background image

EN 4

En

Handling the Product

z

Use or storage of the product at the following locations may cause defective operation, defects, 
damage, fire, internal clouding, or water leakage. This should be avoided.
• Places of high temperatures, such as in direct sunlight, in a closed vehicle, etc., and/or where 

extreme differences in temperatures exist.

• Places with open fire
• Water depths in excess of 40 m
• Places with vibrations
• Places with high temperature and humidity or with severe temperature changes
• Places with volatile substances

z

This product is made of polycarbonate resin with excellent impact resistance, but it may be damaged 
by rubbing against rocks etc. It also may break when it is hit by hard objects or is dropped.

z

This product is not a case to soften impacts to the camera inside the product. When this product with 
a digital camera inside is subjected to impact or heavy objects are placed onto it, the digital camera 
may become damaged. Please handle it with sufficient care.

z

When the product is not used for a long time, the waterproof performance may drop because of 
deterioration of the O-ring etc. Before use, always perform the advance test and the final check.

z

Be careful not to apply excessive force to the port connector, TTL cable connector, zoom dial or tripod 
seat.

z

Do not push the air vent valve from inside.

z

Do not use the following chemicals for cleaning, corrosion prevention, prevention of fogging, repair or 
other purposes. When these are used for the Case directly or indirectly (with the chemicals in 
vaporized state), they may cause cracking under high pressure or other problems.

z

Do not perform operations other than specified in this instruction manual, do not remove or modify 
parts other than specified, and do not use parts other than specified.
Any trouble in taking pictures or with the equipment resulting from the above actions shall not be 
covered by the guarantee.

z

OLYMPUS IMAGING CORP. shall in no way be responsible for accidents involving immersion of a 
digital camera in water.

z

OLYMPUS IMAGING CORP. shall not pay any compensation for accidents (injuries or material 
damage) at the time of use.

Chemicals which cannot be 

used

Explanation

Volatile organic solvents, 
chemical detergents

Do not clean the Case with alcohol, gasoline, thinner or other volatile 
organic solvents or with chemical detergents etc. Pure water or 
lukewarm water is sufficient for cleaning.

Anticorrosion agent

Do not use anticorrosion agents. Pure water is sufficient when washing 
the metal parts as stainless steel and brass are used.

Commercial defogging 
agents

Do not use commercial defogging agents. Always use the specified 
desiccant silica gel.

Grease other than specified 
silicone grease

Use only the specified silicone grease for the silicon O-ring, as 
otherwise the O-ring surface may deteriorate and water leakage may 
occur.

Adhesive

Do not use adhesive for repairs or other purposes. When repair is 
required, please contact a dealer or a service station of OLYMPUS 
IMAGING CORP.

PT-E05_EN.Book  Page 4  Wednesday, June 4, 2008  12:34 PM

Содержание PT-E05

Страница 1: ...2008 http www olympus com VS724601 Printed in China PT E05 Instruction Manual Underwater Case for digital camera En PT E05 Instruction Manual PT E05_JP COVER fm 1...

Страница 2: ...accidents involving immersion of a digital camera in water In addition expenses incurred for damage of internal materials or loss of recorded contents due to water entering the camera will not be com...

Страница 3: ...s The product may deteriorate 3 Opening and closing at locations with much sand dust or dirt may impair the waterproof characteristic and cause water leakage This should be avoided 4 This product has...

Страница 4: ...gn matter 5 Apply the specified silicon grease to the O ring 6 The waterproof function is not effective if the O ring is not installed correctly When installing the O ring take care that it does not p...

Страница 5: ...ir or other purposes When these are used for the Case directly or indirectly with the chemicals in vaporized state they may cause cracking under high pressure or other problems z Do not perform operat...

Страница 6: ...le 14 2 Advance check of the Case 15 Advance test before use 15 Check the waterproof parts of the Case 15 Advance test 15 3 Installing the digital camera 16 Check the digital camera 16 Battery Confirm...

Страница 7: ...ng 29 Wipe off any waterdrop 29 Unload the digital camera 30 Wash the Case with pure water 31 Dry the Case 31 6 Maintaining the Waterproof Function 32 Remove the O ring 32 Procedure 32 Remove any sand...

Страница 8: ...er if accessories are missing or damaged Silica gel Hand strap Silicone grease O ring remover Case body Check that the O ring is normal Waterproof cap maintenance adapter Instruction manual this manua...

Страница 9: ...ont cap a Power switch lever b Front lid c Slide lock d Open close dial e INFO Info display button f MENU button g S Erase button h q Play button i Air vent valve j Pickup finder k AEL AFL button l Co...

Страница 10: ...nd strap Attach the hand strap to the Case CAUTION The Case should not be used underwater at depths that exceed 40 meters Even when the attached underwater lens port or other equipment is able to with...

Страница 11: ...s lens window When pressing the shutter lever press it gently so that there will be no movement of the camera The Case has a mode dial knob that that functions the same way as the mode dial of the dig...

Страница 12: ...2 14 54 mm 11 22 mm Controllable Not Controllable Only autofocusing is possible PPO E03 50 mm Macro Not Controllable Controllable 2 Manual focusing is possible but the MF ring rotation range is limite...

Страница 13: ...parately available UFL 2 underwater flash to the Case using an underwater optical fiber cable optional follow the procedures below Put the underwater optical fiber cable plug all the way into the opti...

Страница 14: ...cult to loosen and remove CAUTION If you cannot disconnect the TTL cable do not use force Contact Olympus for support 1 Turn the hot shoe cable connector cap inside the case counterclockwise to remove...

Страница 15: ...ly into the camera s tripod screw hole For details see How to attach the camera table to the digital camera P 19 of this manual 4 Slide the camera table all the way into the camera table loading groov...

Страница 16: ...g of the TTL cable connector is attached firmly and that the cap is screwed into the connector without loosening Advance test 1 Before loading the digital camera in the Case immerse the empty Case at...

Страница 17: ...lly charged battery before each dive CAUTION If the digital camera is loaded without removing the strap and lens cap the Case cannot be sealed properly and may leak Handle the digital camera carefully...

Страница 18: ...make sure the camera is operating correctly Open the Case 1 Slide and hold the slide lock towards the arrow direction 1 and turn the open close dial counter clockwise 2 2 Turn the open close dial to...

Страница 19: ...lens For details refer to the instruction manual for the PPO E05 Example 2 Attaching the optional underwater zoom focus gears PPZR E03 E04 E05 to the lens For details refer to the instruction manual...

Страница 20: ...e camera in the Case with the camera s built in flash popped up Refer to the UFL 2 instruction manual for the UFL 2 operation 1 The eyecup and the hot shoe cover of the digital camera can be stored in...

Страница 21: ...mera is set to a scene mode other than the AUTO or underwater modes turning the camera ON before turning the electronic flash on would cause the camera s built in flash to pop up automatically Always...

Страница 22: ...ial and mode dial on the Case pulling out the mode dial also pulls up the power switch lever so that they do not get in the way while loading the digital camera At this time set the orientation of the...

Страница 23: ...fere with the internal parts of the Case CAUTION The built in flash should be popped up before loading the camera in the Case Once the case has been sealed the built in flash cannot be popped up from...

Страница 24: ...ng the digital camera attach the zoom and focus gears to the Case s zoom and focus rings Refer to the instruction manual provided with the optional underwater lens port for details Adjust the position...

Страница 25: ...power be switched ON OFF Is the mode dial of the camera controllable When using an external electronic flash with a TTL cable check that the hot shoe cable is connected properly and that the camera s...

Страница 26: ...he grooves 2 Turn the open close dial clockwise The Case is sealed when the position of the slide lock comes right above CAUTION If the open close dial is not fully turned the Case will not be sealed...

Страница 27: ...ion After closing the case tightly check the seal between the front and rear lids and the connection between the port and case to make sure the O rings are not twisted that they sit properly in the gr...

Страница 28: ...of the Case Is there any water trickling down 4 Next immerse the Case for 30 seconds Check carefully for air bubbles Do not perform any operation yet but just observe 5 Check that no water has entered...

Страница 29: ...he image can be done by using the pick up finder or the LCD monitor When using the LCD monitor to confirm use the Live View function by pressing the u button Gently press the shutter lever When pressi...

Страница 30: ...ing suit gets inside the case and or on the camera Before opening the case or removing the port ensure that your hands or gloves are completely clean free of sand loose fibers etc Never open the case...

Страница 31: ...y do not interfere with removal of the camera and take out the camera CAUTION After opening the Case always place it so that the O ring surface is facing up If the O ring surface is faced down foreign...

Страница 32: ...igh water pressure is applied locally Before washing the Case with water remove the digital camera from it Operate the shutter lever and various buttons of this product in pure water to remove salt ad...

Страница 33: ...rcumference of the O ring lightly with your fingertips Remove attached foreign matter from the O ring groove with a clean cloth or a cotton swab Also remove any sand or dirt attached to any part of th...

Страница 34: ...es or unevenness After spreading the lubricant check visually and by touch that the O ring is not scratched and that its surface is flat If it is damaged in any way replace it with a brand new O ring...

Страница 35: ...ctions with a cotton swab and apply a thin uniform layer of silicone grease provided with this case Maintenance of the TTL Connector Cap After removing the TTL connector cap from the waterproof cap be...

Страница 36: ...foreign objects such as dust or hair 8 Be sure to insert the silica gel for prevention of fogging Use the exclusive silica gel for Olympus underwater cases 9 Confirm that the open close dial for use...

Страница 37: ...er or the like and do not dry the Case under direct sunlight Exposure to high temperatures or direct sunlight may cause deformation discoloration or breakage of the Case and deterioration of the O rin...

Страница 38: ...damage cracking or loss of elasticity Q10 What precautions need to be taken for proper maintenance of the Case A10 Pay special attention to the following items 1 Do not use the following chemicals for...

Страница 39: ...is provided with the PER E02 PPO E04 60 m 8 mm Fisheye The focus ring angle can be rotated by 360 by using the optional PPZR E05 underwater focus gear PPO E05 40 m 14 42 mm Packaged with the PPZR E06...

Страница 40: ...power switch dial mode dial control dial zoom dial camera table Polycarbonate resin Port mount pickup viewfinder frame optional bracket mount zoom dial gear TTL connector cap Aluminum Axis of operati...

Страница 41: ...PT E05_EN Book Page 40 Wednesday June 4 2008 12 34 PM...

Страница 42: ...l Underwater Case for digital camera En Mode d emploi Caisson tanche pour l appareil photo num rique Fr Bedienungsanleitung Unterwassergeh use f r Digitalkamera De Manual de instrucciones Caja estanca...

Отзывы: