LEVANA 2.0 6 kW
LEVANA 2.0 8 kW
LEVANA AQUA 2.0
ARINA 2.0
INARA 2.0
GB
6 Product data sheet
Stove product data sheet
Technical Documentation according to Regulation (EU) 2015/1185 for solid fuel local space heaters (with additional parameter of Technical Documentation according to Regulation (EU)2015/1186)
Model identifi er
LEVANA 2.0, 43-248
ARINA 2.0, 43-256
INARA 2.0, 43-266
Manufacturer| Adress
Olsberg GmbH | Hüttenstraße 38 | 59939 Olsberg | Deutschland
Test reports
PL-21062-1-P
Test laboratory
TU Wien, Getreidemarkt 9/166, A-1060 Wien
Harmonized Standards
EN 14785:2006-09 /EN 16510-1:2018-07 /EN
16510-2-6:2014-07
Other technical standards and specifi cations
CEN/TS 15883:2010
Indirect heating function [yes / no]
no
Direct heat output
6,0 kW
Indirect heat output
1
0,0 kW
Characteristics when operating with the preferred fuel
Seasonal space heating energy effi ciency ηs [%]:
77,0 %
Energy effi ciency index (EEI):
117
Energy effi ciency class
A+
Fuel
Preferred
fuel (only
one):
2
:
Other suitable
fuel (s)
3
:
ηs
[x%]:
Emissions at nominal
heat output
Emissions at minimum
heat output
4
PM OGC
CO
NOx PM OGC CO
NOx
[x] mg/Nm3 (13 % O2)
[x] mg/Nm3 (13 % O2)
Wood logs, moisture content ≤ 25 %
no
no
Compressed wood, moisture content < 12 %
yes
yes
77
6
6
157
142
Lignite briquettes
no
no
Other fuels
5
no
no
Specifi cation
Item
Value
Unit
nominal heat output
P
nom
6,0
kW
minimum heat output (partial load heat output according to standard)
P
min
0,0
kW
Auxiliary power consumption at nominal heat output
el
max
0,000
kW
Auxiliary power consumption at minimum heat output
el
min
0,000
kW
Auxiliary power consumption in standby mode
el
SB
0,000
kW
Permanent pilot fl ame power requirement (if applicable)
P
pilot
N. A.
kW
Specifi c precautions for assembly, installation or maintenance
Fire protection and safety distances such as distances to combus-
tible building materials, among others, must be observed under all
circumstances!
A suffi cient supply of combustion air for the appliance must be gua-
ranteed at all times. Air-suction systems can interfere with the com-
bustion air supply!
Fuel effi ciency at nominal heat output (Based on the net calorifi c value (NCV)
η
th,nom
89,0
%
Fuel effi ciency at minimum heat output (Based on the net calorifi c value (NCV)
η
th,min
0,0
%
Type of heat output/room temperature control (select one):
Single-stage heat output, no room temperature control
no
two or more manual stages, no room temperature control
no
with mechanic thermostat room tem-perature control
no
with electronic room temperature con-trol
no
with electronic room temperature con-trol plus day timer
no
with electronic room temperature con-trol plus week timer
no
Other control options (multiple selection possible)
room temperature control, with pres-ence detection
no
room temperature control, with open window detection
no
with distance control option
no
1
No entry is made for fi replaces without water-bearing components.
2
Values for the annual effi ciency and emissions are to be given here for the preferred fuel.
3
Values for annual fuel effi ciency and emissions are to be given here for all other, other suitable fuels.
4
Corresponds to the partial load heat output according to EN 16510
5
Wood-like biomass, non-wood-like biomass, anthracite and dry steam coal, hard coal coke, low-temperature coke, bituminous coal, peat briquettes, briquettes made
from a mixture of fossil fuels, other fossil fuels, briquettes made from a mixture of biomass and fossil fuels, other mixture of biomass and solid fuels
Product data sheet
We reserve the right to make technical changes
93
| 154