Olympus U-RFL-T Скачать руководство пользователя страница 1

INSTRUCTIONS

U-RFL-T

POWER SUPPLY UNIT

This instruction manual only covers the power supply that is for the Olympus Power Supply Unit
U-RFL-T. To obtain optimum performance and to familiarize yourself fully with the use of this
power supply unit, we recommend that you also study the instruction manual for the microscope
to be used. Retain this instruction manual in an easily accessible place near the work desk for
future reference.

        This publication is printed on 100% recycled paper

A X 7 1 1 4

Содержание U-RFL-T

Страница 1: ...tain optimum performance and to familiarize yourself fully with the use of this power supply unit we recommend that you also study the instruction manual for the microscope to be used Retain this inst...

Страница 2: ......

Страница 3: ...y sometimes rupture 4 When disposing of the mercury burner always follow national and local laws and guidelines 5 The power supply unit contains high voltage components Never attempt to modify or disa...

Страница 4: ...the equipment Indicates that failure to follow the instructions could result in damage to equipment Indicates commentary for ease of operation and maintenance 1 Getting Ready 1 A power supply unit is...

Страница 5: ...gram 1 2 2 Mounting the Mercury Burner 2 2 3 Cable and Cord Connections 3 3 PREPARATION FOR OBSERVATION 4 3 1 Igniting the Mercury Burner 4 3 2 Centering the Mercury Burner 4 4 SPECIFICATIONS 5 5 TROU...

Страница 6: ...sembly Diagram Lamp housing U ULH Mercury burner configuration Mercury burner USH102D HBO103W 2 Socket U ULS100HG Power Supply Unit U RFL T To illuminator of microscope frame AX BX BX2 IX etc Collecto...

Страница 7: ...using the lamp housing U ULH Fig 3 Fig 4 When using the 100W lamp housing U LH100HG LH100HGAPO 1 Loosen the burner socket clamping screw using the Allen screwdriver Fig 3 2 While holding the upper par...

Страница 8: ...erminal of the power supply unit and that of the wall outlet are properly connected If the equipment is not grounded Olympus can no longer warrant the electrical safety and performance of the equipmen...

Страница 9: ...ATION Fig 9 After turning the burner off it cannot be re ignited before the mercury vapor cools and condenses to a liquid Wait for at least 3 minutes before restarting the burner Opening the lamp hous...

Страница 10: ...87 in H 5 Weight 4 8 kg 10 6 lb Operating Environment Indoor use Altitude Max 2000 m Ambient temperature 5 to 40 C 41 to 104 F Maximum relative humidity 80 for temperatures up to 31 C 88 F decreasing...

Страница 11: ...O OFF Turn to I ON again Repeat as necessary c The burner flickers or is dark Insufficient time has elapsed since Wait for 10 minutes after turning on the the burner was turned on burner The burner l...

Страница 12: ...Table 1 Certified Cord A power supply cord should be certified by one of the agencies listed in Table 1 or comprised of cordage marked with an agency marking per Table 1 or marked per Table 2 The fit...

Страница 13: ...rds Authority of Ireland NSAI Norges Elektriske Materiellkontroll NEMKO Asociacion Electrotecnica Y Electronica Espanola AEE Hellenic Organization for Standardization ELOT Instituto Portages da Qualid...

Страница 14: ...MEMO...

Страница 15: ......

Страница 16: ...rate Center Drive Melville NY 11747 3157 U S A 491B River Valley Road 12 01 04 Valley Point O ce Tower Singapore 248373 2 8 Honduras Street London EC1Y OTX United Kingdom 31 Gilby Road Mt Waverley VIC...

Отзывы: