![OLYS B2B122425 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/olys/b2b122425/b2b122425_mounting-instruction-and-operating-manual_735842008.webp)
Code
Name
Color
Stats
L5
Solar
Green
OFF: B2B mode
Short flashing: PV voltage <Board battery voltage
(1time / 5s)
Fast flashing: PV voltage >50V (1 time/ 2 s)
ON: PV voltage is normal
B
O
A
R
D
Ⅰ
L1
L2
L3
L4
ON
1
2
3
4
S
o
la
r
Charging process
V/I
(V)
Float
voltage
Boost voltage
<100%
<75%
100%
充 满
Voltage curve
充电 时间
B
a
tt
e
ry
fu
ll
C
h
a
rg
e
S
ta
rt
Ⅱ
L
5
1. Boost charge stage: Charge according to the maximum current until the battery voltage
reaches the boost voltage. Boost voltage refer to charging parameters.
2. Constant voltage charge stage: When the battery voltage rises to the boost voltage,
the charging current begins to drop, constant voltage charging time is 2hours.
■
When the battery is first charged, the voltage >12.6V, Charge without constant voltage
for 2 hours, directly float charge
3. Float charge stage : Low current to maintain float voltage
Current curve
Boost Charge
Constant voltage charge
Float Charge