20
Installation Instructions
•
Delivery and packaging
To facilitate transport and handling, the heater
cabinet (with built-in heating elements) and the
bricks (SP36, SP38) are packaged separately.
The packaging has be limited to the minimum nec-
essary for safe transport and is made entirely of
recyclable materials.
fig.1
•
Electrical connection
The storage heater is connected to a single-phase
circuit.
Voltage: 1/N/PE ~ 230V
Charge period: 8h
According to safety instructions, each electrical cir-
cuit must be protected by a circuit breaker with an
all-pole contact opening of 3mm minimum.
•
Heater positioning, minimum clearances
The heater is to be positioned with the feet pre-
mounted against a load-bearing wall and secured
according to this instruction and using the fixing
materials provided.
It is preferable to place the heater under a window
so that the cold air in this vicinity can be warmed,
causing natural convection.
The floor and/or the wall must be able to take the
weight of the heater. Please, therefore, note care-
fully the weights given in the Technical Data sec-
tion of this instruction. If in doubt, consult a building
engineer or architect.
The minimum clearances in fig.2 are to be ad-
hered to when positioning this heater.
To facilitate installation we recommend keep-
ing a distance of 150mm min. to the sides of
the heater.
fig.2
•
Rating label, manufacturing (batch) number
The rating label (fig.3) contains all the data specific
to the heater model. The rating label is found on
the bottom right of the heater rear panel.
The manufacturing, or batch number is on a sepa-
rate label on the right hand side of the heater plinth
(remove front panel).
The model and batch numbers are important for
repair and spare parts purposes.
model
weight
fig.3
14/691-3 14/695-3
14/692-3
14/692-4
14/702-3
14/696-4
14/693-3
14/693-4
14/703-3
14/694-3
14/694-4
14/704-3
A
125
235
345
395
505
725
B
110
110
110
140
140
140
L
345
455
565
675
785 1005