  Attaching the U-HSEXP (Fig. 3)

} The U-HSEXP is composed of the U-HSEXP switch (fixed by magnet) and 

circular iron plates (adhesive). Two circular plates are provided, with one of 
them intended for use as the spare.

1. Attach the switch 

@

 on the center of the circular plate 

2

 by means of 

magnet.

  Do not remove the backing sheet of the circular plate until the final fixing 

position is decided.

2. Decide the final fixing position that is most convenient for controlling the 

switch from the area 

3

 (indicated by 

 in the figure) near the coarse 

adjustment knob on the left or right. 

3. Clean the final fixing position with absolute alcohol, remove the backing 

sheet from the round plate and apply it securely on the final fixing positi-
on.

  If there is an article with magnetic field near the U-HSEXP, equip-

ment  failure  or  malfunction  may  result.  So  do  not  let  such  an 
article as listed below come close to the U-HSEXP.

 ·

 

PC

 ·

 

Mobile phone

 ·

 

Clock/watch

 ·

 

Credit card

 ·

 

Bank card

 ·

 

Floppy disk, etc.

} Unless the U-D7RES is connected to the U-CBS, the U-HSEXP does not 

function. So be careful.

Fig. 3

1

3

2

CAUTION

Содержание U-D7RES

Страница 1: ...and to familiarize yourself fully with the use of this system we recommend that you study this manual and the manuals of units used in combination with this system thoroughly before operating the sys...

Страница 2: ...indicates compliance with the above directives In accordance with European Directive 2002 96 EC on Waste Electrical and Electronic Equipment this symbol indicates that the product must not be dispose...

Страница 3: ...nt 1 2 1 CONNECTOR NOMENCLATURE 3 2 SYSTEM CHART 4 5 3 CABLE DISTRIBUTIONS 6 9 4 READOUT EXTERNAL TRANSMISSION OF CODED INFORMATION 10 Page CONTENTS 1 BX43 System with LED Lamp Housing 7 2 BX43 System...

Страница 4: ...y always use the provided AC adapter to power the system 3 Keep the cables away from the lamp housing and the surroundings Otherwise the cables may melt and cause an electric shock hazard Safety Symbo...

Страница 5: ...open disassemble or modify any part of the system 5 Before disposing of this product be sure to follow the regulations and rules of your local government If the system is used in a manner not specifi...

Страница 6: ...7RES connector BX3 RFAS connector POWER switch ON Depressed position OFF Out position Microscope frame hangers top bottom RS 232C connector Option connector The U CBM can be connected U HSEXP connecto...

Страница 7: ...ting the cables make sure that the POWER switch of the U CBS control box is set to OFF out position Hold each connector in the appropriate orientation and insert it all the way into the connector If a...

Страница 8: ...and the U CBS Fig 1 Note 3 Hang the U CBS control box 2 on the hangers 3 on the rear of the microscope frame Fig 2 Note 4 When this system is used with the DP21 microscope digital camera set the power...

Страница 9: ...quent pages the positions for attaching the cable holders and the method of cable distribution will be described for each microscope system The number of the cable holders used vary depending on the m...

Страница 10: ...label Align with the height of line drawn on the label Align with the top right corner of the label Banding band Provided with U HSEXP Only either cable should be used U D7RES cable BX3 RFAS cable RS...

Страница 11: ...d Provided with U HSEXP Only either cable should be used Align with the top left corner of the label Remove lamp cable slack before closing the holder Align with the height of line drawn on the label...

Страница 12: ...th the position at about 10 mm to the right of the edge of the attaching surface Align with the top right corner of the label Banding band Provided with U HSEXP Only either cable should be used U D7RE...

Страница 13: ...nables the functions interlocked with the objective and mirror unit in use except for the DP21 such as increase in the exposure time control speed addition of magnification information to the shot ima...

Страница 14: ...nient for controlling the switch from the area 3 indicated by in the figure near the coarse adjustment knob on the left or right 3 Clean the final fixing position with absolute alcohol remove the back...

Страница 15: ......

Страница 16: ...ermany 3500 Corporate Parkway Center Valley Pennsylvania 18034 0610 U S A 491B River Valley Road 12 01 04 Valley Point Office Tower Singapore 248373 31 Gilby Road Mount Waverley VIC 3149 Melbourne Aus...

Отзывы: