background image

921413000_09_008

Page

 1

 from

 

4

1

3,6

-

14,8

V

 

DC

6mA

Bayblend FR3010,

 

clear

 

polycarbonate (red

)

USAGE

BATTERY TYPE

For external use

12V/1,3Ah  Pb (

sealed lead-acid

) (

not included)

IP20

115 dB / 1m

-10 

 60  C

o

έως

Up to 95% 

2 years (6 months for A-989 battery)

1700gr.

290x95x190mm

BS-413

EN 5

0130-

4, EN 55022, EN 60950-1

TECHNICAL CHARACTERISTICS

RELATIVE HUMIDITY
CONSTRUCTION MATERIAL

WEIGHT

EXTERNAL DIAMENSIONS

GUARANTEE

OPERATION VOLTAGE
QUIESCENT CONSUMPTION
SOUND LEVEL

PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE

DEGREES OF COVER PROTECTION

Autonomous electronic siren 

with beacon

 

for burglar alarm panels

GENERAL

tampered with.

The BS-413 alarm siren is of robust design and 

If you require, the siren to also be activated if the 

can  be  used  with  conventional  burglar  alarm 

siren  is  dismounted  from  the  wall.  you  must 

panels such as the

 BS-468. 

It has a red beacon 

connect the T1, T2 (TAMPER) inputs.

that  blinks  when  the  siren  is  activated  and  a 

In  case  of  maintenance  or  if  the  siren  is  moved 

piezo  speaker  that  produces  a  sound  level  of 

from  it’s  mounting  position,  the 

 

SE

  (

Service

1

15

dB 

at 1 meter

.

input

 

of the siren must be connected to the 

(-)

 

of 

The  incorporated  tamper  mechanism  protects 

the panel and the panel must be set to OFF.

the  siren  from  unauthorized  access  when  the 
cables  are  cut,  the  cover  is  removed  or  when 

Battery

the siren is unmounted from the wall.

If  the  battery  has  not  been  connected  then  the 
siren  produces  a  single  tone  sound  every  1 

Mounting

second.

It is mounted externally on a flat surface and at 

Whereas  if  the  battery  does  not  operate 

a  height  of  about  2,5  meters. Also  it  should  be 

correctly,  a  3  tone  sound  is  emitted  every  12 

placed  in  an  area  that  does  not  obstruct  the 

hours.

sound

Beacon

WARNING

!!! 

There is a two position (ON, OFF) jumper on the 

All 4 mounting screws must be used

siren  which  is  marked 

(LED  FLASΗ). 

If  a  link  is 

placed  on  the 

(ON) 

position,  the  beacon  blinks 

Connection

every  4  seconds  in  the  quiescent  state.  If  no 

The connection between the siren and the 

BS-

jumper is placed then the beacon is OFF during 

468 

panel is shown on figure 1

.

the quiescent state and blinks during the alarm.

After finishing with the connections, connect the 
battery cables, install the internal cover and the 

Start 

signal

front fascia of the siren by installing the screws 

There  is  also  another  2  position  jumper  marked 

 

on  the  bottom  side.

 

Finally  remove  the  cable 

(TRIGGER) 

with the positions

 (-) 

and

 (+). 

connected to the 

SE

 

(Service) 

of the siren from 

This  jumper  sets  if  the  trigger  in  positive  or 

the 

(-) 

of the panel

The siren will sound once to 

negative

.  Α 

positive  trigger  means  that  the 

ST 

indicate that it is ready to operate and receive a 

(

START

)  signal  must  be  a  positive  voltage  for 

command  from the panel.

  

the siren to be activated.

The siren now charges the battery and is ready 
to accept an ALARM signal from the panel or if 
the  cables  are  cut.

 

If  we  connect  the 

Τ1,

 

Τ2

 

(TAMPER) 

signals

 

then it will be activated if it is 

Thank you for your trust in our products  

Olympia Electronics -  European manufacturer

Содержание BS-413

Страница 1: ...en the siren produces a single tone sound every 1 Mounting second It is mounted externally on a flat surface and at Whereas if the battery does not operate a height of about 2 5 meters Also it should be correctly a 3 tone sound is emitted every 12 placed in an area that does not obstruct the hours sound Beacon WARNING There is a two position ON OFF jumper on the All 4 mounting screws must be used ...

Страница 2: ... the SE SERVICE signal that prevents the siren from sounding during the installation It must be connected during the connection procedure and disconnected from the panel side after the installation has finished The remaining 2 cables are used for connecting the T1 T2 TAMPER inputs of the siren to the Ζ8 zone TAMPER of the panel This method permits the siren to sound if tampered with and will also ...

Страница 3: ...BS 413 siren to the BS 468 panel Remove this cable after the installation has finished 24_H C C 12V ALARM RELAY SIRENS NO C NC TC EXT AUTO Remove this cable after the installation has finished Siren BS 413 Figure 2 Connecting a BS 413 siren to the BS 418 panel 921413000_09_008 Page 3 from 4 SE T1 T2 ST SE T1 T2 FL ...

Страница 4: ...tructions included in official documents given by Olympia Electronics or if the buyer modifies the goods provided or has any repairs or re setting done by a third party unless Olympia Electronics has fully agreed to them in writing Products that have been damaged can be returned to the premises of our company for repair or replacement as long as the warranty period is valid Olympia Electronics res...

Отзывы: