OLYS MPPT10050 Скачать руководство пользователя страница 1

Description

 

of

 

Functions

1. 

     (microprocessor) by 10 % to 30 % (efficiency > 95 %)

2. 

Switchable characteristic lines of charging

 for optimum charging of Gel/dryfit/AGM/fleece or acid/lead-acid, as well

    as LiFePO4 batteries .

3. 

Two Battery Charging Ports

: Automatic charging of the main battery or board battery (Board I):

    Support charging and trickle charging (max. 2.5 A) of the vehicle's starter battery (Start II) with overcharge protection

4. 

Unattended Charging

: Standard protection against overload, overheating, reverse battery and back discharge of the

    battery (in case of insufficient solar power, such as at twilight, at night etc.).

5. 

Overcharge protection

: Reduction of the charging current of the battery in case of excessive solar power and full

    battery. Immediate recharging in case of power consumption to ensure always the best possible charging state of the

battery.

6. 

Connection for temperature senso

r

,

Automatic adaptation of the charging voltage to the battery temperature. In case 

    of low outside temperatures, full

    charging of the weaker battery is improved, and in case of summery temperatures unnecessary battery gassing will

    be avoided.

   

This is highly recommended, if the battery is exposed to strong variations in temperature, such as in the motor

    compartment.

 

  

Increased MPP charging

 current compared with conventional controllers, due to ultramodern controller technology

User Manual

MPPT10060 | MPPT10060-DUO

Thank you very much for buying our product ,Please read

thoroughly before using the prouuct

solar controller

Dual battery 

MPPT

Safety Regulations and Appropriate Application:

1.Charging of lead-gel, lead-AGM, lead-acid or LiFePO4 (with integrated BMS!) batteries of the indicated nominal voltage 

  and simultaneous supply of the consumers being connected to these batteries in fixed installed systems.

2.Solar panels up to the maximum power rating (Wp) of the used solar controller.

3.

The indicated cable cross sections at the charging ports and at the panel input.

4.

With fuses of the indicated capacity near the battery to protect the cabling between battery and charging ports.

5.

Installation in a well-ventilated room, protected from rain, humidity, dust, aggressive battery gas, as well as in an 

   environment being free from condensation water

6.Except for the fuse, the unit is not equipped with parts, which can be replaced by the user. Always use replacement car 

  fuses of the indicated capacity!

7.Keep children away from the solar controller and the batteries.

MPPT10050 | MPPT10050-DUO

Содержание MPPT10050

Страница 1: ...ghly recommended if the battery is exposed to strong variations in temperature such as in the motor compartment Increased MPP charging current compared with conventional controllers due to ultramodern...

Страница 2: ...els should be protected from direct sunlight by covering or shading prior to connection met er optional BOA RD option Bluetooth Dongle START AES Bord Full Charge AES Solar Display Battery type Bluetoo...

Страница 3: ...t the temperature sensor to the terminal by means of a 2 pole cable cable cross section 0 5 1 5 mm The polarity and cable length is of no importance The solar controller recognizes the sensor automati...

Страница 4: ...Lithium ion NCM ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON OFF Warning 14 4V 14 7V 14 4V 12 6V 13 9V 14 2V 14 6V 2 It is not allowed to change the battery type during the charging process If nece...

Страница 5: ...hort flashing Voltage is normal 1time 5 s Fast flashing Over voltage HVD 1time 1 s ON Low voltage LVD Battery full Off No charging Short flashing Boost charging stage 1time 5S Fast flashing Constant v...

Страница 6: ...AES after 5 seconds Start battery charge control Start battery charge conditions 1 The charger is in the constant voltage charge or float charge stage 2 Start battery voltage 6 12 8V 3 The start batt...

Страница 7: ...V 60A 0 2 5A 3mv 2V LiFePO4 Nominal Voltage lithium ion NCM Nominal Voltage Capacity Battery Size recommended Lead Acid Gel AGM Batteries Nominal Voltage Vehicle Starter Battery Start II Vehicle Start...

Отзывы: