admissible. The batteries are to be “paralleled”

2 . )  

Solar Panel (must be connected):

         Shade the panels to minimize sparking during connection and to avoid damages due to eventual wrong polarity.

         Observe the cable cross-sections (refer to connection plan)!

         If several small solar panels are used, they are connected in parallel (refer to connection plan). Partial shading of the panels

         results in average higher capacity (see connection plan).

3 .) 

Starter Battery „START II“ (Option, can be connected):

        Connect the second charging port to the second battery using the red connection cable (wire cross section 1.5 - 2.5 mm²).

        This cable may be longer. In case of non-utilization, this terminal is left free.

        If used, the output for starter battery II will be working with reduced voltage and charging current rates. Thus, the valuable

        solar power will be supplied to board/solar battery I being more suitable.

        However, the vehicles starter battery II will be kept in a condition, that starting will always be possible, even in case of

        longer downtimes and during winter operation.

        Connection of the negative pole „START II“ is not required, if the negative pole „BOARD I“ is connected to the

        vehicle body. Depending on the length of the cable, it may also be connected to the common negative

        connection of the solar controller or to the negative pole of „BOARD I“.

4.)  

Temperature Sensor (Option, can be connected):

For automatic adaptation and correction of the charging voltage to the battery temperature (temperature compensation).

Mounting:

The thermal contact of sensor and battery "Main I" (inside temperature) should be well. Thus, it should be screwed down

to the negative pole or positive pole of the battery. It is also possible to fasten it at the sidewall centre of the battery casing.

Ensure that the installation place is not influenced by any source of heat (motor block, exhaust, heater etc.).

Connection:

Connect the temperature sensor to the terminal by means of a 2-pole cable (cable cross section 0.5 - 1.5 mm²). The polarity

and cable length is of no importance. The solar controller recognizes the sensor automatically.

Effect:

The temperature-dependent charging voltage of battery I will be adapted automatically to the battery temperature.

The temperature sensor measures the battery temperature. In case of low temperatures (winter operation), the charging

voltage will be increased in order to improve and accelerate full charging of the weak battery.

Safety Mode:

The solar controller recognizes automatically a missing sensor, cable break or short-circuit of the sensor lines, as

well as unreasonable measuring values. In that case, it will switch automatically to the usual charging voltage

rates of 20 °C / 25 °C being recommended by the battery manufacturers.

5)

The LCD display indicates the following values: Battery voltage, charging current, charging
capacity, stored capacity and energy (V, A, W, Ah, Wh)

5) 

LCD

 

meter

 (

Option, can be connected):

Содержание MPPT5012A-DUO-BT

Страница 1: ...s is highly recommended if the battery is exposed to strong variations in temperature such as in the motor compartment Increased MPP charging current compared with conventional controllers due to ultramodern controller technology User Manual MPPT5012A DUO BT MPPT5025A DUO BT Thank you very much for buying our product Please read thoroughly before using the prouuct solar controller Dual battery MPP...

Страница 2: ...assignment consists of the solar panel inputs and and the connections of the main battery Always connect the fuses as close as possible to the batteries cable protection Required Cable Cross Sections MPPT5012A DUO MPPT5025A DUO Panel cables length as required 2 5 4 mm 2 6 10 mm 2 Battery I cables length max 2 m 2 5 4 mm 2 6 10 mm 2 Fuse close to battery I 20 A 40 A Notes Connection The polarities ...

Страница 3: ... operation Connection of the negative pole START II is not required if the negative pole BOARD I is connected to the vehicle body Depending on the length of the cable it may also be connected to the common negative connection of the solar controller or to the negative pole of BOARD I 4 Temperature Sensor Option can be connected For automatic adaptation and correction of the charging voltage to the...

Страница 4: ... voltage or PV over voltage MPP If it is lighting Proper functioning of the solar controller Short flashing Display of readiness for service in case of missing solar power at night Batt Low yellow If it is lighting Low voltage at main battery I voltage 10 5V The battery should be recharged as soon as possible All pilot lamps 5 are flashing The positions of the selector switches MAIN Battery are in...

Страница 5: ...e Measurement Measurement of the voltage is to be effected at the battery and never at the solar controller loss at the charging cable Overvoltage Protection Battery charging parameter Battery type GEL Lead Aicd AGM1 AGM2 LiFePO4 Boost charging voltage 14 3V 3 10h 14 4V 1 5 6h 14 7V 1 5 5h 14 6V 0 5 3h Float charging voltage 13 8V 13 45V 13 5V 13 6V Default temperature 20 20 20 20 ATTENTION Only c...

Страница 6: ... Device Yes Yes Integrated Protection against Short circuit Yes Yes Integrated Protection against Overtemperature Yes Yes Integrated Cooling Fan with Temp Control Yes Yes Unit Fuse Type FKS 30A 40 A Input for Battery I Temperature Sensor Yes Yes Charging Timer 3 fold 3 fold Auxiliary Port Vehicle Starter Battery II Start II Charging Current 0 1 0 A 0 1 0 A Overload Protection Current Limiting Devi...

Страница 7: ...ou can see the parameter after 3 5second from APP 7 The distance between phone and bluetooth is 10 meters if no signal reconnect the device IOS automatically run no need search device 3 Run the bluetooth function of the mobile phone charging SHENZHEN OLYS COMPANY LIMITED Addr 5 floor B building of Sheng De Industrial Park Lang Kou Da Lang Long Hua New district Shenzhen Guangdong China TEL 86 0755 ...

Отзывы: