Страница 1: ...o ensure the safety obtain optimum performance and to familiarize yourself fully with the use of this microscope we recommend that you study this manual thoroughly before operating the microscope Reta...

Страница 2: ...limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio freque...

Страница 3: ...usting the Contrast 12 5 USING THE CONTROLS 5 1 Base 13 15 1 Adjusting the Brightness 13 2 Setting the LIM Brightness 13 3 Using the Filters Halogen Bulb Operation Only 14 5 2 Focusing Block 16 17 1 F...

Страница 4: ...PROPER SELECTION OF THE POWER SUPPLY CORD 39 40 7 TROUBLESHOOTING GUIDE 8 SPECIFICATIONS 9 OPTICAL CHARACTERISTICS UIS2 Series 10 ASSEMBLY See this section for the replacement of the light bulb 11 HAL...

Страница 5: ...e warranted 5 Always ensure that the grounding terminal of the microscope and that of the wall outlet are properly connected If the equipment is not grounded Olympus can no longer warrant the electric...

Страница 6: ...t or other inquiry 1 Getting Ready 1 A microscope is a precision instrument Handle it with care and avoid subjecting it to sudden or severe impact Also note that the microscope does not have a waterpr...

Страница 7: ...4 After using the microscope set the main switch to OFF wait for the lamp socket to cool down sufficiently if the halogen bulb has been used and keep it covered with a dust cover during storage 5 Bef...

Страница 8: ...onsult Olympus For the products marked also read their instruction manuals Eyepieces WHN10X WHN10X H Revolving nosepiece BX43 5RES U 5RE 2 U D6RE Stage U SVRB 4 U SVRO Observation tube U BI30 2 U TBI...

Страница 9: ...ent ring Page 22 Slide holder clamping lever Page 19 Aperture iris diaphragm ring Page 12 Condenser centering screws Page 12 Filter mount Page 15 Field iris diaphragm ring Page 12 Condenser height adj...

Страница 10: ...ch Page 10 I ON OFF Fine adjustment knob Page 16 Pre focusing lever Page 16 LIM indicator ON Lit Green OFF Extinguished LIM ON OFF switch Page 13 LED brightness adjustment knob Page 13 LIM setting swi...

Страница 11: ...3 Auxiliary lens The auxiliary lens is mounted on the lamp adapter when the U LC is used Page 34 Top lens swing out knob Top lens Aperture iris diaphragm ring Page 12 Condenser mount dovetail Modules...

Страница 12: ...ecimen in focus 9Coarse fine adjustment knobs P 17 Adjust the interpupillary distance Adjust the diopter Adjust the light axis aBinocular tube P 21 bDiopter adjustment ring P 21 cCondenser height adju...

Страница 13: ...9 BX43 Copy the observation procedure pages on separate sheets and post it near your microscope 9 a 5 trinocular tube only d c e 2 f 3 7 1 4 b 8 6 g...

Страница 14: ...For the detailed operating procedure of each control please read the description page specified below Press the main switch of the microscope frame to I ON Rotate the knob to adjust the lamp brightne...

Страница 15: ...pillary Distance While looking through the eyepieces adjust for binocular vision until the left and right fields of view coincide completely Note your interpupillary distance so that it can be quickly...

Страница 16: ...he field of view slightly D in Fig 9 1 2 3 4 5 6 7 8 9 1 2 Be careful not to rotate the condenser clamping screw located behind the centering knobs by mistake When using a condenser with top lens such...

Страница 17: ...ness for the objectives is set selecting an objective adjusts the LED brightness automatically provided that the LIM ON OFF switch is set to ON which is indicated by the lighting of the LIM indicator...

Страница 18: ...on the base and engage in the light path Page 14 Insert a filter in the U FC filter cassette attach it on the filter mount and engage it in the light path by sliding the filter level Page 14 Mounting...

Страница 19: ...ference type filter is used flare and ghost may be observed These phenomena may be reduced by adding ND filter s to the IF filter The LBD filter is not required when the LED lamp is used What is LBD f...

Страница 20: ...This knob can be attached to the fine adjustment dial on either the left or right side When the microscope is shipped it is attached to the right side dial 4 Pre focusing lever Sets the upper limit of...

Страница 21: ...using the tension adjustment ring Turning the ring in the direction of the arrow increases tension and vice versa The tension is too low if the stage drops by itself of focus is quickly lost after adj...

Страница 22: ...listed below that cause less interference with the objectives U HRD 4 U HLD 4 U HLS 4 The applicable objectives are ones with 40X or less magnification except Apo series Using an Oil Immersion Condens...

Страница 23: ...w Treatment Horizontal direction Hold the specimen holder and move the stage guide to the left and right so that it hits the stoppers Vertical direction Hold the upper stage and move it to the front a...

Страница 24: ...ring the position of the substage the microscope will accommo date specimens with maximum height of 35 mm This is useful when observing metallurgical specimens and other thick objects 1 Lower the stag...

Страница 25: ...n the light path rotate the right diopter adjustment ring to bring the specimen into focus Do not touch the coarse and fine adjustment knobs during the focusing 4 Looking into the left eyepiece with y...

Страница 26: ...tain micrometer disks In this case turn the frame slowly but with a stronger force than usual 4 Selecting the Light Path of the Trinocular Tube Slide the light path selector knob to select the desired...

Страница 27: ...al field capable of the adjustments of the positioning angle 0 to 25 as well as front rear positioning by 45 mm of the eyepieces The U ETBI is the erect image model and the U TTBI is the inverted imag...

Страница 28: ...ification Condenser Low magnification U LC Abbe U AC2 Achromat aplanat U AAC Swing out U SC3 Ultralow magnification U ULC 2 1 25X Applicable FN 22 Applicable FN 26 5 2X Applicable FN 22 Applicable FN...

Страница 29: ...ass and the top surface of the condenser When oil is not present the NA is about 0 9 4 After use remove immersion oil from the objective front lens by wiping with gauze slightly moistened with absolut...

Страница 30: ...ils refer to the instruction manuals for these accessories 1 System Chart TV camera digital camera Camera mount adapter Camera adapter C mount camera adapter Trinocular observation tube U TR30 2 U SWT...

Страница 31: ...22 Common Condenser is not properly centered Center the condenser 12 Common Condenser height is too low Adjust correctly 24 Halogen ND filter is engaged Disengage the ND filters 15 Brightness cannot b...

Страница 32: ...mersion oil is not used Use an Olympus designated immersion oil 25 Common Dirt dust on specimen Clean it 3 Common Dirt dust on condenser top lens One side of image is blurred Common Objective is not c...

Страница 33: ...n Diopter adjustment is incorrect Adjust diopter 21 Common Different eyepieces are used on left and right Change one eyepiece to match the other so that both sides are the same type 32 Common Your vie...

Страница 34: ...nosepiece Attachable module Transmitted light DIC slider Transmitted light analyzer 5 Observation tube Type U BI30 2 U TBI 3 U TBI3 CLI U TR30 2 U SWTR 3 Widefield binocular Widefield tilting binocula...

Страница 35: ...per widefield FN 26 5 8 Operating environment Indoor use Altitude Max 2000 meters Ambient temperature 5 to 40 C 41 to 104 F Maximum relative humidity 80 for temperatures up to 31 C 88 F decreasing lin...

Страница 36: ...pochromat FN 26 5 PH Phase contrast UPlanFLN Ph 4X Ph 10X2 Ph 20X Ph 40X Ph 40XO 60X 60XOI Ph 100XO2 Ph 100XOI2 0 13 0 3 0 5 0 75 1 3 0 9 0 65 1 25 1 30 0 6 1 30 17 0 10 0 2 1 0 51 0 2 0 2 0 12 0 2 0...

Страница 37: ...ng the internal screws to ensure the performance we recommend that you have your Olympus representative assemble or remove this module Eyepieces WHN10X FN 22 WHN10X H FN 22 SWH10X H FN 26 5 MICRO SWH1...

Страница 38: ...mp housing into the mount hole on the rear of the microscope by aligning the clamping screw 2 and screw hole 3 2 Using the Allen screwdriver tighten the clamping screw 2 3 Insert the connector of the...

Страница 39: ...straight and fully into the pin holes on the lamp socket To prevent reduced bulb life or cracking do not touch the bulb with bare hands If fingerprints are accidentally left on the bulb wipe the bulb...

Страница 40: ...and gently raise the condenser holder to its highest position 10 Attaching the Eyepieces Fig 51 Gently insert the eyepieces all the way into the eyepiece sleeves When using the U BI30 2 binocular tube...

Страница 41: ...ion Using the AC Adapter Fig 53 1 Insert the connector of the power cord firmly into the input connector 2 of the AC adapter Fig 53 The power cord should be connected to a grounded earthed 3 conductor...

Страница 42: ...ve any questions please contact Olympus Check results Date Check items 1 More than 8 years have passed since original purchase or the total power ON time exceeds 20 000 hours 2 Lamp does not light som...

Страница 43: ...ng Table 1 Certified Cord A power supply cord should be certified by one of the agencies listed in Table 1 or comprised of cordage marked with an agency marking per Table 1 or marked per Table 2 The f...

Страница 44: ...Cables BASEC BASEC HAR 10 10 30 N V KEMA KEMA KEUR HAR 10 30 30 SEMKO AB Svenska Elektriska Materielkontrollanstalter SEMKO HAR 10 10 50 sterreichischer Verband f r Elektrotechnik VE VE HAR 30 10 50...