background image

BondMaster 600 — Getting Started Guide

7

Keypad

The BondMaster 600 is available with an English, International, Chinese, or Japanese keypad 
configuration.

English

International

Function

Enter

The Enter key is used to make selections.

Return

The Return (or, Back) key is used to exit a menu and 
return to a previous screen.

CAL/NULL

If this direct function key is pressed once, it nulls 
(zeros) the BondMaster 600. If this key is pressed and 
held, a calibration wizard is initiated in RESON 
(resonance) and MIA (mechanical impedance 
analysis) modes of operation only.

GAIN

Direct function key used to display either the 
BondMaster 600 combined horizontal and vertical 
gain settings, horizontal gain only, or vertical gain 
only.

English keypad

International keypad

Chinese keypad

Japanese keypad

Содержание BondMaster 600

Страница 1: ...n imminently hazardous situation and calls attention to a procedure practice or the like which if not correctly performed or adhered to will result in death or serious personal injury Indicates a pote...

Страница 2: ...51431 8 cell battery holder with connector plug Olympus P N 600 BAT AA U8780295 Pitch and catch and MIA mode cable for BondMaster 600 3 3 meter 11 foot length 11 pin to 11 pin connectors Olympus P N S...

Страница 3: ...ding alkaline batteries in the battery holder P N 600 BAT AA U8780295 or use any other charger adaptor Doing so might cause an explosion or injury Do not attempt to power or charge other electronic eq...

Страница 4: ...thumb screws to complete the installation To Install the MicroSD Card 1 Remove the MicroSD card P N MICROSD ADP 2GB U8779307 from its packaging 2 Loosen the two thumb screws and then open the BondMas...

Страница 5: ...on Menu Navigating the application menu is designed to be intuitive and the settings for each application are designed to permit immediate inspection little or no additional instrument setup is needed...

Страница 6: ...aximum of two real time readings from among the available choices You can set the real time readings bar to display one or two readings or you can deactivate it The instrument settings are displayed o...

Страница 7: ...eturn to a previous screen CAL NULL If this direct function key is pressed once it nulls zeros the BondMaster 600 If this key is pressed and held a calibration wizard is initiated in RESON resonance a...

Страница 8: ...isplay MAIN Provides access to the main menu which controls functions such as frequency gain angle filters RF signal and gate DISP DOTS Provides access to the display menu which controls functions suc...

Страница 9: ...cell contents which are corrosive and explosive Do not short circuit the battery terminals A short circuit could cause injury and severe damage to a battery making it unusable Do not expose a battery...

Страница 10: ...Fischer connector Up to 80 V can be present on the inner conductors The warning symbol shown in the figure below warns of this electric shock risk The instrument must only be connected to a power sour...

Страница 11: ...BondMaster 600 Getting Started Guide 11...

Страница 12: ...Copyright 2014 by Olympus All rights reserved All brands are trademarks or registered trademarks of their respective owners and third party entities Part ID U8030413 U8030413 Printed on Rolland Hitec...

Отзывы: