AES Function
Activate AES condition:
•
After 5 minutes of constant voltage charging
Conditions for closing AES:
1. Within the following voltage range, AES must be turned on for 30 minutes before it can be turned off.
2. When the battery voltage is too low, turn off AES after 5 seconds
Battery type
Lead-acid,GEL,AGM
12.3V<=Voltage<13V
Voltage range
LiFePO4
13.1V<=Voltage<13.5V
Li
-
ion
(
NCM
)
11.9V<=Voltage<12.1V
After working for 30 minutes,
turn off AES
Battery type
Lead-acid,GEL,AGM
<12.3V
Voltage range
LiFePO4
<13.1V
Li
-
ion
(
NCM
)
<11.9V
turn off AES after 5 seconds
Start battery charge control
Start battery charge conditions
1. The charger is in the constant voltage charge or float charge stage
2. Start battery voltage 6-12.8V
3. The start battery voltage is less than or equal to 0.3V of the main battery
The above 3 items last for 10 seconds
Start battery stop charge conditions
1. The charger is in the Boost charge or stop charge
2. The start battery voltage is greater than the main battery voltage minus 0.3V or more
3. Start battery voltage>14.3V
Stop charge if any of the above conditions are met
If the charging is turned off, it is only allowed to recharge after 5 minutes or if the starting
battery voltage is less than 11.8V, the charging should be resumed immediately