olympia electronics CLASSIC LIGHT Series Скачать руководство пользователя страница 2

923119004_09_004

1

Lock - unlock hook

3

Installation instructions

Οn:

                           faulty LED strip.

Off:

                           Good LED strip.

Fault 
Οff:

                                 Battery OK. 

Blink

  (With 

AC  Charge  LED

  ON): Autonomy  or 

low battery problem

(the battery must be replaced).
Blink 

(With 

AC Charge LED

 Off): 

No charging current or disconnected battery.

ΑΤΤΕΝΤΙΟΝ!!!

1.  Operations  for  installation,  maintainance  or 
testing  must  be  done  by  authorized  personel 
only.
2.  The  device  must  be  connected  to  the  mains 
power supply thru a fuse dependent by the total 
amount of the line’s  power load.

3. 

4.  In  case  of  inactive  use  for  a  period  greater 
than  2  months,  disconnect  the  battery  by  pulling 
out the battery’s connector. 

5. 

I

s  not  allowed  to  discard  batteries  in  to 

c o m m o n   t r a s h   b i n s ,   t h e y   m u s t   b e  
discarded  only 

In  case  of  battery  or  lamp  replacement,  these 

must  be  replaced  by  parts  of  the  same  type,  by 
the manufacturer or by a competent person.

t  i

  in  battery  recycling 

points. Do not incinerate.

NOTE: 

LED= Light Emitting Diode

LABELING EXPLANATION:
X: Self contained
1: Maintained
A: Including test device
*90: 90min duration 

 1  Detach the plastic base (located in the bottom of the luminaire)
     by pulling the unlock hook and pass the cables from area     or
         and through the cable entry hole. Secure it with a suitable
     bracket to ensure immobilization of the cable at a distance of
     no more than 5cm from the luminaire’s cable entry. Mount the
     plastic base  with the included mounting accessories.
 2 Connect the cables to the terminal blocks as showed in figure. 
     AC1 for L, AC2 for Ν and L1 for the maintained operation.  
     The L1 wire can be connected to an external switch to control
     the maintained or non maintained operation of the luminaire. 
     For permanent maintained operation use two wires to power
     the luminaire, AC1 for L, AC2 for Ν and link the L and L1.
 3  Attach the luminaire by sliding it on the plastic base until the
     plastic hook locks, and power the luminaire. 

AC1

AC1

AC2

AC2

External 

switch

Link

Controled operation of the luminaire

Permanent maintained operation 

N

L
L1

N

L
L1

Page 2 from 2

A

B

Plastic base

2

N

L

A

B

AC1

AC2

L

1

Cable entry hole

Cable

support

Battery replacement 
It can be done only by a competent person and after the mains interruption.

1. Detach the lamp from its base ( step 1 of the installation procedure ) .
2. Use a flat blade screwdriver to remove the diffusor.
3. Remove the reflector.
4. Disconnect the connector and remove the old battery.
5. Connect the new battery with the same type and place it in
    the position of the old one.
6. Replace the  removed parts (steps 1,2 and 3).

2