1
1
1
Dimensional drawing (mm)
Installation Instructions
1
3
4
5
2
6
6
1
2
3
127
80
56
17
137
82
Sounder
Package Contents
Adjusting the sounder & beacon
Mounting Accessories
General
Manual
This device is used as an indication of a fire panel that provides a warning audio signal
from the siren and visual indication using the beacon. The loudness and the luminous
signal it produces covers an area of several square meters. It is compatible with any
conventional panel.
Table 1
Table 2
Sound level No
Switch setting [6-7]
1
2
3
4
0-0
1-0
0-1
1-1
Switch setting [
8]
170 ms pulse at 1 Hz
170 ms pulse at 0.5 Hz
0
1
Light temporal pattern and frequency
Table 3
Table 4
Ν2
Α/Α
1
2
3
4
5
6
7
8
9
10
11
0-0-0-0-0
1-0-0-0-0
0-1-0-0-0
1-1-0-0-0
0-0-1-0-0
1-0-1-0-0
0-1-1-0-0
1-1-1-0-0
0-0-0-1-0
1-0-0-1-0
0-1-0-1-0
Pattern
match with
Table 1
No
1
1
1
1
1
11
7
8
1
1
1
Switch
setting
[1-2-3-4-5]
12
13
14
15
16
17
18
19
20
21
22
1-1-0-1-0
0-0-1-1-0
1-0-1-1-0
0-1-1-1-0
1-1-1-1-0
0-0-0-0-1
1-0-0-0-1
0-1-0-0-1
1-1-0-0-1
0-0-1-0-1
1-0-1-0-1
Ν2
Α/Α
11
11
11
1
1
17
18
19
20
21
1
Pattern
match with
Table 1
No
Switch
setting
[1-2-3-4-5]
23
24
25
26
27
28
29
30
31
32
0-1-1-0-1
1-1-1-0-1
0-0-0-1-1
1-0-0-1-1
0-1-0-1-1
1-1-0-1-1
0-0-1-1-1
1-0-1-1-1
0-1-1-1-1
1-1-1-1-1
Ν2
Α/Α
25
26
1
11
1
1
1
1
11
2
Pattern
match with
Table 1
No
Switch
setting
[1-2-3-4-5]
Angle of measurement
dB(A)
at 1m at Sound level 4
15
45
75
135
105
165
93
99
103
103
94
101
Remove the front plastic cover.
Drill the holes needed to pass the connection cables. Place the cable rubber grommets and open a hole
to the center with a small screwdriver. Pass the connection cables through the rubber grommets.
Use the supplied mounting accessories to place the base of the siren in height up to 2.4 meters from
the gound.
CAUTION!! Make sure that the base of the siren is installed in the correct orientation.
Replace the plastic cover and fasten it with the
four including screws.
NOTE!!!
After finishing the installation,
place the sticker SEAL as shown in the picture
above.
Remove the second plastic from its base.
Replace the plastic cover and fasten it with the
including red screw.
x
VAD
Cover Area
Ο
-x-y-z
Wall Mounting
y
z
x=2.4m
y=
2
.
4
m
z=
4
.
8
m
Connect supply either to N1 or N2 and the 0V.
Depending on the connection the siren will
sound with the matching pattern.
AL2
AL1
+
-
+
-
8,2k
Ω
KL6
KL5
8,2k
Ω
Seal
Visual indication of the siren
with power LED.
Supply terminals.
DIP switches for
siren and beacon settings.
Ν1
Ν2
-
1 2 3 4 5 6 7 8
ON
Ÿ
To
adjust the type of the sound indication
use DIP
switches 1 to 5, according to Table 4 and Table 5.
Depending on the input from which the device is
powered.
Ÿ
To
adjust the sound level
use DIP switches 6 to 7,
according to Table 1.
Ÿ
To
adjust the frequency of the flashing LED
use DIP
switch 8 according to Table 2.
Note:
The siren can be supplied from the input N1 or N2. In case it is supplied from both inputs
then N1 has priority. Depending on the connection you will choose and the setting of DIP
switches 1 to 5 the corresponding pattern will sound. By connecting the siren to input N1 and
configuring DIP switches 1 to 5 the pattern that will sound is shown in Table 5. By connecting
the siren to input N2 and configuring DIP switches 1 to 5 the pattern that will sound is shown in
Table 4. The difference in the patterns between N1 and N2 allows the device to be used both as
a pre-alarm and alarm indication.
Test the operation of the device through the panel after the installation.
UID: In every device there is a double sticker with the UID (Unique Identifier) number.
This number is unique for each device.
Example connection diagram with BS-1638
fire detection panel of Olympia Electronics
921532001_09_004
921532001_09_004
921532001_09_004
Rubber sealing ring
Wall Plug
Washer
Screw
Rubber grommet