A
B
A
1
1
1
1
Luminaire
Set of Pictograms
Mounting accessories
Manual
1
2
Pictogram Installation
3
Mounting Methods
2
2
1
1
These devices are used indoors and outdoors
o
(ta 40 C) in places where emergency light is needed.
Each device must be permanently connected to
mains power supply. In normal operation the battery
is charging. The light source can be either on or off,
depending on user’s choice. In case of a mains power
supply failure, the device enters emergency mode
and the illumination LED turns on. When the mains
power supply is restored the device turns to normal
operation.
Autonomy Duration Selection
The user can select one of the 3 available minimum
autonomy durations 1 hour, 3 hours and 8 hours. The
selection must be done while the luminaire is
disconnected from AC and battery supplies. The
selection is achieved through Switches 2 & 3 of DS1
as shown below.
Technical Label Installation
Two additional labels are included in the package.
one for 3 hours duration (180) and one for 8 hour
duration (480). Depending on the selected duration,
the installer must cover the default 1 hour (60)
printing with one label that has the required
duration. Please take notice of the orientation of the
label.
Manual Operational Test
Remove the diffusor and then by pressing the test
button briefly an operation test is initiated. The light
source and the emergency circuit of the device are
tested. The manual test can be conducted only if the
mains power supply and the battery are connected.
During this test period the LAMP TEST LED will blink.
The battery must have adequate charge. This test
lasts for 3 seconds.
Manual Autonomy Test
A duration test can be conducted by pushing the button
steadily for 5 to 10 seconds. In order to be performed,
the mains power supply should be connected and the
battery should be fully charged. The luminaire enters
emergency mode, the CHARGE LED is turned OFF and
the BATTERY FAULT LED starts blinking. Its duration is
the stated autonomy duration of the luminaire. If at the
end of the test the autonomy is lower than the nominal,
the BATTERY FAULT LED will lit and battery needs to be
replaced. If the result of the test is good then the
luminaire enters charging mode and the CHARGE LED
starts blinking until the battery is fully charged.
Automatic Operational Test
This test includes all the operations that are provided
in Manual Operational Test and is conducted
automatically every 15 days and lasts 3 seconds.
Automatic Autonomy Test
The Automatic Autonomy Test is conducted every 6
months and measures the device’s back up operation
and emergency duration. This test includes all
functions of the Manual Autonomy Test.
Wireless communication
The WL luminaire models have the ability to
communicate over the air with Olympia’s control
panels for wireless emergency luminaires. The
luminaires can also communicate with a PC/laptop
through a gateway (Ethernet, Wi-Fi, USB). For more
information, please refer to Wireless Emergency
Lighting guides, available on the company’s website.
Lens Removal
When the luminaire is used without the pictograms or
the SP-1100 and you require more light output then
remove the lens that covers the LEDs.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or testing
must be done by authorized personnel only.
2. Always use in any case round mains cable, with a
diameter of 5-10mm (H05RN-F type 2x1mm² or
any other type, at least equal to it’s mechanical
and electrical properties). ATTENTION!! The cable
must not be deformed in any way (This
requirement is important to ensure the ΙΡ rating).
3. The device must be connected to the mains power
supply through a circuit breaker that is depends
on the total line’s power load.
4. In case of battery replacement, it must be replaced
by the same type, by the manufacturer or a
competent person.
5. In case of inactive use for a period greater than 2
months, disconnect the battery by pulling out the
battery’s connector.
6.
I s not allowed to discard batteries into common
t i
trash bins, they must be discarded only
in
battery recycling points. Do not incinerate.
Oly luminaires can be surface mounted on walls or ceilings. For these mounted installations, special
accessories are included.
2. Refit the diffusor with the pictogram.
1. Fit the pictogram you need to the diffuser, be careful to
secure it on the 3 plastic holders.
Wall
bottom
view
Wall installation
Ceiling installation
Ceiling
* ATTENTION!!! The below mounting methods can be done after request of the necessary
mounting accessories!!
Extra Mounting Methods *
Suspended ceiling installation
with mounting accessory
A-3018
Suspended installation with A-3018 accessory
The luminary can be installed in a suspended
ceiling.
A marking panel (
SP-1100
) can be installed on the luminary pointing the desired direction.
Suspended ceiling installation
with mounting accessories
and marking panel
Ceiling installation
with marking panel
General
5
6
7
7
8
8
9
NOTE!!
After finishing the installation you must power the luminaire for at least 24 hours in order to
completely charge the battery. The rated autonomy duration can be achieved after that time.
Package Contents
2
923100402_09_001
923100402_09_001
923100402_09_001
3
4
1h
(default position)
3h
8h
Battery Connection
Attention!!
The 6 plastic
latches (A) must be secured
(click
sound).
This
requirement is important to
ensure the IP65 rating.
Power on the luminary.
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
6) Autonomy Duration Selection
(Read on General Informations, Page 1)
7 a) Pernament Maintained Operation
7 b) Non-Maintained Operation
7 c) Controlled Maintained Operation of the lamp
ON
1 2 3 4
11
10
WARNING!!
Isolate the mains power supply before making the connections.
Ν
for neutral,
L
for live wire
Ν
for neutral,
L
for live wire
WARNING!!
Isolate the mains power supply before making the connections.
Description
Indications LED Status
BATT.
FAULT
(yellow)
LAMP
FAULT
(red)
CHARGE
(green)
Fully charged
Charging
Battery fault or
emergency mode
Operational test
Light source fault
Autonomy test
Duration fault
Note:
Permanently
ON
Blink
Indifferent
Off
N
L
Link
N
L
1
Installation Instructions
or
Switch number 4 of DS1
must be in ON position.
ON
1 2 3 4
Switch number 4 of DS1
must be in OFF position.
and
ON
1 2 3 4
Switch number 4 of DS1
must be in OFF position.
and
N
L
External
switch
1
2
3
4
5
Drill one of the 5 available holes with a 16-18mm drill bit. Install the included rubber gasket and pass
through the power cables. Install the included tie (if needed) to fasten and securely the power cables.
1
2