4.5 Plumb in steering hydraulic system using a good grade of pipe tube suitable for a
1750 PSI system. Ensure system is well flushed and clean before filling with
hydraulic oil.
Note:
Refer to attached piping drawing (B-0318A)
4.6 Fill steering system with ISO 32 Hydraulic oil
4.7 When running system for the first time after filling with new oil, check the
reservoir tank oil level and top it up until all air has been bled out of system.
Note:
The hydraulic pressure relief settings of the Vickers hydraulic
pumps supplied by Olympic Drives are as follows:
HD3 Olympic Drive (V20F
pump) …….1750 PSI
SD1 & UD2 Drives (V10F
pump) …….1200 PSI
5.0 Steering Hydraulics, Power Unit
5.1 Mount hydraulic power unit in an easily accessible protected location near the
Olympic Drive. Ensure there is adequate air circulation for cooling of the oil
reservoir. Max operating Steering Oil temp 160° F (71° C).
5.2 Plumb in steering hydraulic system using a good grade of pipe tube suitable for a
2500 PSI system. Ensure system is well flushed and clean before filling with
hydraulic oil.
Note:
Refer to attached hydraulic schematic
5.4 Fill steering system with ISO 32 Hydraulic oil.
5.5 Mount the motor starter panel near the power unit. Connect the motor starter to
the power unit following the attached motor starter instructions (A308614-01).
5.6 Connect temperature and low-level alarm to motor starter and alarm system.
5.6 When running system for the first time after filling with new oil, check the
reservoir tank oil level and top it up until all air has been bled out of system.
Note:
Содержание HD3
Страница 7: ...Olympic Drives Equipment Sales Ltd 7 HD3_Mounting_Dimensions_D 0071A_Model ...
Страница 8: ...Olympic Drives Equipment Sales Ltd 8 Olympic_Mounting_Ring_B 0441_Layout ...
Страница 9: ...Olympic Drives Equipment Sales Ltd 9 Olympic Drive Installation Drawing B 0440 ...
Страница 10: ...Olympic Drives Equipment Sales Ltd 10 HD3 Piping Drawing ...
Страница 11: ...Olympic Drives Equipment Sales Ltd 11 SD1 Piping Drawing ...
Страница 12: ...Olympic Drives Equipment Sales Ltd 12 HD3 Mounting Dimensions ...