background image

LED

OFF ON  

LED

OFF ON  

LED’s are enabled

LED’s are disabled

High sensitivity

. 2 

pulses for stable

environment.

Note: For long detection range set the switch
           in OFF position.

PIR

PIR

OFF ON  

OFF ON  

Low sensitivity

. 3 

pulses for

harsh environment

.

MW low range control according to the 
room size with detection range for 

m

 

5 - 9 .

Immunity to an animal up to 25 kg

``OR`` operation. The alarm signal 
(relay activation) occurred when one 
of the sensors signal (PIR & MW) is 
present.

MW

PET

Α/Ο

MW

PET

Α/Ο

OFF ON  

OFF ON  

OFF ON  

OFF ON  

OFF ON  

OFF ON  

PIR adjustment

Use the Potentiometer marked 

"PIR" 

to adjust the

detection sensitivity between 15% and 100%, 
according to walk test in the protected area.
(Factory setting is 57%)
Rotate the potentiometer clockwise to increase 
range, counter-clockwise to decrease range.

MW high range control according to the 
room size with detection range for 

m

10 - 18 .

Immunity to an animal up to 15 kg

``AND`` operation. The alarm signal 
occurred only when both sensor signals
(PIR and MW) are present at the same
time. 

Description of the detector adjustments

Connection terminals

indication
LED’s

Sensor

Μ

W sensitivity

control

LED
PIR

MW

MW

PET

A/O

-12V+ TAMP EOL RELAY

PIR ALARM DOP

PIR

PIR range
control

Microswitches

Microswitche’s operation

Selecting mounting location

The  detector  must  be  installed    in  areas  that  can  cover  the 
larger  area  as  possible.  Avoid  locations  that  can  cause  false 
alarms. These locations are:

- Facing direct sunlight.
- Facing areas that may change temperature rapidly.
- Areas where there are air ducts or substantial airflows.
- Avoid screen, curtain that may block detection area.
- Do not install outdoors.

The detector can either be wall or corner mounted. If ceiling or 
special wall mounting is required, use the optional bracket base 
with the included parts (BASE-401). 
Refer to bracket description. (See fig. 4)

Down and side view

Figure

 3

TAMPER
switch

Page 2 from 3

SENSITIVITY CONTROL

Position  the  potentiometer 

"MW" 

at  min-scale  firstly,

then, along with walk testing, turn to mid-scale or max-
scale  gradually  until  you  get  detection  at  the  longest 
distance  for  the  required  detection  range.
Rotate the potentiometer clockwise to increase range, 
counter-clockwise to decrease range.