CMOS color camera OLYMPUS LC30

6

1.4

Operating and storage conditions

Please operate and store your camera under the following conditions:

The maximum permissible range for the ambient temperature during camera

operation is +5°C to +40°C.

The maximum permissible relative humidity during camera operation is 80 %

(condensation free).

When the camera is stored or transported, the ambient temperature must be

kept between -20°C and +60°C.

Indoor use only.

Maximum altitude: 2000 m.

Содержание LC30

Страница 1: ...English Optical Microscope Accessory To obtain optimum performance of this camera and to ensure the safety study this manual thoroughly before operating the camera and keep it on hand during operation...

Страница 2: ...ndirect special incidental or consequential damages arising out of purchase or use of this manual or the information contained herein No part of this document may be reproduced or transmitted in any f...

Страница 3: ...oiding personal injuries 8 2 3 Avoiding device damage 9 3 System environment 10 3 1 General remarks 10 3 2 Microscopes and camera adapters 12 3 3 PC 13 3 4 Software 14 4 Installation 15 4 1 Step 1 Ins...

Страница 4: ...e cap Camera with protective cap USB 2 0 cable USB 2 0 cable Installation Manual Installation Manual USB 3 0 PCI express card with driver on CD and power supply cable not included in the scope of supp...

Страница 5: ...ope by a C mount The ICC profile technology guarantees an optimal color mapping Binning modes The OLYMPUS LC30 has three binning modes In binning mode the camera s CMOS sensor combines neighboring pix...

Страница 6: ...tions The maximum permissible range for the ambient temperature during camera operation is 5 C to 40 C The maximum permissible relative humidity during camera operation is 80 condensation free When th...

Страница 7: ...re and during the installation 2 1 Explanation of the symbols used Personal injuries Device damage General notes The warning sign and the word WARNING indicate dangerous situations that can lead to se...

Страница 8: ...In the case of a fire the material of the camera can give off toxic gases When these are inhaled it can cause irritation of the respiratory passages and damage to them Wear respiratory protection when...

Страница 9: ...ensitive and must not come into contact with bare hands or any other objects otherwise the acquisitions will be impaired by fingerprints or scratches Remove dust from the protective glass carefully wi...

Страница 10: ...30 can be used in combination with many available micro scopes However its performance in combination with non Olympus microscopes has not been tested Application context Explanation Countermeasure Us...

Страница 11: ...y closed Switch on the shading correc tion or decrease illumination intensity and open the AS diaphragm Observing high contrast samples High contrast samples may cause the auto exposure to fail result...

Страница 12: ...era adapters with the magnification factor 0 35 or larger are suitable U CMAD3 U TV1x 2 U TV0 5xC 3 U TV0 63xC GX TV0 5xC GX TV0 7xC MVX TV0 63xC MVX TV1xC Upright microscopes BX61 BX51 BX41 CX41 CX31...

Страница 13: ...the camera with a laptop Generally speaking it is possible to operate the camera with a laptop If the power supply is not sufficient to operate the camera when an integrated USB interface is used conn...

Страница 14: ...dardized software interface between software programs and image acquisition hardware such as digital cameras or scanners You can download the DP2 TWAIN software from this Olympus website https www oly...

Страница 15: ...acturer Also pay attention to the safety instructions given below After you have inserted the card make sure to note the following point This step is only necessary when a USB PCI express card is incl...

Страница 16: ...programs that run in the background for example antivirus software 2 Browse to the directory that contains the software and double click the setup exe file The installation wizard starts Follow the i...

Страница 17: ...cable with the type B plug into the camera socket Make sure that you only use the USB cable that is delivered with your camera The proper functioning of the camera can only be guaranteed when this cab...

Страница 18: ...allation only takes a few seconds Please pay attention to the icons displayed in the status bar 5 Wait until the installation of the camera driver has been finished The camera has now been registered...

Страница 19: ...an gauze moistened with pure alcohol Cleaning the housing Parts other than the glass components should be cleaned by wiping with a clean cloth Do not use organic solvents to remove major stains Use a...

Страница 20: ...tions Install or maintain imaging software Maintain imaging software Provide licenses update installation When the Image source selection dialog box is displayed select the Olympus manufacturer and se...

Страница 21: ...h the European Union directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2011 65 EU 7 4 FCC conformity USA This device complies with part 15...

Страница 22: ...eorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is...

Страница 23: ...7 Notes on conformity and disposal 23 7 6 China RoHS conformity China...

Страница 24: ...63 0914 Japan OLYMPUSEUROPASE CO KG Wendenstrasse 14 18 20097 Hamburg Germany OLYMPUSCORPORATIONOFTHEAMERICAS 3500 Corporate Parkway P O Box 610 Center Valley PA 18034 0610 U S A OLYMPUSCORPORATIONOFA...

Отзывы: