background image

Thank you for purchasing this quality product. Olympia products are rigorously tested to provide long service 

under normal conditions. Prior to installation, familiarize yourself with this parts diagram. Make sure that you have 

all of the illustrated parts for your Olympia product before installation.

ITEM #

DESCRIPTION

A

OP-190014C,H

ADA Wrist Blade Handle Cold, Hot

B

OP-490040

Bonnet Nut

C

OP-390004

Cartridge–Brass Post

D

OP-490041

Springs and Seats

E

OP-450011

Deck Plate

F

OP-450012

Base Gasket

G

OP-590003

Mounting Locknut & Washer

H

OP-590001

Supply Nut

I

OP-250004

Gooseneck Spout (B-8170 Spout)

I1

OP-250005

Gooseneck Spout (B-8180 Spout)

I2

OP-250007

Hi-Rise Spout (B-8190 Spout)

1

OP-450013

Handle Screw

2

OP-490001C,H

Cold & Hot Indicator

3

OP-490035

1.5 GPM Aerator

4

OP-450010

Spout Bonnet Nut

5

OP-490038

Spout Snap Ring

6

OP-490039

Spout O-ring

7

OP-450014

Hose Thread Adapter

INSTALLATION INSTRUCTIONS

Tools you will need:

Plumbers Putty

• 

Teflon Tape

• 

Screwdriver

• 

Flexible Supply Lines

• 

Pipe Wrench

• 

Adjustable Wrench

• 

Basin Wrench

• 

Soft Cloth

• 

FAUCET INSTALLATION:

Carefully shut off both hot and cold water supplies from under the sink. Plug the sink drain with 

1. 

a soft cloth to prevent intrusion of debris or the loss of any faucet parts. If this installation is for a 

replacement, carefully remove the existing faucet and clean the entire surface of the sink mounting 

holes.
Apply adequate plumbers putty along the boundary of the bottom of the base gasket (F).

2. 

Gently align the faucet with the sink mounting holes and place the faucet on the sink. Use caution to 

3. 

lead brass waterways through the sink mounting holes.
Thread friction washers and mounting locknuts (G) alone the brass waterways. Carefully hand 

4. 

tighten the mounting locknuts. CAUTION: Do not overtighten.

Connect supply lines to hot (LEFT INLET) and cold (RIGHT INLET) waterways. Use with Teflon tape 

5. 

when attaching supply lines to waterways.
Turn on the hot and cold water. Check all around for any leaks.

6. 

Remove aerator (3) from end of spout. Flush both water lines by allowing water to run through for 

7. 

one minute. Replace aerator (3). 

CAUTION:  MAKE SURE TO TIGHTEN THE AERATOR SECURELY AFTER FLUSHING THE WATER 

LINES. 

Olympia Faucets, Inc. © 2009

For more care information or trouble shooting inquiries 

about your Olympia product, please call: 

OLYMPIA FAUCETS, INC. 

(888) 772-7701 

Central Standard Time: 8:00am ~ 7:00pm

www.olympiafaucets.com

Отзывы: