Expandability to Support Diverse Application.

Application

Standard Functions

Optional Functions

Molecular interaction and 

Intracellular diffusion measurement

molecular concentration 

Calculation of diffusion coefficients for intracellular molecules, and analysis of 

analysis

molecular binding and changes in molecular density. 
Supports a wide range of methods (RICS/ccRICS, point FCS/point FCCS and 
FRAP).

Software Required: Diffusion measurement package

Laser Light stimulation

Acquires images while rapidly switching 

SIM scanner system

the built-in laser between imaging and 

Performs simultaneous imaging and laser light stimulation. Provides detailed 

laser light stimulation. 

settings for laser light stimulation including position and timing. 

Features tornado scanning for high-

Features tornado scanning for high-efficiency bleaching using laser light 

efficiency bleaching using laser light 

stimulation.

stimulation.

Equipment Required: SIM scanner, laser combiner (dual fiber version)

Multi-point laser light stimulation system

Register multiple points for laser light stimulation, and program the respective 
stimulation order, stimulation time and type of stimulation (continuous laser light 
or pulse laser light).

Software Required: Multi-stimulation software

Multi-dimensional 

Long time-lapse system

time-lapse imaging

Microscopes equipped with zero drift compensation (ZDC) acquire each image at 
a set focus plane. The microscope CO

2

incubator maintains cell activity for a long 

period for continuous imaging.

Equipment Required: IX81-ZDC microscope, CO

2

incubator

Multi-point scanning system

Register multiple points for repeated image acquisition. Efficiently observe multiple 
cells in parallel on 35-mm dishes, microplates or chamber slides. 

Software and Equipment Required: 
Multi-area time-lapse software, motorized XY stage**

3D mosaic imaging

3D mosaic imaging system

Continuous imaging of adjacent fields of view and mosaic imaging to form a 

composite image.
Acquisition of adjacent Z-series images for 3D mosaic imaging.

Software and Equipment Required: 
Multipoint time-lapse software, motorized XY stage**

TIRFM TIRFM 

imaging

Uses the laser from the laser combiner to provide evanescent illumination, for 

imaging the movement of molecules near the glass surface, such as cell 
membranes and adhesion factors.

Software and Equipment Required: TIRFM unit*, TIRF objective, high-
sensitivity CCD camera**, CCD camera control software**

FRET

Provides FRET analysis functions.

CFP-YFP FRET

Diode laser offers exceptional stability 

Ratio imaging and sensitized emission. 

and long life.

Available 440 nm diode laser is optimized for CFP-YFP FRET experiments 

Supports FRET efficiency 

methods.

measurements using acceptor 

Diode laser offers exceptional stability and long life.

photobleach method. 

Equipment Required: LD 440 nm Laser

Multi-color imaging

Three-channel detector for 

Imaging blue dyes

simultaneous acquisition of 

Available 405-nm laser for image acquisition of multi-stained samples labeled with 

fluorescence images from three 

V-excitation fluorescent dyes such as DAPI, Hoechst and Alexa 405.

different dyes. 

Equipment Required: LD 405 nm laser

Sequential mode for acquisition of 

Simultaneous four-color imaging

fluorescence images without cross-talk.

Fourth channel detector can be easily added to simultaneously acquire images of 

Fluorescence can also be separated 

four colors.

using unmixing (only available on

Equipment Required: 4-channel detector

spectral scan unit).

Colocalization analysis

Easily determine if labeled substances 

High-accuracy colocalization analysis

are present locally in the same 

New 60x oil-immersion objective offers image acquisition with exceptional 

locations. 

positional accuracy coefficient.

Calculate of Pearson coefficients,  

Equipment Required: PLAPON 60xOSC

overlap coefficients and colocalization 
indices.

*  SIM scanner and TIRFM scanner cannot be installed on the same system.
** For more information about peripheral equipment, contact your Olympus dealer.

105

105

125

Pixels

Pixels

125

130

130

0

0.5

1

1.5

P1

P2

P3

P4

P5

21

Содержание Fluoview FV1000

Страница 1: ...Confocal Laser Scanning Biological Microscope FV1000 FLUOVIEW FLUOVIEW Always Evolving...

Страница 2: ...cated laser light stimulation scanner to achieve simultaneous targeted laser stimulation and imaging for real time visualization of rapid cell responses The FV1000 also measures diffusion coefficients...

Страница 3: ...2 Imaging to Analysis ing up New Worlds From Imaging to Analysis FV1000 Advanced Deeper Imaging with High Resolution FV1000MPE...

Страница 4: ...se optical advances boost the overall system capabilities and raise performance to a new level Imaging Stimulation and Measurement Advanced Analytical Methods for Quantification Now equipped to measur...

Страница 5: ...4...

Страница 6: ...with Minimum Phototox Two versions available Single fiber type combiner is used for main scanner FV1000 with up to six lasers ranging from 405 to 635 nm Dual fiber type combiner is used for laser ligh...

Страница 7: ...Tissue culture dishes slide chambers microplates and glass slides can be used with live cells and fixed specimens BX61 UIS2 Objectives Olympus UIS2 objectives offer world leading infinity corrected o...

Страница 8: ...ength detection range 495 nm 561 nm in 2 nm steps Excitation wavelength 488 nm Courtesy of Dr Shigeo Okabe Department of Anatomy and Cell Biology Tokyo Medical and Dental University EGFP EYFP Fluoresc...

Страница 9: ...and circles SIM Scanner Unit for Simultaneous Laser Light Stimulation and Imaging Branching of laser in laser combiner Lasers are used for both imaging and laser light stimulation LD405 LD635 AOTF AOT...

Страница 10: ...in in Ptk2 cells labeled with two colors 405 nm 635 nm and compared Improved Flatness and Resolution at 405 nm Better flatness reduces the number of images for tiling 450 400 0 5 0 0 Focal plane m 0 5...

Страница 11: ...ide field of view with improved transmittance at near infrared wavelengths A correction collar compensates for spherical aberration caused by differences between the refractive indices of water and sp...

Страница 12: ...al available scanning modes including ROI point and high speed bidirectional scanning Configurable Excitation Laser Power Easily adjust the optimum laser power for each specimen live cells and fixed s...

Страница 13: ...ables multiple measurement points in glass slides 35 mm dishes or individual microplate wells Repeated imaging of multiple cells improves the statistical power of time lapse experiments Mosaic Imaging...

Страница 14: ...ad Application Support and Sophisticated Experiment Control Measurement Light Stimulation Multi Dimensional Time Lapse FRET Colocalization 3D Mosaic Imaging Multi Color Imaging 3D 4D Volume Rendering...

Страница 15: ...s and proteins 3D 4D Volume Rendering One click 3D 4D image construction from acquired XYZ T images Change the angle of 3D image with a single click Colocalization Configurable threshold values for fl...

Страница 16: ...fied regions Cross correlation RICS ccRICS characterizes molecular interactions using fluorescent labeled molecules in two colors FRAP Analysis The Axelrod analytical algorithm is installed as a FRAP...

Страница 17: ...btained for each pixel was sampled at different times so the data for each pixel is affected by the passage of time in addition to its spatial XY information By analyzing this image data with a new st...

Страница 18: ...ages it is possible to characterize the diffusion speed of the molecule and the speed of binding and release between the molecule and cell structures Example Fluorescence recovery without interactions...

Страница 19: ...on Dynamics Before Stimulation After Stimulation 405 nm 405 nm Caged Glutamate Fluorescent calcium indicator Fluo 3 in HeLa cells Image acquisition at 1 second intervals Using the caged compound Bhcmo...

Страница 20: ...the environment inside the tissue culture dish completely stable The environment is precisely maintained at 37 C with 90 humidity and 5 CO2 concentration ZDC Baseline focal plane IR Laser for focal pl...

Страница 21: ...asily register wide areas and the thumbnail display provides a view of the entire image acquired during the mosaic imaging process Coordinate Information Thumbnail CNS markers in normal mice Objective...

Страница 22: ...ic imaging to form a composite image Acquisition of adjacent Z series images for 3D mosaic imaging Software and Equipment Required Multipoint time lapse software motorized XY stage TIRFM TIRFM imaging...

Страница 23: ...dability 350 350 300 300 400 400 450 450 500 500 550 550 600 600 650 650 700 700 750 750 800 800 405 LD 440 LD 473 LD 635 LD 559 LD 458 M ulti Argon 515 M ulti Argon 543 G reen H eN e 488 Argon mCherr...

Страница 24: ...light path ensures that expandability of the microscope itself is not limited Visible UV and IR laser introduction ports are provided as well as a feedback control system Illumination Units Convention...

Страница 25: ...CO2 incubator Motorized XY stage Scanning unit for IX81 Spectral type or Filter type detector system 559 nm 458 488 515 nm 405 nm A B D E F E F G D B E A F G A B D G C FV1000 System Diagram IX81 ZDC...

Страница 26: ...line with free orientation free line Point scanning Line scanning Straight line with free orientation free line Point scanning Photo Detection Method 2 detection modes Analog integration and hybrid ph...

Страница 27: ...ciences Cerebellum Purkinje cell Courtesy of Dr Tetsuro Kashiwabara Assistant Professor and Dr Akira Mizoguchi Professor Neuroregenerative medicine course Mie University School of Medicine Drosophila...

Страница 28: ...isit our web site for details Windows is a registered trademark of Microsoft Corporation in the United States and other countries All other company and product names are registered trademarks and or t...

Отзывы: