OLYS MPPT5012A-DUO-BT Скачать руководство пользователя страница 1

Description

 

of

 

Functions

1. 

     (microprocessor) by 10 % to 30 % (efficiency > 95 %)

2. 

Switchable characteristic lines of charging

 for optimum charging of Gel/dryfit/AGM/fleece or acid/lead-acid, as well

    as LiFePO4 batteries .

3. 

Two Battery Charging Ports

: Automatic charging of the main battery or board battery (Board I):

    Support charging and trickle charging (max. 1 A) of the vehicle's starter battery (Start II) with overcharge protection

4. 

Unattended Charging

: Standard protection against overload, overheating, reverse battery and back discharge of the

    battery (in case of insufficient solar power, such as at twilight, at night etc.).

5. 

Overcharge protection

: Reduction of the charging current of the battery in case of excessive solar power and full

    battery. Immediate recharging in case of power consumption to ensure always the best possible charging state of the

battery.

6. 

Connection for temperature senso

r

,

Automatic adaptation of the charging voltage to the battery temperature. In case 

    of low outside temperatures, full

    charging of the weaker battery is improved, and in case of summery temperatures unnecessary battery gassing will

    be avoided.

   

This is highly recommended, if the battery is exposed to strong variations in temperature, such as in the motor

    compartment.

 

  

Increased MPP charging

 current compared with conventional controllers, due to ultramodern controller technology

User Manual

MPPT5012A-DUO-BT

MPPT5025A-DUO-BT

Thank you very much for buying our product ,Please read

thoroughly before using the prouuct

solar controller

Dual battery 

MPPT

Safety Regulations and Appropriate Application:

1.Charging of lead-gel, lead-AGM, lead-acid or LiFePO4 (with integrated BMS!) batteries of the indicated nominal voltage 

  and simultaneous supply of the consumers being connected to these batteries in fixed installed systems.

2.Solar panels up to the maximum power rating (Wp) of the used solar controller.

3.

The indicated cable cross sections at the charging ports and at the panel input.

4.

With fuses of the indicated capacity near the battery to protect the cabling between battery and charging ports.

5.

Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gas, as well as in an 

   environment being free from condensation water

6.Except for the fuse, the unit is not equipped with parts, which can be replaced by the user. Always use replacement car 

  fuses of the indicated capacity!

7.Keep children away from the solar controller and the batteries.

Содержание MPPT5012A-DUO-BT

Страница 1: ...s is highly recommended if the battery is exposed to strong variations in temperature such as in the motor compartment Increased MPP charging current compared with conventional controllers due to ultramodern controller technology User Manual MPPT5012A DUO BT MPPT5025A DUO BT Thank you very much for buying our product Please read thoroughly before using the prouuct solar controller Dual battery MPP...

Страница 2: ...assignment consists of the solar panel inputs and and the connections of the main battery Always connect the fuses as close as possible to the batteries cable protection Required Cable Cross Sections MPPT5012A DUO MPPT5025A DUO Panel cables length as required 2 5 4 mm 2 6 10 mm 2 Battery I cables length max 2 m 2 5 4 mm 2 6 10 mm 2 Fuse close to battery I 20 A 40 A Notes Connection The polarities ...

Страница 3: ... operation Connection of the negative pole START II is not required if the negative pole BOARD I is connected to the vehicle body Depending on the length of the cable it may also be connected to the common negative connection of the solar controller or to the negative pole of BOARD I 4 Temperature Sensor Option can be connected For automatic adaptation and correction of the charging voltage to the...

Страница 4: ... voltage or PV over voltage MPP If it is lighting Proper functioning of the solar controller Short flashing Display of readiness for service in case of missing solar power at night Batt Low yellow If it is lighting Low voltage at main battery I voltage 10 5V The battery should be recharged as soon as possible All pilot lamps 5 are flashing The positions of the selector switches MAIN Battery are in...

Страница 5: ...e Measurement Measurement of the voltage is to be effected at the battery and never at the solar controller loss at the charging cable Overvoltage Protection Battery charging parameter Battery type GEL Lead Aicd AGM1 AGM2 LiFePO4 Boost charging voltage 14 3V 3 10h 14 4V 1 5 6h 14 7V 1 5 5h 14 6V 0 5 3h Float charging voltage 13 8V 13 45V 13 5V 13 6V Default temperature 20 20 20 20 ATTENTION Only c...

Страница 6: ... Device Yes Yes Integrated Protection against Short circuit Yes Yes Integrated Protection against Overtemperature Yes Yes Integrated Cooling Fan with Temp Control Yes Yes Unit Fuse Type FKS 30A 40 A Input for Battery I Temperature Sensor Yes Yes Charging Timer 3 fold 3 fold Auxiliary Port Vehicle Starter Battery II Start II Charging Current 0 1 0 A 0 1 0 A Overload Protection Current Limiting Devi...

Страница 7: ...ou can see the parameter after 3 5second from APP 7 The distance between phone and bluetooth is 10 meters if no signal reconnect the device IOS automatically run no need search device 3 Run the bluetooth function of the mobile phone charging SHENZHEN OLYS COMPANY LIMITED Addr 5 floor B building of Sheng De Industrial Park Lang Kou Da Lang Long Hua New district Shenzhen Guangdong China TEL 86 0755 ...

Отзывы: