OLYS MPPT15060 Скачать руководство пользователя страница 2

Part

 

name

1

2

3

4

5

6

7

8

9

10 1

1

1

2

1

3

1

2

3

4

5

6

7

8

9

10

11

12

13

LCD

Φ5 

Mounting hole

Load

 

status

red

Chrge

 

status

green

Input PV1

Battery terminal

Dry contact terminal

RS485 Communication

Attention

!

Input solar panel matrix power 

Grounding operation.

Input PV2

Forward or Increase

Backward

 

or

 

Reduce

Setting or Enter

Load ON/OFF or Ese

1. the MPPT solar controller has the function of simultaneous input of two solar panels. In theory, the two solar panels can input

 different open circuit voltages and different power, and both can work normally. however, in order to balance the overcurrent 

 inside the controller, it is strongly recommended that the solar panels of the same specification be used in both ways, which is 

 beneficial to the service life and efficiency of the controller. 

2.

The controller has a limited power function, and when the total power of the two solar panels or each input solar panel exceeds

   the rated power, the controller will limit the charging power to the rated power, so it is strongly recommended not to connect to 

  solar panels that exceed the rated power.

Connect the wire

1.For the specification of the connecting cable, refer to the installation instructions. 

2.When the connection cable between the solar panel or controller and the battery is relatively far away, the use of a thicker cable 

can reduce the voltage drop and increase charging efficiency

Installation and connection

Warning: the danger of explosion! 

Never install the controller and thebattery in the same airtight space! Nor should it be installed in an airtight battery where gas 

may accumulate the place. 

Warning: high pressure is dangerous! 

PV  arrays may generate high open-circuit voltages. Disconnect circuit breakers or safety before wiring, and be careful 

during wiring. 

Note

: when installing the controller, make sure that enough air flows through the heat sink of the controller, and there is at least 

150mm space above and below the controller to ensure natural convection and heat dissipation. 

If installed. In a closed box, it is necessary to ensure reliable heat dissipation through the box.

MPPT15060 is a common positive design controller. The 

 electrode of solar panel and battery can be grounded at the 

same time, or any 

 terminal can be grounded. In practical application, the terminal can also be grounded. 

It is not necessary to ground separately, but the shell must be grounded during installation, which can prevent external 
electromagnetic interference and shell electrification from causing damage to the human body.

positive

positive

Temperature compensation

Note

: when the remote temperature sensor is not connected, the controller will charge or discharge the battery at 25 

 by 

default, without temperature compensation.

Modification of battery charging parameters

Note: when selecting the default battery type, the charging parameters cannot be modified. If you want to modify the charging 
parameters, the battery type must select "Custom".

Overheat protection

When the internal temperature of the controller is more than 80 

, the controller stops working. When the temperature drops 

to 60 

, the controller resumes charging. If the overtemperature protection is repeated three times, the charge will be stopped

completely. which needs to be reset manually or can be recharged the next day.

14

14

Temperature sensor

Содержание MPPT15060

Страница 1: ...sure that the battery works in the best state and greatly prolong the service life of the battery 8 It has full automatic control such as overcharge overdischarge overload protection anti reverse protection and so on The charge regulator is intended for use in photovoltaic systems with 12V or 24V nominal voltages It shall be used with vented or sealed VRLA lead acid batteries only Safety Recommend...

Страница 2: ...irtight battery where gas may accumulate the place Warning high pressure is dangerous PV arrays may generate high open circuit voltages Disconnect circuit breakers or safety before wiring and be careful during wiring Note when installing the controller make sure that enough air flows through the heat sink of the controller and there is at least 150mm space above and below the controller to ensure ...

Страница 3: ...afety accidents Connection cable the connection cable between the controller and the battery is as short as possible which can effectively reduce the cable loss and reduce the voltage difference Recommended cable specifications length 4m 8mm length 4m 10mm2 1 The controller has two solar panel input ports each with a maximum charging current of 30A It can be connected arbitrarily and the controlle...

Страница 4: ...ntal stripes rolling up dynamically Load ON Load OFF Press K1 or K2 to cycle forward or backward to browse the current working parameters or set working status Battery voltage PV1 voltage PV2 voltage Charge current PV power Ambient temperature Charging capacity AH Charging capacity WH Parameter setting browsing In the battery voltage display interface press the K3 button for 5 seconds to enter the...

Страница 5: ...erface Browse and press K1 or K2 to cycle to the parameter interface you want to set Short press K3 button SET display SET font flashes to indicate that you can start to change the current parameter press K1 or K2 to modify the parameter value and then press K3 button set button save the current settings and the word SET will stop flashing and so on you can set other parameters Press K4 key to dir...

Страница 6: ...ashes press K1 or K2 key to change the number of minutes in a cycle 0 59 5 Press the K3 key again the SET and M icons stop flashing the load time is set and save the settings Dual period real time control mode Turn the page of the load working mode to the dual period real time control interface mode 5 1 Press the K3 key the H icon flashes the ON1 icon is on press K1 or K2 key to modify the cycle n...

Страница 7: ... the battery voltage here otherwise The controller will report an error and the controller will not work Battery voltage Automatic identification Set night detection voltage The night detection voltage is the voltage of the solar panel when the load is turned on and output it needs to be used when the load working mode is set to pure light control or light control time control Charging capacity se...

Страница 8: ...ror code is displayed and the buzzer alarms synchronously and the alarm continues until the error is corrected Press K4 to exit the wrong generation interface return to the main interface and turn off the buzzer Start timing If the error persists after 10s the alarm will continue Ring every 0 5 seconds for one minute rings once in 0 5 seconds and the full battery icon flashes rings once in 0 5 sec...

Страница 9: ... Float charge 13 5V 13 8V 13 5V 13 14V Boost charge recovery 13 2V Low voltage recovery load output 12 5V 11 5V 12 5V Low voltage protection shut off load 11V 10 5V 11 5V Equalization charge time 120min Temperature compensation 3mv 2V Load work mode manual light control time contorl Real time timing control Night detection voltage 6V Dry contact terminal output voltage Same as battery voltage curr...

Отзывы: