025-000533 Rev X6
6
www.olsontech.com
Technical Specifications
Typical Models*
115 116 117 118 119 120 121 122 123 124 221 419
Number of Outputs
1 1 1 1 1 1 1 1 1 1 2 4
Fixed Output Power (dBm)
15 16 17 18 19 20 21 22 23 24 21 19
Power Range (dB)
-10 to +10
Max Alarm (dBm)
10
Input
Power
Min Alarm (dBm)
-10
Wavelength (nm)
1540 to 1560
Output Stability (dB)
±
0.3
0dBm Input (dB)
≤
4.5
≤
5.0
≤
5.3
Noise
Figure
+6dBm Input (dB)
≤
5.5
≤
6.0
≤
6.5
Polarization (dB)
0.2dB
Polarization-Mode
Dispersion (ps)
0.5ps
Reflection Loss (dB)
40dB Minimum
Optical Connector
SC/APC Standard
Network Management Interface
RS-232
Power (W)
50W Maximum
Voltage (V
AC
)
85 to 264
Voltage (V
DC
) -48
Typical
Working Temperature (°C)
+5 to 45
Storage Temperature (°C)
0 to +55
Dimensions
19" x 15" x 1.75" (483mm x 381mm x 44mm)
Contact factory for other options
Figure 4 - Typical CATV CNR Degradation