Cooling Unit
Hot Station Temperature °C
Cold Station Temperature °C
5
10
15
20
25
30
0
SEC
Timer
5
10
15
20
25
30
0
SEC
Timer
Head Lock
VC-19D
Cooling Unit
M A D E I N G R E E C E
2. Cold Station Temperature
: Set the temperature from 9 to
11°C (find the suitable temperature for the minimum
condensation).
4. Head Lock:
Heads’ lock ON/OFF.
6. Cold station Time:
Set the timer from 5 to 30 sec. Less
time at cold station will result in a more shallow angle.
Panel Adjustments
1
3
5
4
6
2
Panel Adjustments
1
Hot Station Temperature
: Set the temperature from 60 to
110°C. Temperature is a basic factor for the crimping.
Choose the higher temperature (according the material you
use) for higher crimping result. (Suggested Temperature
110°C).
To adjust thermoregulator press the DOWN arrow. When
the digits start blinking use the UP and DOWN arrows to
adjust the temperature.
Then you press instantly the button.
3. Hot station
Set the timer from 5 to 30 sec. By
Time
:
increasing the time a higher crimping is succeeded.
5.
Cooling unit ON/OFF.
VC-19D Operator’s manual