background image

MOTORIZED UNITS

41

51

77

206

310.5

77

133

341.6

334

56

56

169

92

54

70

4

75.5

82.3

50

91.5

210

70

100

214

104

33.6

3

BXFMA-F

Motorized illumination with power focus

A motorized microscope unit for integration with your equipment. Motorized operations such as revolving nosepiece up/down, objective lens
switching, aperture diaphragm open/close, and brightfield/darkfield switching are accomplished with this component. 
Several microscopic operations are totally controlled from an external unit by combining this component with an auto focus unit.

U-FH

Focus adjustment knob unit

U-IFFH

Focus adjustment knob interface

Unit: mm

Weight: 7.6kg

Weight: 1450g

Weight: 760g

* Consult your Olympus dealer about the mounting dimensions.

Содержание Microscope

Страница 1: ...MICROSCOPE COMPONENTS GUIDE Choosing The Ideal UIS2 Optics Components For Your Equipment 2 0 0 6 1 1 ...

Страница 2: ...such diverse fields as research inspection and production to take advantage of the quality flexibility and outstanding optical performance of the UIS2 Optical System That s why installing Olympus microscope components is quite simply the right choice for your equipment 1 ...

Страница 3: ... housing U UVF248LB U LH80HBXE 42 OPTICAL TERMINOLOGY 43 46 WELCOME TO UIS2 UIS OPTICS 3 4 SYSTEM DIAGRAM 5 6 UIS2 UIS OBJECTIVE LENSES 7 18 M Plan SemiApochromat MPLFLN series 8 Long WD M Plan SemiApochromat LMPLFLN series 9 M Plan Achromat MPLN series 10 LCD Long WD M Plan SemiApochromat LCPLFLN LCD series 11 M Plan Apochromat MPlanApo series 12 Super Long WD M Plan Achromat SLMPlan series 12 IR...

Страница 4: ...es of infinity corrected optics This system known as infinity corrected optics offers a number of advantages There is no change in magnification even when the distance between the objective lens and tube lens is altered With the total magnification remaining constant there is no image aberration even when prisms or sliders are interposed between the objective lens and the tube lens As thousands of...

Страница 5: ...berration refer to the optical terminology at the end of this document 2 Objective lenses with excellent image parcentricity High power SemiApochromatic UIS2 objective lenses make the centration tolerance between objective lenses on the microscope nosepiece keep the image within the enter of the field of view even with digital cameras 50x or higher power in both MPLFLN and LMPLFLN series 3 Improve...

Страница 6: ... WHN Eyepieces SWH Eyepieces BX RLA2 ND FS AS BX URA2 U RCV U KMAS SZX TLGAD U DULHA BX KMA BX KMA ESD U POTP3 FS AS U TV0 25xC U TV0 35xC 2 U TV0 5xC 3 U TV0 63xC U TMAD U BMAD U SMAD U FMT U CMAD3 Video camera C mount Video camera S mount 2 3 Video camera F mount Video camera B mount 2 3 U TV1x 2 Revolving nosepiece Refer to pages 34 35 Refer to pages 19 21 Refer to page 22 Refer to pages 23 28 ...

Страница 7: ...HGAPO U LH100HG BF DF objective lenses BF objective lenses BD M AD Refer to pages 38 40 Refer to page 26 Refer to pages 7 18 Refer to page 35 BX REMCB is also available for BX RLAA motorized revolving nosepiece control refer to page 39 See manual U D6REMC U P5REMC U D5BDREMC U AFA1M U LH100 3 U LH100L 3 U LH100HG U LH75XEAPO U FWR U HSTR2 BX UCB Objective lenses BXFMA F U IFFH U FH PC U RMT ø32fil...

Страница 8: ...ve lenses is standardized the position of the DIC prism does not have to be switched when changing the magnification a MPLN series M Plan Achromat P 10 Plan Achromat objective lenses providing excellent image flatness up to F N 22 a LCPLFLN LCD series LCD Long WD M Plan SemiApochromat P 11 Perfect objective lens series for observation of LCD panels and other samples through a glass substrate Aberr...

Страница 9: ...ø15 2 ø17 8 ø26 ø26 ø12 1 WD 3 1 4 5 41 9 45 35 1 WD 1 45 4 8 44 38 4 42 4 42 61 4 8 45 WD 1 44 41 78 40 8 36 8 MPLFLN1 25x MPLFLN2 5x MPLFLN5x MPLFLN10x MPLFLN20x MPLFLN50x MPLFLN100x MPLFLN 1 25x 0 04 3 5 145 122 12 5 17 6 870 MPLFLN 2 5x 0 08 10 7 72 106 25 8 8 220 25 10 6 220 MPLFLN 5x 0 15 20 0 36 51 5 50 4 4 59 50 5 3 59 MPLFLN 10x 0 30 11 0 18 68 1 100 2 2 15 100 2 7 15 MPLFLN 20x 0 45 3 1 ...

Страница 10: ... 0 9 73 200 1 1 6 1 200 1 3 6 1 LMPLFLN 50x 0 50 10 6 3 6 77 500 0 44 2 5 500 0 53 2 5 LMPLFLN 100x 0 80 3 4 1 8 94 1000 0 22 0 87 1000 0 27 0 87 Numerical Aperture Working distance mm Weight g Focal distance f mm Total magnifications Practical field of view mm Depth of focus µm Total magnifications Practical field of view mm Depth of focus µm UIS2 objective lenses Widefield eyepiece WHN10x Field ...

Страница 11: ...g distance mm Focal distance f mm Weight g Total magnifications Practical field of view mm Depth of focus µm UIS2 objective lenses Widefield eyepiece WHN10x Field Number 22 Objective lens magnification Screw W20 32x0 706 0 8 x1 36 ø20 32 ø20 32 ø20 32 ø6 ø11 9 ø15 8 ø24 ø21 ø24 ø24 ø16 ø12 ø10 5 45 4 5 23 4 25 WD 20 WD 10 6 34 4 4 5 45 32 71 28 8 33 6 4 5 43 7 45 WD 1 3 37 2 41 3 42 4 ø20 32 ø20 3...

Страница 12: ...LFLN 100xLCD 0 85 0 9 1 8 185 1000 0 22 0 79 1000 0 27 0 79 Numerical Aperture Working distance mm Focal distance f mm Weight g Total magnifications Practical field of view mm Depth of focus µm Total magnifications Practical field of view mm Depth of focus µm UIS2 objective lenses Widefield eyepiece WHN10x Field Number 22 Super widefield eyepiece SWH10x Field Number 26 5 Objective lens magnificati...

Страница 13: ...UIS objective lenses Widefield eyepiece WHN10x Field Number 22 Super widefield eyepiece SWH10x Field Number 26 5 Objective lens magnification Screw W20 32x0 706 0 8 x1 36 Unit mm Super Long WD M Plan Achromat SLMPlan series Plan Achromat objective lenses with high magnification and super long working distance Two magnifications 20x and 50x are available For 5x or 10x objective lenses select from t...

Страница 14: ...8 ø20 32 ø15 37 45 4 5 ø20 32 ø4 95 ø12 2 45 ø26 ø26 39 WD 6 37 5 36 9 32 9 ø12 5 ø15 6 ø18 4 7 ø20 32 41 6 WD 3 4 40 8 ø26 LMPlan5xIR LMPlan10xIR LMPlan20xIR LMPlan50xIR LMPlan100xIR Unit mm MPlan100xIR LMPlan 5xIR 0 10 20 0 36 73 50 4 4 98 LMPlan 10xIR 0 25 18 5 18 73 100 2 2 18 LMPlan 20xIR 0 40 8 1 9 110 200 1 1 6 1 LMPlan 50xIR 0 55 6 0 3 6 115 500 0 44 2 2 LMPlan 100xIR 0 80 3 4 1 8 122 1000...

Страница 15: ...0 1 0 1 8 98 9 1000 0 22 0 73 1000 0 27 0 73 MPLFLN 150xBD 0 90 1 0 1 2 104 8 1500 0 15 0 6 1500 0 18 0 6 Numerical Aperture Working distance mm Focal distance f mm Weight g Total magnifications Practical field of view mm Depth of focus µm Total magnifications Practical field of view mm Depth of focus µm UIS2 objective lenses Widefield eyepiece WHN10x Field Number 22 Super widefield eyepiece SWH10...

Страница 16: ...e lens magnification MPLFLN5xBDP MPLFLN10xBDP MPLFLN20xBDP MPLFLN50xBDP MPLFLN100xBDP ø26 ø26 ø26 ø22 4 ø16 ø29 3 ø32 ø26 ø22 ø16 8 ø27 ø32 ø27 5 ø22 ø17 ø28 5 ø32 45 WD 12 WD 6 5 WD 3 4 5 33 31 5 31 30 25 38 5 4 5 45 37 36 5 34 1 4 5 42 39 5 39 35 97 45 ø26 ø26 ø32 ø27 5 ø20 ø32 ø27 5 ø20 WD 1 WD 1 44 4 5 45 41 4 5 45 44 41 M Plan SemiApochromat BDP BDP Brightfield Darkfield Polarizing MPLFLN BDP...

Страница 17: ...PLFLN 50xBD 0 50 10 6 3 6 85 500 0 44 2 5 500 0 53 2 5 LMPLFLN 100xBD 0 80 3 3 1 8 102 1000 0 22 0 87 1000 0 27 0 87 Numerical Aperture Working distance mm Focal distance f mm Weight g Total magnifications Practical field of view mm Depth of focus µm Total magnifications Practical field of view mm Depth of focus µm UIS2 objective lenses Widefield eyepiece WHN10x Field Number 22 Super widefield eye...

Страница 18: ...g distance mm Focal distance f mm Weight g Total magnifications Practical field of view mm Depth of focus µm UIS2 objective lenses Widefield eyepiece WHN10x Field Number 22 Objective lens magnification Screw W26x0 706 Unit mm MPLN10xBD MPLN20xBD MPLN100xBD ø26 ø26 ø26 ø32 ø30 5 ø29 3 ø16 ø32 ø32 ø29 ø23 6 ø17 ø27 ø26 ø22 ø16 8 4 5 WD 12 45 33 31 5 31 30 25 45 38 5 WD 6 5 4 5 37 36 5 34 01 4 5 WD 1...

Страница 19: ... at the highest level while providing high N A MPlanApo100xBD 0 9 0 31 1 8 180 1000 0 22 0 59 1000 0 27 0 59 Numerical Aperture Working distance mm Focal distance f mm Weight g Total magnifications Practical field of view mm Depth of focus µm Total magnifications Practical field of view mm Depth of focus µm UIS objective lenses Widefield eyepiece WHN10x Field Number 22 Super widefield eyepiece SWH...

Страница 20: ...be integrated into other equipment Attach to the equipment by rear bolt mounting screw or pillar mounting hole 19 MICROSCOPE SYSTEM BXFM Weight 1 9kg Unit mm 98 110 80 58 5 0 5 13 13 55 23 7 4 M4 depth9 4 M4 depth7 Pillar mount hole center 66 2 16 17 17 34 36 35 82 4 M8 depth8 Bolt mount screw 0 5 17 100 124 36 ø32H8 Pillar mount hole 84 Stroke 2A00002 ...

Страница 21: ...7 3 5 Holder mounting position Pillar axis Revolving nosepiece mounting position Objective lens mounting position Stroke Specimen position 180 587 220 180 249 130 87 5 83 ø 32 40 3 5 45 165 11 17 47 stroke 124 Specimen surface BXFM combination sample BXFM F BXFM ILH BXFM ILHSPU TR30 2 BX RLA2 U LH100L 3 Weight 8 2kg exclude objective lens Unit mm For installation dimensions refer to those for the ...

Страница 22: ... exclude objective lens Unit mm BXFM S BXFM F BXFM ILHS Compact focusing unit suitable for building into existing equipment Weight 2 4kg Unit mm 20 Stroke 7 23 Light axis 45 40 84 141 59 106 Holder mounting position Pillar axis Revolving nosepiece mounting position Objective lens mounting position Specimen position For installation dimensions refer to those for the BXFM F page 19 ...

Страница 23: ...f tube 2 Vertical pole diameter ø40mm 3 Horizontal poles diameters ø25mm both upper and lower poles 4 Stroke Horizontal 234mm Vertical 205mm 5 Movement range Horizontal 541 435 106 mm max Vertical pole BXFM S optical axis 6 Maximum specimen weight Forward 10kg within 90 degree area Transverse direction 6kg Backward direction 7kg at maximum stroke 7 Weight 30kg Major specifications SZ2 STU2 Univers...

Страница 24: ...FR Frost filter slider 20 U 25L42 UV cut filter 20 U PO3 Polarizer slider for reflected light 71 U POTP3 Polarizer slider for reflected light 71 with tint plate U AN360 3 360 rotatable analyzer slider 79 U AN Analyzer slider for reflected light 50 U DICR DIC slider for reflected light 130 U DICRH DIC slider for reflected light 130 high resolution type U DICRHC DIC slider for reflected light 130 hi...

Страница 25: ...SD model is also available Weight 3 1kg Unit mm Combine SZX TLGAD when using fiber illumination 88 ø70 108 Cable length 260 5mm 312 5 250 30 84 3 5 41 Illuminator mounting position Revolving nosepiece mounting position Unit name Description Weight g U 25LBD LBD filter slider 20 U 25IF550 IF550 filter slider 20 U 25ND6 ND filter 20 U 25ND25 ND filter 20 U 25FR Frost filter slider 20 U 25L42 UV cut ...

Страница 26: ...25ND6 ND filter 20 U 25ND25 ND filter 20 U 25FR Frost filter slider 20 U 25L42 UV cut filter 20 U PO3 Polarizer slider for reflected light 71 U POTP3 Polarizer slider for reflected light 71 with tint plate U AN360 3 360 rotatable analyzer slider 79 U AN Analyzer slider for reflected light 50 U DICR DIC slider for reflected light 130 U DICRH DIC slider for reflected light 130 high resolution type U...

Страница 27: ...0 5 130 18 5 8 83 5 65 25 65 40 8 3 0 115 75 20 135 depth dimension for installation 146 5 85 5 107 37 Weight 880g Power supply unit BH2 RFL T3 or U RFL T200 and power cable UYCP are necessary for 100W mercury lamp housings These items are sold separately BH2 RFL T3 dimensions 120 W x290 D x225 H weight approx 5kg U RFL T200 for EU countries dimensions 150 W x295 D x200 H weight approx 4 8kg Power...

Страница 28: ...luminators can be used with fiber illumination Unit mm 1 700 Unit mm Weight 315g U RCV DF converter for BX URA2 U RMT Extension cord Weight 200 g Light guide mount hole ø12 Weight 135g SZX TLGAD Transmitted light guide adapter U LGAD Fiber adapter for reflected light observation Light guide mount hole ø12 Weight 390g Weight 2 2kg TH4 100 200 External power supply TH4 HS Hand switch Weight 140g 14 ...

Страница 29: ...S2 Light source LG SF Light guide U DULHA Double lamp house adapter 8 76 235 251 10 10 126 86 130 ø15 Light guide mounting position Groove Width3 Depth1 10 ø10 1 ø13 ø12 ø25 ø15 30 31 61 25 20 1 000 The types of model varies by country in use 202 171 82 88 ø140 Weight 1 2kg ...

Страница 30: ...r IR Single port tube with lens When the visual observation is not needed and only video observation is required a single port tube with a built in telan lens can be attached directly to the video port Unit mm Unit mm U TR30 2 22 30 50 76 100 0 20 80 0 100 Inverted 1600 U TR30IR 22 30 50 76 100 0 0 100 Inverted 1600 U ETR 4 22 30 50 76 100 0 0 100 Erect 1900 Field Number F N Inclination angle degr...

Страница 31: ...R Super widefield erect image tilting trinocular tube U SWETR Super widefield erect image trinocular tube U SWTR 3 26 5 24 50 76 100 0 20 80 0 100 Inverted 2300 U SWETR 26 5 24 50 76 100 0 0 100 Erect 4200 MX SWETTR 26 5 0 42 50 76 100 0 0 100 Erect 4200 Unit mm Field Number F N Inclination angle degree Interpupillary distance mm Name Light path selector eyepiece video port Observation image Weigh...

Страница 32: ...2x Provides 1x and 2x intermediate magnifications Weight 1 3kg U CA Magnification changer Provides 1x 1 2x 1 6x and 2x intermediate magnifications Weight 1 3kg BI PT 100 0 20 80 U TRU Trinocular intermediate attachment Intermediate attachment which divides the light path allowing attachment of both digital and video cameras ø 1 4 0 150 88 52 37 183 9 106 9 52 37 150 ø 1 4 0 58 2 ...

Страница 33: ... Eyepoint adjuster Raises eyepoint by 30mm Weight 1 2kg U APT Arrow pointer Projects an arrow into the field of view Unit mm 88 38 51 mount face 151 57 ø 1 4 0 1 32UN 17 53 4 5 170 5 mount face 182 ø44 ø25 ø44 ø30 0 92 tolerence from light axis 120 45 45 3 15V0 2A 21 2 115 8 45 89 30 88 Transmitted side port side port 100 0 Transmitted side port side port 70 30 with use of U MBF3 Light path select...

Страница 34: ...cale lines 1mm per rotation of the shift ring the circumference of which is divided into 100 graduations Measuring range 10mm objective lens magnification 5 by combined use of the zoom compensation ring and the provided stage micrometer Compensation ring clamping screw Magnification compensation scale Actual size Actual size mm Measured value mm Objective lens magnification Repeatability Repeatabi...

Страница 35: ...ces for BF objective lenses Choose from following 6 types For motorized nosepieces refer to motorized unit page U D6RE Sextuple revolving nosepiece with slider slot for DIC U D6RE ESD Sextuple revolving nosepiece with slider slot for DIC with ESD treatment ø84 40 8 26 5 60 9 87 4 40 83 ø102 4 104 40 48 2 114 4 38 76 4 Weight 520g Weight 800g Weight 980g U 5RE 2 Quintuple revolving nosepiece Unit m...

Страница 36: ...mount BF objectives BD M AD enables attachment of brightfield objective lenses For motorized nosepieces refer to motorized unit page U 5BDRE Quintuple revolving nosepiece for BF DF U D6BDRE Sextuple revolving nosepiece for BF DF with slider slot for DIC U P5BDRE Centerable quintuple revolving nosepiece BD M AD Adapter to mount BF objectives Weight 800g Weight 1kg U D5BDRE Quintuple revolving nosep...

Страница 37: ...itching to a low magnification after focusing at a high magnification objective lens C mount video camera ports Allows direct attachment of a C mount video camera Four types are provided 0 63x 0 5x 0 35x and 0 25x All models feature a focus adjustment function U TV0 25xC C mount video port with 0 25x lens U TV0 35xC 2 C mount video port with 0 35x lens U TV0 5xC 3 C mount video port with 0 5x lens...

Страница 38: ...V1x 2 Focus by amount of screwing into U TV1x 2 Unit mm Unit mm U CMAD3 C mount adapter U BMAD Bayonet mount adapter U TMAD T mount adapter U FMT F T mount adapter U SMAD Sony mount adapter Weight 70g Weight 30g It must be combined with U TMAD Image plane Image plane M56X2 49 ø42 ø64 48 30 3 ø64 ø48 60 38 40 4 Image plane M56X2 17 53 M56X2 1 32UN ø30 ø44 5 ø64 4 80 5 60 5 48 7 20 4 Image plane 4 2...

Страница 39: ...kfield observations as well as aperture diaphragm closing opening The BX UCB control unit has an RS232C connector allowing control via a PC For method of attaching illuminator refer to page 24 BX RFAA Motorized universal reflected light illuminator Reflected light fluorescence illuminator with simultaneous attachment of six mirror units Incorporates motorized mirror unit changeover and shutter Mot...

Страница 40: ...using U LH100 3 to the BX UCB U HSTR2 Hand switch Weight 1 0kg Cable length 2000mm Weight 370g BX UCB Control unit Motorized units including motorized illuminator and auto focus unit can be totally controlled from BX UCB BX REMCB Control box for motorized nosepiece and BF DF illuminator BX RLAA and U D5BDREMC U D6REMC U P5REMC can be controlled from U HSTR2 or direct from the computer keyboard via...

Страница 41: ...2 58 4 14 8 62 5 71 Consult your Olympus dealer about the motorized focus Cable length 2000mm Weight 3 3kg U AFA1M Active auto focus unit Weight 1 0kg U FWR Motorized reflected filter wheel Accomplish maximum 6 filter position exchange 2000 147 9 180 5 130 58 5 24 5 42 30 5 ...

Страница 42: ... revolving nosepiece up down objective lens switching aperture diaphragm open close and brightfield darkfield switching are accomplished with this component Several microscopic operations are totally controlled from an external unit by combining this component with an auto focus unit U FH Focus adjustment knob unit U IFFH Focus adjustment knob interface Unit mm Weight 7 6kg Weight 1450g Weight 760...

Страница 43: ...ght guide 34 30 4 105 8 2000 200 0 or 5000 200 0 39 5 6 5 5 ø70 196 8 196 ø30 ø39 4 1 32 UNF C Mount Thread 45 distance between mounting positions 102 5 U UVF248IM UV248 compatible intermediate tube U UVF2FB 5FB UV quartz light guide U UVF248LB U LH80HGXE UV248 compatible light source box Mercury Xenon lamp housing 8 170 227 41 240 210 3 4 ø4 5 ø8 C bore 5 Deep 4 ø4 5 ø13 C bore 5 Deep 150 150 45 ...

Страница 44: ...ob M video camera adapter Monitor magnification M video monitor Total magnification on the video monitor M ob Objective lens magnification M video camera adapter Projected magnification for video camera adapter including photo eyepiece refer to Figure 1 Refer to Figure 3 for Monitor magnification Practical field of view for video monitor observation M ob Objective lens magnification M video camera...

Страница 45: ...g formula is generally used for determing resolution ε 0 61 λ Reyleigh formula N A λ Wavelength or radiation in use λ 0 55µm is used for visible light N A Objective lens N A Example MPLFLN100 N A 0 90 λ 0 55µm ε 0 61 λ 0 3355 0 3355 0 37µm N A N A 0 90 8 Focal depth of Microscope The focal depth refers to the depth of the specimen layer which is in sharp focus at the same time even if the distance...

Страница 46: ...axial object point enter a lens the light rays with a larger numerical aperture N A are subjected to stronger refraction power and cross the optical axis in positions with larger differences from the ideal image formation position The aberration caused this way by different image forming positions due to differences in N A of axial light rays is called spherical aberration Spherical aberration is ...

Страница 47: ...glass materials are used e g for apochromats MPlanApo in Olympus to eliminate chromatic aberration in a wide range from violet light g rays with wavelength of 435 nm to red light c rays with wavelength of 656 nm 9 3 Wavefront Aberration Since a long time ago aberrations have been used in geometric optics which considers light as light rays Microscope optical systems are often used for observation ...

Страница 48: ...Specifications are subject to change without any obligation on the part of the manufacturer Printed in Japan M1606E 1106B OLYMPUS CORPORATION has obtained ISO9001 14001 ...