Olympus PROVIS AX70 Скачать руководство пользователя страница 19

3-way camera light path.

A built-in 3-way light path enables simpli-
fied photomicrography using monochro-
matic, color and large 2D format cameras

without camera replacement.

Bright frame function for easy framing
against a dark background.

The frame control function allows easy
framing against a dark background during
such observation methods as
fluorescence and darkfield.
The brightness of the
red- or yellow-colored
frame can also be
changed for
smoother, faster
frame adjustment.

18

Fully automatic photomicrography via
multi-control box. 

The use of the multi-control box enables
fully automatic photo and video docu-
mentation.  Excellent visibility is also
offered courtesy of a plasma display,
while a touch panel keeps operation as
simple as possible.  The multi-control box
represents maximum operational comfort
– especially for frequent users of photo-
micrography or video documentation.

RESEARCH

DOCUMENTATION

U-AFPHOTO offers auto focus
capability for a wide range of
microscope techniques.

The U-AFPHOTO is equipped with a
high-performance auto focus
mechanism that accommodates a wide
range of objective magnifications
(1.25

×

-100

×

), as well as brightfield,

darkfield, fluorescence* and Nomarski
DIC* observation methods.  The
focusing speed during ordinary
brightfield observation has been raised
significantly to achieve focus in only 0.3
- 2 seconds.  In addition to the one-shot
mode, a real-time mode is included to
maintain specimen focus and
significantly enhance observation
efficiency even during objective and
microscopic technique changeovers or
specimen movement.

*The Auto focus function can be activated by

inserting an optional memory card in fluorescence
and Nomarski DIC observations.

The U-MCB can be easily operated via the touch panel while setting the
photomicrography conditions and various motorized units.  The setup
choices can be selected via the jog dial.

1. Photomicrography conditions
setting screen

Selection of camera, framing,
photomicrography mode and
exposure mode can be made via
this screen.

2. Illumination setting screen

Selection of on/off and changeover
of light control, field diaphragm, AS
and excitation light control can be
made via this screen.

3. INIT(preference) setting
screen

Selection of motorized units such
as objectives and mirror units can
be made via this screen.

4. Auto focus setting screen

In addition to accommodating many
microscopic techniques (except
phase-contrast), the system

'

s built-

in real-time mode maintains
constant specimen focus.

*Use of auto focus with AX70 requires U-AFPHOTO, AX-FOM, U-MCB and AX-PCBT.  

Since modification of AX70 unit is also required, please consult your Olympus dealer.

Содержание PROVIS AX70

Страница 1: ...UNIVERSAL INFINITY SYSTEM RESEARCH SYSTEM MICROSCOPE AX70 ...

Страница 2: ...1 Thereferenc for future mi Essential research equipment ...

Страница 3: ...exibility to accommodate tomorrow s research needs To date only one microscope fulfills all these demands the AX70 Research Microscope from Olympus Offering uncompromising performance and outstanding system integration potential the AX70 is a reference standard for future microscopes PROVIS stands for PROfessional VISion WORLD CLASS OPTICS ILLUMINATION VERSATILITY HIGH STABILITY USER COMFORT AUTOM...

Страница 4: ... adjustment for the objective in use as well as automatic observation light path selection Flexible moving spot measurement ensures optimum exposure regardless of specimen distribution A built in Super FL Auto mode offers fully automatic exposure control for fluorescence photomicrography And easy flexible framing is assured via the zoom magnification system By centralizing operation with a multi c...

Страница 5: ...microscopic methods And the system s substantial frame accepts heavy attachments for image processing and photometry applications These and many other advanced features boost the performance of the AX70 and ensure flexible system upgradability Olympus further maximizes system versatility with various accessories including the AX REXBA to optimally balance fluorescence for double stained fluorescin...

Страница 6: ...The Olympus UIS optics The new standard of excellence 5 ...

Страница 7: ...es ideal for 3D observations with a confocal laser scanning microscope With improved near ultraviolet transmission these objectives can also be used for Ca2 photometry UAPO W Series The UAPO W water immersion objectives feature a high numerical aperture Thus they enable the production of aberration free images at every specimen level from the surface down to deep sections during examination of liv...

Страница 8: ...7 Maximum quality for various microscopy applications ...

Страница 9: ...eo Enhanced Contrast and metallurgy are also available Design algorithms suited for polarized light observation The entire UIS optical system including high precision strain free POL objectives condensers and observation tube prisms has been designed to minimize reflections from lens surfaces and frame Together with dedicated Olympus optical design algorithms this ensures unmatched image contrast ...

Страница 10: ...9 A range of illuminator systems for advanced research applications ...

Страница 11: ...ral fluorescent indicators These range from 1 wavelength excitation 1 wavelength photometry 1Ex1Em to 2 wavelength excitation 2 wavelength photometry 2Ex2Em Thus the AX70 OSP100 combination can measure fluorescence intensities at a single wavelength with dual wavelength excitation using the fura 2 or BCECF indicator These advantages make it ideal for analyzing intracellular calcium ion concentrati...

Страница 12: ...11 Structural integrity for vibration resistance weighty accessories and thermal stability ...

Страница 13: ...lity the power supply was removed from the body of the microscope The AX70 was also given a heat insulating structure to reduce the temperature influence of the lamp housing on the frame These measures effectively minimize heat induced frame flexure on the AX70 HIGH STABILITY Application example Video Enhanced Contrast A low contrast sample unidentifiable in ordinary microscopic observation can be...

Страница 14: ...Maximum operator comfort at all times 13 ...

Страница 15: ...s The AX70 also has enough space between the stage surface and arm to easily accommodate large and thick specimens Improved operational ease for enhanced manipulation The revolutionary Y shape of the AX70 frame offers unique user benefits It not only allows the operator s forearms to be supported by the worktable or bench surface but also provides more working space As a result micromanipulators c...

Страница 16: ...Automation facilitates research microscopy 15 ...

Страница 17: ...ion emission spectrum Efficient heat and IR removal in the collector lens protects interference exciter filters from unnecessary energy The automation capability RS232C GPIB of the PROVIS AX70 makes it an ideal base for automated FISH imaging stations The combination of motorized units with a multi control box automates the entire microscopic procedure A motorized universal condenser allows quick ...

Страница 18: ...A 1 2 zoom magnification change system significantly eases zooming and trimming of a desired section to significantly increase framing options flexibility for video recording U PHOTO Universal Photo System The U PHOTO Universal Photo System is an automatic photomicrography system that provides fully automatic functions for photomicrography These include a flexible spot measurement function a Super...

Страница 19: ...s The focusing speed during ordinary brightfield observation has been raised significantly to achieve focus in only 0 3 2 seconds In addition to the one shot mode a real time mode is included to maintain specimen focus and significantly enhance observation efficiency even during objective and microscopic technique changeovers or specimen movement The Auto focus function can be activated by inserti...

Страница 20: ...AX REXBA allows adjustment of excitation light unnecessary irradiation is prevented and damage to the specimen is minimized 3 The 25EBFB G filter accommodates a double stained fluorescing specimen using two types of fluorochromes FITC TRITC and FITC Texas Red This filter is designed for general use with double stained specimens with G B excitation The 25EBFU B filter designed for U B excitation is...

Страница 21: ...C TRITC UPLAPO40 PE3 3 Optical center adjuster AX OCA The AX OCA effectively eliminates the deviations during multiple exposure Specimens viewed with AX REXBA TRITC enhanced FITC enhanced Precise correction for image deviation in multiple exposure ...

Страница 22: ... selector Observation tubes The AX Series observation tubes range from widefield binocular to super widefield erect image trinocular corresponding to various observation needs PM30 automatic photomicrography system The exclusive Super FL Auto mode provides fully automatic exposure control for effortless fluorescence photo micrography The Auto mode accommodates all other observation methods and a h...

Страница 23: ...path 80 of all light goes to camera optical path during exposure BI video camera direct video camera 2 photometry 20 0 80 0 100 0 0 0 0 100 0 0 20 0 0 80 0 20 0 80 video camera 2 is mounted to large format port via U TVL Camera optical path 35mm left large format 35mm right 100 0 0 0 100 0 0 0 100 When using video camera 2 35mm left 35mm right 100 0 0 100 Photo magnification 35mm camera 2 5x 5x la...

Страница 24: ...out any obligation on the part of the manufacturer ISO9001 Certification Design and production adheres to ISO9001 international quality standard ISO 9001 Accredited by the Dutch Council for Accreditation ISO14001 Design and production at the Olympus Optical Co Ltd Ina Plant conforms with ISO14001 specifications for environmental management systems Certification ISO 14001 008 U K A S ENVIRONMENTAL ...