Olympus FLUOVIEW FV300 Скачать руководство пользователя страница 16

All brands are trademarks or registered trademarks of their respective owners.

Monitor images are simulated.

Specifications are subject to change without any obligation on the part of the manufacturer.

This catalog is printed by enviromentally-friendly 
waterless printing system with soy ink.

ISO9001

Certification

Design and production

 adheres to ISO9001

 international quality standard.

ISO14001

Design and production at the OLYMPUS 

CORPORATION Ina Plant conforms with 

ISO14001 specifications for 

environmental management systems.

Certification

008

U K A S

ENVIRONMENTAL

MANAGEMENT

Certified ISO 14001 by

FV300-IX dimensions

(unit: mm)

FV300-BX dimensions

(unit: mm)

Different types of laser combiners

Laser combiner with 
Ar+HeNe (Red) / (Green) lasers
Laser combiner with 
Multi Ar+HeNe (Red) / (Green) lasers

•Installation stand is not included in the unit.

* Please consult your Olympus dealer for additional laser
combinations.

External transmitted light detector system

Fluorescence illumination system

•Standard configuration for FV300-BX51/FV300-BX61/
FV300-BX51WI/FV300-BX61WI combination. 

LD405 laser unit

*Direct fiber connection to scan unit.

LD440 laser unit

External transmitted light detector 

and

fluorescence illumination system

Selectable from ND filter or AOTF combiner.
The shutters and light intensity can be
controlled via the Fluoview computer.
* Laser combiner for AOTF is required for
multi-line Argon laser.

This product corresponds to regulated goods as stipulated in the "Foreign Exchange and
Foreign Trade Control Law". An export license from the Japanese government is
required when exporting or leaving Japan with this product.

1310

1500

1200

1130

2330

1310

1370

1200

1130

2330

Depth: 990

Depth: 990

Printed in Japan M1444E-0205B

Содержание FLUOVIEW FV300

Страница 1: ...CONFOCAL LASER SCANNING BIOLOGICAL MICROSCOPES FV300 FLUOVIEW...

Страница 2: ...stage upright microscope platforms the FV300 offers excellent versatility as well as top class laser scanning performance Highest image quality 12 bit 2048x2048 pixel resolution with economical cost E...

Страница 3: ...r introduction w Beam collimator e Polarizer r Dichromatic mirror t Excitation dichromatic mirror y XY galvanometer mirror scanners u Pupil lens i Collector Lens o Pinhole turret 0 Emission beam split...

Страница 4: ...ine scanning Intensity changes may be measured over a given period of time along the length of a freely drawn line such as the trace of an axon or along a cellular junction Clip scanning By cropping t...

Страница 5: ...well Once optimized steps q r can be performed easily Scanning unit set up monitor display Human colon crypt Nuclei Blue TO PRO 3 Actin Green Alexa 488 APC gene product Red Alexa 568 Christine Anderso...

Страница 6: ...er glass long working distance water immersion objectives and an optional XY translation stage that moves the entire confocal microscope system while the sample and other experimental hardware remains...

Страница 7: ...low chart optional time course software TIEMPO Hardware and software support to optimize the environment for FRET FRET Input output of external trigger signal The optional time course software gives c...

Страница 8: ...by describing the individual steps or phases within the experiment Users can specify detailed conditions and parameters for each step This function enables users to construct complex experimental prot...

Страница 9: ...h point such as XYZ coordinates the Z axis acquisition range and the detector sensitivity 2 Up to 5 X 5 adjacent fields of view registered automatically Since adjacent fields of view are registered au...

Страница 10: ...on driving mechanism that enables 0 01 m step control within the BX61 BX61WI and IX81 motorized microscopes high quality continuous cross sectional images can be acquired The 3D function also provides...

Страница 11: ...hysioview software Axon PC side Working conditions Clampex Ver 8 0 or later Physiolink software FV300 side Colocalization image white Colocalization By using this function to analyze multi color speci...

Страница 12: ...g pseudo colors Mituyo Kinoshita Pr Kentaro Arikawa Laboratory of Neuroethology Graduate School of Integrated Science Yokohama City University Purkinje cell in the rat cerebellum FITC vesicular GABA t...

Страница 13: ...ish embryo Extended focus image of 10 mx28 slice Pr Yasuhiro Kamei Pr Shunsuke Yuba Institute for Molecular and Cellular Biology Osaka University GFP labeling of Drosophila adult brain with staining o...

Страница 14: ...BA625IF BA660IF BA585 640 440 LD 405 LD 458 Multi Argon 488 Multi Argon 515 Multi Argon 543 Green HeNe 568 Krypton Argon 633 Red HeNe 488 Argon SDM515 SDM505 SDM570 RDM630 SDM630 SDM560 SDM600 ECFP E...

Страница 15: ...lication Real time image calculation Kalman filtering peak integration software Hardware control Laser scanning unit microscope Each image display Single channel side by side merge cropping tiling ser...

Страница 16: ...Multi Ar HeNe Red Green lasers Installation stand is not included in the unit Please consult your Olympus dealer for additional laser combinations External transmitted light detector system Fluorescen...

Отзывы: