Connecting a BS-413 siren to the BS-458 panel

Remove this

cable after the installation

has finished

BS-458

N

L

P2

P1

Z1

Z2

Z3

Z4

AS

TAMPER

-12V

-

-

-

-

+12V

Siren

 

BS-4

13

+

+

ST SE

T1 T2

FL

5K6

921413000_09_008

Page 4 from

 

4

WARRANTY

Olympia Electronics guarantees the quality, condition and operation of the goods. The period of 
warranty is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, 
which accompanies each product. This warranty ceases to exist if the buyer does not follow the 
technical instructions included in official documents given by Olympia Electronics or if the buyer 
modifies the goods provided or has any repairs or re-setting done by a third party, unless Olympia 
Electronics has fully agreed to them in writing. 

Products that have been damaged can be returned to 

the premises of our company for repair or replacement, as long as the warranty period is valid.

Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge 
the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or 
not the buyer the transportation cost.

HEAD OFFICE

72

nd

 

km

O

.

N

.

R

Thessaloniki-Katerini

P

.

C

. 60061 

Greece

www.olympia-electronics.gr
[email protected]

Содержание BS-413

Страница 1: ...en the siren produces a single tone sound every 1 Mounting second It is mounted externally on a flat surface and at Whereas if the battery does not operate a height of about 2 5 meters Also it should be correctly a 3 tone sound is emitted every 12 placed in an area that does not obstruct the hours sound Beacon WARNING There is a two position ON OFF jumper on the All 4 mounting screws must be used ...

Страница 2: ... the SE SERVICE signal that prevents the siren from sounding during the installation It must be connected during the connection procedure and disconnected from the panel side after the installation has finished The remaining 2 cables are used for connecting the T1 T2 TAMPER inputs of the siren to the Ζ8 zone TAMPER of the panel This method permits the siren to sound if tampered with and will also ...

Страница 3: ...BS 413 siren to the BS 468 panel Remove this cable after the installation has finished 24_H C C 12V ALARM RELAY SIRENS NO C NC TC EXT AUTO Remove this cable after the installation has finished Siren BS 413 Figure 2 Connecting a BS 413 siren to the BS 418 panel 921413000_09_008 Page 3 from 4 SE T1 T2 ST SE T1 T2 FL ...

Страница 4: ...tructions included in official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re setting done by a third party unless Olympia Electronics has fully agreed to them in writing Products that have been damaged can be returned to the premises of our company for repair or replacement as long as the warranty period is valid Olympia Electronics res...

Отзывы: