A 10 AMP,220 Volt, 50 Hz circ
uit with a properly
grounded outlet is required. Preferably, the fireplace
will be on a dedicated circuit as other appliances on
the same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is in operation.
The unit comes standard with a three wire cord, exiting
from the rear of the fireplace. Plan the installation to
avoid the use of an extension cord. If an extension cord
must be used, it must be a minimum 14AWG, three wire
with grounding type plug connector and rated not less
than 1875 Watts. The extension cord shall not be more
than 20 feet in length.
WARNING: Electrical outlet wiring
must comply with local building codes
and other applicable regulations to
reduce the risk of fire, electrical shock
and injury to persons.
WARNING: Do not use this fireplace if
any part of it has been under water.
Immediately call a qualified service
technician to inspect the fireplace and
replace any part of the electrical system.
WARNING: This fireplace comes with
an ES. In case the fireplace is not
operating disconnect the power and reset
the ES. If the fireplace is still not
operating immediately call a qualified
service technician to inspect the
fireplace.
Service Instructions
WARNING: Disconnect power before
attempting any maintenance or cleaning
to reduce the risk of fire, electrical shock
or personal injury.
Maintenance of Motors
The motors used on the fan and the flame generator
assembly are prelubricated for extended bearing life
and require no further lubrication. However, periodic
cleaning/vacuuming of the fan/heater unit is recom-
mended.
WARNING: Make sure that the power is
turned off before proceeding.
Replacing the Light Bulbs
4
1.Under no circumstances should this product be
operated with missing or broken glass.
2.Do not strike or slam the glass.
3.Do not use abrasive cleaners to clean the glass.
4.This product uses tempered glass. Replacement
should be carried out by a qualified service person.
Glass information
Electrical Connection