background image

PAGE 6

1.4 - Health & Safety Cont.

Take care as the packaging material can contain nails and other sharp pieces of metal, which can cause injury 
to you and the stove. Take care that the nylon and other wrapping materials do not get in children’s hands, 
as they can cause suffocation. Carefully collect the packaging materials mentioned above, and take them to 
the local waste disposal site.

The stove is painted in high temperature paint and high quality heat resistant lacquer that gains its final 
stability when heating up for the first time. The smell at the first heating up derives from the evaporation of 
the protection lacquer in the paint. So the heated room must be carefully ventilated from time to time (every 
1-2 hours). The smell will stop after a while of burning. 

Do not put anything on the stove before the first heating 
up  and  do  not  touch  its  surface  to  prevent  damage  of 
lacquering. Use protective gloves for your own protection 
and  for  the  sake  of  the  intactness  of  the  lacquering.  The 
doors of the stove should be kept slightly open during the 
first heating up so the insulation cord does not stick to the 
front of the stove.

Due to its general technical approval, the stove can be used simultaneously with an approved ventilation 
system without additional safety device. Equipped with a self-closing combustion chamber door, the stove 
is approved to be connected to multiflue chimneys provided that it operates with a room-air dependent 
combustion-air supply. Room-air independent operation requires that the exhaust gases of the stove be 
discharged through a single flue  chimney or the exhaust duct of a single flue air-exhaust chimney. Exhaust 
gases may also be discharged into multi flue exhaust gas systems if all connected stoves are part of the same 
utilisation  unit/action  range  of  the  ventilation  system.  Individual  differences  can  be  discussed  with  your 
fitter/engineer

Содержание PENMAN PULAR

Страница 1: ...INSTRUCTION MANUAL OLSBERG PULAR COMPACT DIN EN 13240 DIN 18897 raumluftunabh ngig DIBt Bauaufsichtliche Zulassung 15a BV G INSTALLATION INSTRUCTIONS OLSBERG PULAR CYLINDRICAL STOVE...

Страница 2: ...PAGE 2...

Страница 3: ...10 3 1 General Information 3 2 Suitable Fuels 3 3 Reducing Emissions 3 4 Lighting the for the first time 3 5 After Use Maintining the perfect burn 3 6 Operating The Air Slide Valve 3 7 Operating the...

Страница 4: ...e the rest of the fuel burns up in the second phase of the combustion process This process is characterized by strongly glowing embers with no or only smaller temporary flames Optimal and environmenta...

Страница 5: ...Pa can lead to uncontrollable combustion process that can damage the appliance itself the connecting pipe and the chimney sweep or a competent expert about finding a solution In such cases we recommen...

Страница 6: ...ch its surface to prevent damage of lacquering Use protective gloves for your own protection and for the sake of the intactness of the lacquering The doors of the stove should be kept slightly open du...

Страница 7: ...ditions Authorization of the stove as independent of the air in the room and insulated air inlet from outside are among these conditions It is important to consult a competent chimney sweep or expert...

Страница 8: ...eeve and the sealing cover Decide where the stove is to be installed There must be no objects made of combustible materials within a dis tance of 80 cm of the stove s radiation area measured from the...

Страница 9: ...horizontal connecting valves Incase of stoves with a capacity of 6kW the minimum length of the vertical connecting pipe is 50cm We recommend the use of an insert with a double wall for connecting to t...

Страница 10: ...uel according to heat demand The heating value of 1kg of dry wood is 4 4 5kW This means you can place about 2 4kg of wood into a stove of 8kW capacity every hour When burning wood if a lower capacity...

Страница 11: ...ant to load more fuel and only if the previous amount has burned down to embers The condition of proper operation of the stove is the appropriate chimney draught feed pressure This is considerably dep...

Страница 12: ...g lever for the fire grate With the help of the operating lever the fire grate can be opened or closed to move the ash from the combus tion chamber to the ash pan by pushing the fire grate back and fo...

Страница 13: ...Regulation of combustion air Position of operating lever II Ignition position max heat output I Nominal heat output with billet wood I Nominal heat output with wood briquettes 0 Obtain glow As the se...

Страница 14: ...Use only a small amount of fuel at first Use only a small amount of fuel when reloading Riddle Grate What are the causes There is no proper draught at heating up Chimney or stove pipe is not closed pr...

Страница 15: ...re made of materials of excellent quality There s continuous control through the manufacturing procedures and the finished stove is subjected to stringent quality control 5 0 SPECIAL NOTES WHAT FREQUE...

Страница 16: ...PAGE 16 APPENDIX 1 DIMENSIONAL DRAWINGS 147 147 1218 472 472...

Страница 17: ...PAGE 17 BLANK...

Страница 18: ...PAGE 18 BLANK...

Страница 19: ......

Страница 20: ...Brought to you by Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN Tel 01204 868 550 Fax 01204 868 551 Email sales percydoughty com www visionfires co uk...

Отзывы: