Olympus PR-V223Q Скачать руководство пользователя страница 17

An Essential Tool to achieve a New Level of Efficiency 
in Biliary-Pancreatic Procedures.  Designed to Enhance 
the Revolutionary Exchange Capability of the V-System. 

Specially coated to insure 
smooth wire manipulation

To ensure smooth passage through tight strictures in the bile 
duct, the distal 500mm from the tip is coated with a special 
hydrophilic coating that provides exceptional lubricity.  
The balance of the guidewire is coated with PTFE for 
smoother exchange. These coatings allow the 
guidewire to be manipulated easily

130mm

Ring-marker section

Spiral-marker section

Ring-markers are visible from 50mm 
to 120mm from the distal end to 
help determine duct penetration.

50mm

120mm

400mm

2700mm / 4500mm

PTFE Coating

50mm

120mm

400mm

2700mm / 4500mm

PTFE Coating

Hydrophilic Coating Length:

500mm

Hydrophilic Coating Length:

500mm

Note:  

This instrument meets the recognized standard for high 

frequency electrosurgical leakage current - ANSI/AAMI HF-18(1993), 

4.2.5.2 and 5.2.5.2 - when used with an Olympus sphinctetorome. 

Removal of the guidewire is not necessary during sphincterotomy.

All Designs are Optimized to Assure Smooth, 
Efficient Guidance of Devices to the Bile And Pancreatic Ducts

Two-step  markers ensure visibility 
in the endoscopic field of view

Two-step markers on the Linear GuideV make 
it easy to confirm the movement and position 
of the guidewire within the endoscopic field of view.

Two distal tip configurations to suit 
different techniques and preferences

The LinearGuideV comes in two tip 
configurations — straight and angulated. 
The straight tip can be used for a variety of purposes, 
while the angulated tip is best suited for passing a 
stricture and for selective insertion.  
Choose the tip that best suits your techniques 
and preferences.

The LinearGuideV has been designed to provide 
superior insertion capability, maximum endoscopic 
visibility, and easy device exchange.  When the 
LinearGuideV’s spiral markings are visible from 
the scope tip, the guidewire can be locked to 
simplify device exchange. 

Endoscopic visibility of the spiral-
markers indicates that 
LinearGuideV may be locked in 
the V-Groove.

Содержание PR-V223Q

Страница 1: ...Single Use Cannula V Single Use Cannula V ...

Страница 2: ... when to raise the elevator to lock the guidewire C Hook Now endoscopists have the option to manipulate guidewires and devices V Marking Indicates when to raise and lower the V Groove forceps elevator The Innovative V System Design Lets You Proceed with Confidence and Efficiency The Innovative V System Exchange Capability Makes Olympus ERCP Cannulae Even More Efficient Excellent visibility under f...

Страница 3: ...t Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng District Beijing 100005 China 117071 Moscow Malaya Kaluzhskaya 19 bld 1 fl 2 Russia 31 Gilby Road Mount Waverley VIC 3149 Australia 2 Corporate Center Drive Melville N Y 11747 3157 U S A Spacifications Model Distal tip diameter Portion Diameter Shape of the distal end 1700mm Working length Compatible guidewire PR V414Q PR...

Страница 4: ...Single Use 3 Lumen Extraction Balloon V ...

Страница 5: ...s that the device tip has reached the distal end of the scope and the V Groove forceps elevator may be lowered When withdrawing the device from the scope the same marking indicates when to raise the elevator to lock the guidewire The V System is a complete system that integrates Olympus endoscopes and EndoTherapy devices The revolutionary V System design offers the option of guidewire manipulation...

Страница 6: ...syringes for reliable inflation Multiple balloon sizing Injection Lumen 0 035 Guidewire Lumen Air Lumen For easy confirmation of balloon position during fluoroscopy two radiopaque bands are incorporated one at the distal end of the balloon and one at the proximal end Three pre measured clearly marked syringes enable precise inflation of each balloon to the desired size Much easier and much more re...

Страница 7: ...tions design and accessories are subject to change without any notice or obligation on the part of the manufacturer Shinjuku Monolith 3 1 Nishi Shinjuku 2 chome Shinjuku ku Tokyo 163 0914 Japan Postfach 10 49 08 20034 Hamburg Wendenstrasse 14 18 20097 Hamburg Germany 6100 Blue Lagoon Drive Suite 390 Miami Florida 33126 2087 U S A Keymed House Stock Road Southend on Sea Essex SS2 5QH England 491B R...

Страница 8: ...Single Use Retrieval Basket V Single Use Retrieval Basket V ...

Страница 9: ...ing is located on the proximal side of the sheath When this marking reaches the channel port on the scope s control section it indicates that the device tip has reached the distal end of the scope and the V Groove forceps elevator may be lowered When withdrawing the device from the scope the same marking indicates when to raise the elevator to lock the guidewire The Innovative V System Design Lets...

Страница 10: ...ingapore 248373 Room 1520 1527 Ocean Centre 5 Canton Road Tsimshatsui Kowloon Hong Kong Room 1401 East Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng District Beijing 100005 China 117071 Moscow Malaya Kaluzhskaya 19 bld 1 fl 2 Russia 31 Gilby Road Mount Waverley VIC 3149 Australia 2 Corporate Center Drive Melville N Y 11747 3157 U S A BML 110A 1 Printed in Japan F1091SB...

Страница 11: ...Single Use 2 Lumen Sphincterotome V Single Use 3 Lumen Sphincterotome V ...

Страница 12: ...ted on the proximal side of the sheath When this marking reaches the channel port on the scope s control section it indicates that the device tip has reached the distal end of the scope and the V Groove forceps elevator may be lowered When withdrawing the device from the scope the same marking indicates when to raise the elevator to lock the guidewire The V Sheath allows the endoscopist complete d...

Страница 13: ...cases in which cannulation is difficult due to strictures or when insertion into the minor papilla is required The tapered tip CleverCut3V is compatible with a 0 025 diameter guidewire The distal ends of the CleverCut2V and CleverCut3V are pre curved to achieve stable cannulation capability This distal configuration also facilitates easy positioning of the knife into the papilla The CleverCut2V an...

Страница 14: ...ct Beijing 100005 China 117071 Moscow Malaya Kaluzhskaya 19 bld 1 fl 2 Russia 31 Gilby Road Mount Waverley VIC 3149 Australia 2 Corporate Center Drive Melville N Y 11747 3157 U S A Spacifications Model Maximum insertion portion diameter Distal tip diameter Lumen type KD V411M 0320 KD V411M 0330 KD V411M 0720 KD V411M 0725 KD V411M 0730 KD V411M 1520 KD V411M 1530 KD V411M 3030 KD V431M 0720 KD V43...

Страница 15: ...DISPOSABLE GUIDEWIRE ...

Страница 16: ...esign Lets You Proceed with Confidence and Efficiency Schematic of the V Groove locking mechanism V System device replacement procedure Conventional scope TJF 160 V System scope TJF 160V LinearGuideV Guidewire V Groove The V System is a complete system that integrates Olympus endoscopes and EndoTherapy devices The revolutionary V System design offers the option of guidewire manipulation by the phy...

Страница 17: ...2 5 2 and 5 2 5 2 when used with an Olympus sphinctetorome Removal of the guidewire is not necessary during sphincterotomy All Designs are Optimized to Assure Smooth Efficient Guidance of Devices to the Bile And Pancreatic Ducts Two step markers ensure visibility in the endoscopic field of view Two step markers on the LinearGuideV make it easy to confirm the movement and position of the guidewire ...

Страница 18: ...Point Office Tower Singapore 248373 Room 1520 1527 Ocean Centre 5 Canton Road Tsimshatsui Kowloon Hong Kong Room 1401 East Tower Gong Yuan No6 Royal Palace No6 Gon YuanXijie JianGuoMenNei DongCheng District Beijing 100005 China 117071 Moscow Malaya Kaluzhskaya 19 bld 1 fl 2 Russia 31 Gilby Road Mount Waverley VIC 3149 Australia 2 Corporate Center Drive Melville N Y 11747 3157 U S A Printed in Japa...

Отзывы: