922044006_09_024

be performed, the mains power supply 

Indication LED status (with connected 

and the battery should be connected (the 

mains power supply).

battery should be charged). If the battery 
is not charged, the test is postponed until 

Charge 

the battery is  completely charged. If 

On: 

Charge current OK.

during the Automatic Autonomous Test the 

Οff: 

No battery (No charging current or 

luminaire’s duration is lower than the 

disconnected battery).

named, then the battery must be 

Lamp Fault

replaced. 

Οn:

 Faulty LED strip.

Off: 

LED strip OK.

Back Up Operation

The autonomous duration of battery 

Battery Fault 

during emergency mode is at least the 

Οff: 

Battery OK. 

one that is stated in the list of the first 

Blink 

(With 

Charge LED

 ON): Autonomy 

page. During emergency mode, a LED 

or low battery problem 

(the battery must 

strip test is also performed.

be replaced).
Blink
 

(With 

Charge LED

 Off):                         

Resetting Errors

No charging current or disconnected 

Push the Test button for 5 seconds, to 

battery.

delete all the indicated LED errors. Then 
the luminaire enters regular operation 
mode.

INSTALLATION INSTRUCTIONS

General

:

1. Operations for installation, maintainance or testing must be done by authorized 
personnel only.
2. The device must be connected to the mains power supply through a fuse dependent 
by the total amount of the line’s  power load.

In case of battery or light source replacement, these must be replaced by parts of the 

same type, by the manufacturer or by a competent person.
4

t i

 in battery recycling points.

Do not incinerate.

3. 

. In case of inactive use for a period greater than 2 months, disconnect the battery by 

pulling out the battery’s connector. 
5. 

I s not allowed to discard batteries in to common trash bins, they must be 

discarded only 

1

4

3

Remove the front plastic cover by unscrewing the two 
retaining screws.
Pass the mains cables through the hole of the plastic base.
Connect the live and the neutral wires to the terminal block
as shown in picture.
Mount the device by installing the included mounting
accessories in the holes or use the Α-3018 mounting
springs for suspended seiling mounting.
Install LED strip and batery connectors to the appropriate 
PCB connectors.
Refit the front plastic cover by srewing the two 
removed screws in step 1, and power on the device.

1

2
3

4

5

6

5

2

L

N

NOTE!! 
After finishing the installation you must power the device 
at least for 24 hours for battery charging to perform 
the nominal autonomy. 