Страница 2: ...om falling over 7 Never turn the right and left zoom control knobs in opposite directions as malfunction may result 1 Clean all glass components by wiping gently with gauze To remove fingerprints or oil smudges wipe with gauze slightly moistened with a mixture of ether 70 and alcohol 130 A Since solvents such as ether and alcohol are highly flammable they must be handled carefully Be sure to keep ...

Страница 3: ...CONTENTS ...

Страница 4: ...TR F 0 0 3 0 0 0 Eyepiece GSWHI OX 0 Phototube SZ PT Photo eyepiece NFK3 3XLD 0 l 1 0 0 F 0 0 C l 0 0 0 0 0 0 0 C mount Video adaptt Stand SZ ST Stage plate SP BW 2 0 0 Stage Clip 0 C Dust cover 0 C Note 0 indicates the compatible components for each model ...

Страница 5: ...ter mountable Stand Fit into mounting port with inner diameter of 76 mm Microscope body mount Stage plate lOOmm frosted white on one side and black on the other side Stage Clip Pressed down from above Focusing Rack and pinion drive on ball bearing guides knob rotation tension adjustment focusing range 120 mm Epi illuminator LSGA and trans illuminator base mountable Illuminator mount Mounting to mi...

Страница 6: ...curely with a coin etc wearing eyeglasses Zoom control knob With C mount Video adapter 1 1Video adapter 1 Clamping knob Screw into the Video Camera and then mount to the Video adapter Tube length C mount adjustment ring Clamping knob Tlghten securely with a coin etc ...

Страница 7: ...ratching the glass sutfaces IOM mount Camera1 I I 1 I I Photo micro adapter L Eye shield Eyepiece 1C mount Video Camera 1 8 y C mount v 7ninn f7 Video adapter Eyepiece w 0 I 10 knob 3odv 0 Body clamping knob Stage Clip IX 1 Mount the C mount to the Video Camera and then to the Video adapter 2 Mount photomicrographic equipment in accordance with its instruction manual ...

Страница 8: ...l illuminator For SZ4045TR 1 Minimize the magnification power by turning the zoom control knobs 2 Looking through the right eyepiece bring the specimen into focus by turning the focusing knobs 3 Looking through the left eyepiece bring the specimen into focus by turning the diopter adjustment ring Fig 3 4 Maximize the magnification power by turning the zoom control knobs and bring the specimen into...

Страница 9: ...the mounting ring by turning the ring clockwise with the inscription side facing downward Fig 7 3 Gently screw the mounting ring containing the eyepiece micrometer into the eyepiece and tighten securely Fig 7 4 To remove the eyepiece micrometer twist the mounting ring Wrap the micrometer in clean soft Paper for storage The e24 mm eyepiece micrometer tan also be mounted on the GSWH15X However since...

Страница 10: ......

Страница 11: ...nd 3 above until focus is maintained even when zoomed Sr After focusing the binocular tube beforehand in accordance with the procedure listed in section q on page 4 focus deviation due to zooming will be virtually eliminated simply by selecting the Video light path minimizing the zoom magni fication power and focusing with the tube length adjustment ring For further details regarding photomicrogra...

Страница 12: ... show the magnification power at a working distance of 350 mm and 250 mm 0 25X 0 3X and 0 4X conversion lenses cannot be used with the stand due to their long working distances 2 SZEO45TR Conversion Lens for SZ6045TR Option IlOAL 0 5 186 1M AL 1 5 56 lCOAL2x 36 Sr lOOAL2X cannot be used with the Fiber Optics Ring Light Model LGR 2 3 SZ1145TR Conversion Lens for SZ1 145TR t The 73AL1 5X and 73Al2X ...

Страница 13: ...e magnification on Video monitor Zoom magnification x 0 7 x Conversion lens magnification x 0 5 x Video monitor size Picture area 1 Epikilluminator Model LSGA 3 LSGA 6 Employing a 6V 15W halogen bulb this illuminator mounts directly onto the microscope stand SZ ST A heatinsulating filter and frost glass are built in 2 Fluorescent ring illuminator Model SZ FLR This illuminator is mounted to the obj...

Страница 14: ...W bulb 9 Stand illuminator Model LSD This stand illuminator is used when intense lighting is required Either parallel or convergent luminous flux tan be selected 10 Extension tube Model SZ ET When a 0 5X conversion lens llOAL0 5X or lCOAL0 5X is used combine the extension tube with the stand 11 Eyepiece micrometer The eyepiece micrometer is mounted to the field iris diaphragm and used for length m...

Страница 15: ...Clean thoroughly Stains or dust have accumulated on the objective Diopter adjustment of the eyepieces is incomplete Complete diopter adjustment 4 Image blurs when zoomed Focus adjustment is incomplete Complete focus adjustment The focusing knob tension adjustment is too tight Loosen appropriately 5 The focusing knob is stiff 6 Poor focus during Observation due to unintentional lowering of the zoom...

Страница 16: ...er Drive Melville NY 11747 3157 U S A OLYMPUS SINGAPORE PTE LTD 491B River Valley Road 12 01 04 Valley Point Office Tower Singapore 248373 OLYMPUS OPTICAL CO U KJ LTD 2 8 Honduras Street London EClY OTX United Kingdom OLYMPUS AUSTRALIA PTY LTD 104 Ferntree Gully Road Oakleigh Victoria 3166 Australia This publication is printed on recycled Paper Printed in Japan 2000 05 M 1004 ...