4. ASSEMBLY (
OLY-J15/3
ONLY)
1.2.3. OPERATIONAL PRECAUTIONS
The heater must only be used by people who have read these
instructions and have been trained in its use.
DO NOT
obstruct the air inlet and outlet sections of the heater.
DO NOT
cover the heater.
DO NOT
touch the heater casing or grille when first switched
off, as these will be very hot and will take time to cool.
DO NOT
get the heater wet or use in areas of high
condensation.
DO NOT
allow the power lead to touch hot surfaces.
DO NOT
connect the heater to a timer device or other
equipment than can automatically switch the heater on or off.
If an extension cable is required it must be of the same cross
section as the heater cable. It must be as short as possible
and fully unwound.
DO NOT
connect other appliances to the same mains socket as
the heater.
1.2.4. COMMON SENSE PRECAUTIONS
DO NOT
operate the heater when you are tired or under the
influence of alcohol, drugs or intoxicating medication.
DO NOT
stand on the heater.
DO NOT
use the heater with wet hands or when there is water
on the power cord.
Ensure that the heater is correctly turned off when not in use
and store in a safe, dry, childproof location.
DO NOT
use the heater for anything other than its intended
purpose. It is designed to provide heat in enclosed areas larger
than 4m³, such as workshops and other industrial areas. It is
not suitable for drying clothes or laundry.
Electric fan heaters for industrial applications.
JetHeat
Model
N
umbers:
OLY-J5/3 & OLY-J9/3
feature two heat settings and
fan only option. Model No.
OLY-J15/3
features three heat
settings and adjustable thermostat control with fan only option.
Auto cooling system to prevent unit from overheating during
use. A totally dry heat with no condensation, no gas, no fumes,
no smell. Ideal for workshops and garages. Model No.
OLY-
J5/3
&
OLY-J9/3
are
supplied with three phase power cable
and plug. Model No.
OLY-J15-3
supplied with three phase
plug (extension lead required).
Model No: . . . . .
O L Y - J 5 / 3 . . . O L Y - J 9 / 3 . . . O L Y - J 1 5 / 3
Class:
. . . . . . . . . . . . IPX4. . . . . . . . .
IPX4 . . . . . . . . .
IPX4
Max. Power:
. . . . . . . .
5000W. . . . . . . . 9000W . . . . . . .
15000W
Supply:
. . . . . . . . . 415V-16A. . . . . . 415V-16A . . . . . .
415V-32A
Heat Settings:
.
. .
. 2500/5000W. . .
4500/9000W .
. .
. 5000/10000/15000W
S
etting
Range
Thermostat:
. . . . . . .
0 - 40ºC. . . . . . . 0 - 40ºC . . . . . . . . 0 - 40ºC
Size (mm):
. .
.
. . 315x330x400.
. . .
. . 350x405x460
. .
. .
495x520x860
fig.
fig.
fig.
4.1. ASSEMBLY OF THE LEGS.
(See fig.1)
4.1.1. On either side of the heater body there are two threaded inserts
(B) for mounting the 'V' shaped leg frames (A). Note that the
axle hole at the shorter end of the 'V' frames should be
orientated towards the back of the heater.
4.1.2. Take two M8 x 40mm bolts (D) and slide a plain washer (C) onto
each one. Insert a bolt through each of the mounting holes on
the leg frame and slide a split washer (E) over each protruding
bolt. Align the bolts with the two threaded inserts (B) on the
heater body and screw them down securely.
4.1.3. Mount the other 'V' frame to the other side of the heater body in
the same way.
4.2. ASSEMBLY OF THE WHEELS.
(See fig.2)
4.2.1. Take the axle rod (F) and insert it through the holes in the 'V'
frames so that the threaded rod ends protrude equally either
side. Retain the axle rod in this position by inserting a split pin
(G) through the holes situated just on the inside of each leg
frame.
Original Language UK English
IMPORTANT!
This unit is designed to raise the ambient temperature
of an entire room, the temperature of the air coming out of the
front of the heater will be warmer than the general temperature
of the room, but there may not be a significan increase owing to
the large volume of air passing over the element. For the same
reason, the element is hot during operation, but does not glow.
The room temperature depends on room size, insulation and
ambient temperature, which will increase as the room warms.
2. INTRODUCTION
3. SPECIFICATION
Olympus OLY-JetHeat | Issue 2) 17/08/16
© Olympus Industrial Appliances UK